ASTM A213 TP304N / UNS S30451 seamless boiler, superheater and heat-exchanger tube — nitrogen-strengthened 18-8 with N 0.10–0.16%, Cr 18.0–20.0%, Ni 8.0–11.0%, C ≤0.08%, and a Table 4 floor of 80/35 ksi with hardness max 192 HBW / 90 HRB. SHH STEEL supplies cold-finished and hot-finished seamless tube with EN 10204 3.1 MTCs.
Grade
TP304N / UNS S30451
Standard
ASTM A213 / A213M
Product form
Seamless boiler / superheater / heat-exchanger tube (cold-finished and hot-finished)
Size
Typical OD × min wall (or average wall) within ~1/8 in. [3.2 mm] ID to 5 in. [127 mm] OD and ~0.015–0.500 in. [0.4–12.7 mm] wall; other diameters by agreement
Share:
Overview
Chemical Composition
Mechanical Properties
Specification
Equivalent Grades
Heat Treatment
Corrosion Resistance
Applications
Weldability
Surface Finishes
Inspection and Testing
Packaging and Shipping
Why Choose SHH STEEL
Supply Capability
FAQ
Conclusion

What is ASTM A213 TP304N Stainless Steel Tube

ASTM A213 / A213M covers seamless ferritic and austenitic alloy-steel boiler, superheater, and heat-exchanger tubes. Grade TP304N is the nitrogen-strengthened sister of the familiar 18-8 TP304 listing, carried under UNS S30451 with a mandatory nitrogen band of 0.10–0.16% on the melt. That nitrogen floor is what lifts Table 4 tensile acceptance to 80 ksi [550 MPa] and yield to 35 ksi [240 MPa] — five ksi above the TP304 pair — while chromium and nickel stay in the same 18.0–20.0% / 8.0–11.0% windows and carbon remains ≤0.08%. Writing “304N tube” on a BOM still needs the A213 (or separate ASME SA-213) callout so wall basis, hardness, and marking clauses are contractual.

SHH STEEL can supply ASTM A213 TP304N stainless steel tube as seamless cold-finished and hot-finished product in the usual boiler and heat-exchanger OD × wall / BWG band, shipped with EN 10204 3.1 mill test certificates that report the full stainless-table ladle chemistry — including the nitrogen result — and the Table 4 tensile and hardness set. Dual A213 / SA-213 marking is available only when the purchase order asks for both independent standards on the stencil. Browse the nitrogen and 304-family grades on the A213/A213M hub.

Shop names such as 304N, S30451, or “nitrogen 304 HX tube” do not replace the ASTM grade on the MTC. Sister pages under the same product standard include A213 TP304, A213 TP304LN, A213 TP304L, A213 TP304H, and A213 TP316N. A213 is seamless tube only — cold-finished versus hot-finished is the process choice, not a WLD or HCW manufacturing-type letter.

Chemical Composition of A213 TP304N

Two chemistry layers matter for TP304N under ASTM A213. Melting (heat or ladle) analysis is mandatory for every heat under the stainless chemistry table; product analysis on finished tube applies only when Supplementary Requirement wording or the purchase order invokes it through ASTM A1016/A1016M, with product-analysis tolerances typically taken from ASTM A480/A480M Table A1.1. The nitrogen analysis method itself is a matter of agreement between purchaser and producer (Footnote B in the public table text) — put the agreed method on the PO when N reporting must follow a named technique.

The tables below reproduce the melt limits for TP304N / UNS S30451 and the product-analysis limits that result from applying A480 Table A1.1 tolerances. Values are maximum unless a range is shown; an ellipsis (…) means the ordered edition sets no requirement for that element.

Melting analysis (heat / ladle analysis)

Element TP304N (UNS S30451) melting analysis
Carbon (C) ≤ 0.08
Manganese (Mn) ≤ 2.00
Phosphorus (P) ≤ 0.045
Sulfur (S) ≤ 0.030
Silicon (Si) ≤ 1.00
Chromium (Cr) 18.0 – 20.0
Nickel (Ni) 8.0 – 11.0
Molybdenum (Mo) … (no requirement)
Nitrogen (N) 0.10 – 0.16

Source: ASTM A213/A213M stainless chemistry table for Grade TP304N / UNS S30451 (public mill / specification PDF excerpt cross-checked). Confirm the ordered edition on the purchase order before treating any secondary catalogue as the acceptance text. Stainless table number is edition-dependent (Table 2 in later editions; Table 1 in older ones).

Product analysis — A480/A480M Table A1.1 tolerances applied

Element Melting Tolerance (A480 A1.1) Product analysis limit
Carbon (C) ≤ 0.08 0.01 over ≤ 0.09
Manganese (Mn) ≤ 2.00 0.04 over ≤ 2.04
Phosphorus (P) ≤ 0.045 0.010 over ≤ 0.055
Sulfur (S) ≤ 0.030 0.005 over ≤ 0.035
Silicon (Si) ≤ 1.00 0.05 over ≤ 1.05
Chromium (Cr) 18.0 – 20.0 0.20 under / over 17.80 – 20.20
Nickel (Ni) 8.0 – 11.0 0.10 under / 0.15 over 7.90 – 11.15
Nitrogen (N) 0.10 – 0.16 0.01 under / 0.02 over 0.09 – 0.18

Read the nitrogen line first: the 0.10–0.16% band is the entire reason TP304N exists as a separate grade from A213 TP304. Chromium and nickel stay classic 18-8; carbon stays ≤0.08%, so TP304N is not an L-grade substitute for as-welded intergranular duty — that conversation belongs to A213 TP304LN. Molybdenum remains a no-requirement ellipsis; chloride-heavy exchangers still step to the TP316N / TP316L family.

When product analysis is ordered, finished tube may read up to C 0.09%, Mn 2.04%, P 0.055%, S 0.035%, and Si 1.05%, with Cr 17.80–20.20%, Ni 7.90–11.15%, and N 0.09–0.18%. Those are the only product limits we quote from the A480 A1.1 path for this grade. Put any tighter project nitrogen floor or sulfur ceiling on the purchase order before the heat is selected.

Mechanical Properties of A213 TP304N

ASTM A213 Table 4 sets the tensile acceptance floor for TP304N at 80 ksi [550 MPa] tensile strength and 35 ksi [240 MPa] yield strength (0.2% offset), with elongation of 35% minimum in 2 in. or 50 mm. Hardness is capped at 192 HBW / 200 HV or 90 HRB — the same hardness ceiling as TP304, but on a higher strength pair. That combination is the commercial point of the grade: nitrogen raises the strength floor without rewriting the hardness or elongation story of the 18-8 family.

Property TP304N requirement (Table 4)
Tensile strength, min 80 ksi [550 MPa]
Yield strength (0.2% offset), min 35 ksi [240 MPa]
Elongation in 2 in. or 50 mm, min 35%
Hardness, max 192 HBW / 200 HV or 90 HRB

Source: ASTM A213/A213M Table 4 for TP304N / UNS S30451 (public specification PDF excerpt). Mechanical property requirements do not apply to tubing smaller than 1/8 in. [3.2 mm] inside diameter or thinner than 0.015 in. [0.4 mm] wall. Flattening and flaring tests sit beside tension and hardness on a lot basis.

Design calculations should use the 80/35 ksi Table 4 pair unless the purchase order states higher guaranteed values the mill has accepted in writing. Do not assume a TP304 certificate automatically clears TP304N — a heat without the nitrogen band and without the higher tensile floor is a different grade. When low-carbon as-welded IGC resistance is also required, open A213 TP304LN rather than stretching standard-carbon TP304N.

Dimensions and Tolerances

Dimensional supply for ASTM A213 TP304N is tube language — outside diameter × wall thickness (minimum wall or average wall) and, commercially, BWG / gauge — not ASME B36.19 pipe schedules as the primary size story. Usual sizes under A213 run from about 1/8 in. [3.2 mm] inside diameter to 5 in. [127 mm] outside diameter, with minimum wall from about 0.015 to 0.500 in. [0.4 to 12.7 mm]; other diameters may be furnished when all other requirements are met. State on the purchase order whether wall is minimum or average, because that choice changes how the mill reads A1016 tolerances and how the designer reads remaining wall after fabrication.

Outside-diameter and wall variations follow ASTM A1016/A1016M as invoked by A213. Cold-finished tubes commonly hold tighter OD control; hot-finished tubes allow wider OD and wall windows. Permissible variations from a specified average wall for cold-finished tube are often summarized as ±10% of the specified average wall, while minimum-wall product is accepted to the A1016 minimum-wall tables. Confirm the exact A1016 rows for the OD and finish route on the ordered edition.

Item Typical A213 TP304N dimensional practice
Product form Seamless only (cold-finished or hot-finished)
Usual size band ~1/8 in. [3.2 mm] ID to 5 in. [127 mm] OD; wall ~0.015–0.500 in. [0.4–12.7 mm] min (or average wall if PO says so)
Wall basis Minimum wall (default commercial practice) or average wall when specified
OD / wall tolerances Per ASTM A1016/A1016M for the finish route and size; cold-finished average wall often ±10%
Length Cut lengths for HX / boiler bundles, or mill random lengths by agreement
Secondary size note ASME B36.19 schedules may appear only as a buyer cross-reference — not as the primary A213 size callout

Put the cut list, U-bend or straight-tube preference, and end preparation on the enquiry. Minimum wall is a first-class A213 concept: if the datasheet assumes average wall, say so explicitly before the heat is rolled.

Equivalent Grades

Equivalence language around nitrogen-strengthened 304 tube is often looser than a boiler or heat-exchanger purchase order can afford. ASTM A213 Grade TP304N / UNS S30451 is the governing designation for this article; EN 1.4315 and related wrought names point to similar chemistry families but are not automatic substitutes on an A213 mill test certificate. When a datasheet says “equivalent to 304N,” confirm which product standard, tensile/hardness table, and heat-treatment clause the mill will actually certify.

Designation Notes
ASTM A213 / A213M Grade TP304N Governing ASTM seamless boiler / HX tube product standard for this article
UNS S30451 Unified number listed in the stainless chemistry table
ASME SA-213 TP304N Separate ASME Code Book adoption — dual-mark only when the PO asks
EN 1.4315 (approx.) Approximate wrought stainless designation; order EN tube forms under the relevant EN tube specs
Related plate A240 / SA240 flat product in the same UNS family — order plate and tube under their own product standards

ASME SA-213 TP304N is a separate Code Book adoption; dual A213/SA-213 marking is a purchase-order option. Compare TP304, TP304LN, and TP316N on their own ASTM A213 pages before swapping nitrogen grades inside a tube bundle.

Heat Treatment and Delivery Condition

TP304N under ASTM A213 is furnished solution treated at a minimum of 1900 °F [1040 °C], then quenched in water or cooled rapidly by other means at a rate sufficient to prevent carbide reprecipitation. That heat-treatment row (Table 3 in the public PDF excerpt) applies to both cold-finished and hot-finished seamless tube. Nitrogen must stay in solid solution after the anneal; under-cooling or skipping the quench can leave a structure that loses the strength benefit the grade was ordered for.

Cold-finished versus hot-finished is a process and dimensional route, not a substitute for the anneal. Delivery condition for SHH STEEL TP304N is solution annealed and pickled (or bright annealed by agreement), with heat-treatment temperature and quench method stated on the EN 10204 3.1 certificate. Straightening, cutting, and end finishing follow heat treatment.

When Supplementary Requirement language for intergranular-corrosion capability is ordered, the corrosion test report travels with the heat-treatment record. H-grade grain-size rules do not rewrite the TP304N path — use A213 TP304H when the datasheet calls for H-grade carbon and grain-size controls, or A213 UNS S30432 when Cu–Nb–N USC boiler framing is required.

Corrosion Resistance

TP304N’s chromium-rich passive film behaves like other 18-8 austenitics in oxidizing process fluids, clean steam-side and water-side duties, and many organic media that do not lean heavily on chlorides. Nitrogen at 0.10–0.16% is primarily a strength tool under A213; it is not a molybdenum substitute for chloride pitting. In chloride-bearing cooling circuits and brine-leaning exchangers, buyers usually step to A213 TP316N or A213 TP316L.

Intergranular corrosion risk after tube-to-tubesheet welding is still a carbon story: standard-carbon TP304N (C ≤0.08%) can sensitize the same way TP304 can. When as-welded IGC resistance is the driver, order A213 TP304LN or dual TP304N/TP304LN on qualifying heats, or invoke a contractual A262 Practice E Supplementary Requirement. ASTM A213 itself does not publish a corrosion-rate table for TP304N.

Applications of A213 TP304N Tube

Buyers specify TP304N when the tube datasheet needs the higher 80/35 ksi floor of a nitrogen-strengthened 18-8 without moving into molybdenum grades or specialty Cu–Nb alloys. Typical homes are higher-pressure heat-exchanger circuits, structural or thin-wall HX designs that lean on yield, and process exchangers where the fluid is still in TP304’s corrosion comfort zone but the mechanical design is not.

Application area Typical use of TP304N tube Selection note
Higher-pressure HX Seamless tube where the designer needs 80/35 ksi rather than 75/30 ksi Confirm N band on the MTC; do not accept a TP304 cert as a substitute
Boiler / utility exchangers Moderate-temperature steam and water-side tube with nitrogen strengthening For creep-critical H-grade carbon/grain-size open TP304H or S30432
Process chemical HX Oxidizing or mild corrosive media where 18-8 chemistry is accepted Prefer Mo grades if chlorides dominate
Thin-wall / high-yield designs Designs that use the higher yield to reduce wall or raise allowable stress State min vs average wall clearly on the enquiry
As-welded IGC-sensitive joints Usually not the first choice in standard-carbon TP304N Move to TP304LN or dual N/LN

For sister nitrogen and low-carbon options, stay on the A213/A213M hub rather than borrowing A312 pipe paperwork for tube acceptance.

Weldability

TP304N tube welds with matching or near-matching austenitic filler for tube-to-tubesheet joints and fabrication joins. Common practice uses ER308 / ER308L (or equivalent covered electrodes) under a qualified WPS; some fabricators prefer nitrogen-bearing filler when the base metal nitrogen floor must be reflected in the deposit, but that choice belongs to the WPS, not to the A213 product standard. Heat input control, interpass limits, and post-weld cleaning remain the fabricator’s responsibility under the applicable boiler or pressure-vessel code.

Because A213 TP304N is seamless, there is no mill longitudinal weld to radiograph the way welded pipe standards describe. Focus inspection language on tube integrity (hydro or NDE of each length), tube-to-tubesheet joint quality, and any contractual corrosion test on the base metal. For tube that will enter service as-welded in a sensitizing environment, many owners change the base metal to A213 TP304LN rather than relying on weld procedure alone to protect standard-carbon TP304N.

Surface Finishes

Standard mill delivery for ASTM A213 TP304N is solution annealed and pickled, leaving a clean matte finish suitable for most boiler and heat-exchanger tube duty. Bright annealing under protective atmosphere produces a smoother reflective surface used on some clean-process lines and must be called out because it changes the heat-treatment route. Light polish or specified Ra on the bore or OD is a commercial or service-center operation on top of A213 product, not automatic with the grade stamp.

When a fouling-sensitive exchanger specification quotes an Ra maximum on the bore, put it on the tube purchase order with its own acceptance language. SHH STEEL stencils grade and heat treatment as standard requirements; polish, special OD grind, and passivation after fabrication remain commercial extras unless the contract says otherwise. End preparation should be ordered together with finish so receiving inspection shares one acceptance language.

Inspection and Testing

Base ASTM A213 testing for TP304N includes heat analysis (with nitrogen reported), tension tests to the Table 4 80/35 ksi floors, hardness tests to the Table 4 maximum, flattening and flaring tests on a lot basis, and either hydrostatic testing or nondestructive electric testing of each length. The manufacturer may choose hydro versus NDE unless the purchase order fixes the method. Marking includes the ASTM designation, grade, size, heat number, and other clause-required data.

Supplementary Requirements commonly added on TP304N tube orders are summarized below. Invoke them by number or clear purchase-order wording.

Option Purpose
Product analysis Confirms chemistry — including N — on finished tube
Agreed nitrogen analysis method Locks Footnote B method between purchaser and producer
Intergranular corrosion A262 Practice E (or agreed practice) as a contractual Supplementary Requirement
Minimum vs average wall States which wall basis the size callout uses
Fixed hydro or NDE method Removes manufacturer’s option when the end user mandates one route
Third-party inspection / EN 10204 3.2 Witnessed testing and certificate when the project requires it

Ask the mill to state lot identity clearly on the certificate so hardness and tension specimens map cleanly to the bundle you receive, and so the nitrogen result is visibly tied to the heat that made the higher strength floor possible.

Packaging and Shipping

TP304N tube leaves SHH STEEL bundled, capped or end-protected, and tagged for export or domestic delivery according to the length mix and bend form on the order. Bundle tags repeat the ASTM A213 grade, OD × wall (or BWG), heat number, and PO reference so site receiving can check the shipment without opening every certificate packet first. U-bent tubes need extra cradle or case protection so bend radii and legs are not distorted in transit.

Export packing can be bare bundles, wrapped bundles, or wooden-cased lengths for bright-annealed, polished, or small-bore material. We ship under the Incoterms on the order acknowledgement — FOB, CFR, CIF, EXW, or other agreed terms. Inland trucking, bilingual destination marks, or project color coding for bundle tags should be stated on the enquiry beside the metallurgical notes.

Why Choose SHH STEEL

SHH STEEL treats ASTM A213 TP304N as a product standard with an enforceable nitrogen band and an 80/35 ksi tensile floor — not as a catalogue nickname for “stronger 304.” The MTC reports the stainless-table ladle chemistry including nitrogen, the Table 4 tensile/hardness set, and seamless tube identity under A213; dual A213/SA-213 marking is offered only when requested.

We keep the nitrogen-family conversation honest. If as-welded IGC resistance is the real driver, we steer toward A213 TP304LN or dual TP304N/TP304LN. If molybdenum is needed for chlorides, we open A213 TP316N / A213 TP316L. If USC boiler Cu–Nb–N framing is required, we open A213 UNS S30432. The A213/A213M hub is organized the same way — grade by grade under ASTM, seamless tube only.

Lead times combine near-term stock lengths with mill schedules; we say which is which on the quotation. Cut-to-length, U-bending, polish, and third-party inspection are defined extras. The tube that arrives should match the ASTM callout the engineer wrote, with paperwork a third-party inspector can read without translation.

Supply Capability

SHH STEEL can supply ASTM A213 TP304N stainless steel tube against the edition and finish route named on your enquiry. The capability table below summarizes the sizes, finishes, and documents we regularly quote for this nitrogen-strengthened grade, followed by the Stock / Available sizes map buyers ask for when they need a quick sense of what to enquire against.

Item SHH STEEL capability for TP304N
Standard ASTM A213 / A213M (dual SA-213 marking on request) Grade TP304N / UNS S30451
Product form Seamless only — cold-finished and hot-finished
Size Typical OD × min wall (or average wall) in the A213 usual band; other diameters by agreement
Wall / gauge Minimum wall or average wall; BWG / gauge callouts accepted on enquiry
Length Cut-to-length for HX / boiler bundles; mill random by agreement; U-bends on enquiry
Finish Annealed and pickled; bright annealed or light polish by agreement
Testing Tension (80/35 ksi), hardness (max 192 HBW / 90 HRB), flattening, flaring, hydro or NDE per length; full melt chemistry including N on MTC; product analysis / IGC on order
Documents EN 10204 3.1 with full stainless-table chemistry; third-party inspection / 3.2 on request
Trade terms FOB / CFR / CIF / EXW and other agreed Incoterms

Stock / Available sizes

SHH STEEL quotes TP304N tube against a practical stock-and-mill enquiry range rather than a frozen warehouse SKU list. The sizes below are OD × wall / BWG combinations buyers most often request for nitrogen-strengthened HX and boiler tube; availability of any single line on a given week depends on mill drawing and our inbound schedule, so treat the table as a supply map for enquiry — not a guarantee that every line sits on the floor with a published tonnage.

Item Typical stock / enquiry range for TP304N
Outside diameter 12.7, 15.88, 19.05, 25.4, 31.8, 38.1, 50.8, 63.5, 76.2 mm (and other HX/boiler ODs on enquiry; up through the usual A213 ~5 in. [127 mm] band)
Wall / BWG BWG 10–20 class walls and metric min-wall equivalents; lighter and heavier walls by agreement
Common OD × wall examples 19.05 × 1.65 mm; 19.05 × 2.11 mm; 25.4 × 2.11 mm; 25.4 × 2.77 mm; 31.8 × 2.77 mm; 38.1 × 2.77 mm — illustrative sizes, confirm min vs average wall
Length Cut lengths for exchanger bundles; U-bends and straight random lengths on enquiry
Special Non-standard OD/wall, bright anneal, polished bore, agreed N analysis method, and dual A213/SA-213 marking — confirm on enquiry

When you send an enquiry, list OD × wall (or BWG), wall basis (minimum or average), cold-finished or hot-finished preference, quantity or cut list, required marking (A213 alone or dual A213/SA-213), nitrogen analysis expectations, and any Supplementary Requirements. We reply with what we can ship from near-term stock versus what needs a mill run, without inventing fake warehouse codes or tonnage claims.

Send the size list, finish route, quantity or cut lengths, required marking, Supplementary Requirements, and destination on one enquiry. We will confirm chemistry — including the 0.10–0.16% nitrogen band — and tensile/hardness against Table 4, state what ships from near-term availability versus mill production, and keep the offer aligned with ASTM A213 / A213M. Related grades such as A213 TP304, A213 TP304LN, and A213 TP316N sit on the same hub when the datasheet steps sideways.

FAQ

Is ASTM A213 the same as ASME SA-213 for TP304N?
No. ASTM A213 / A213M is the ASTM International product specification for seamless boiler, superheater, and heat-exchanger tubes; ASME SA-213 / SA-213M is the separate ASME Code Book adoption of that grade text. Chemistry and tensile floors align closely for a given referenced edition, but they remain two independent standards. Dual-mark A213/SA-213 tube only when the purchase order asks for both names on the stencil and MTC.
Does ASTM A213 TP304N include welded or HCW tube?
No. ASTM A213 covers seamless tube only. There is no WLD or HCW manufacturing type under this product standard. The process choice for TP304N under A213 is cold-finished versus hot-finished seamless tube, plus the heat-treatment and testing clauses of the ordered edition. If you need welded stainless pipe, that is a different product standard and a different steelspecs page family.
What nitrogen range does ASTM A213 require for TP304N?
TP304N / UNS S30451 carries a mandatory nitrogen band of 0.10–0.16% on the melt analysis. That band is what separates the grade from TP304 and what supports the higher Table 4 tensile floor. The method of nitrogen analysis is a matter of agreement between purchaser and producer under the table’s Footnote B — put the agreed method on the purchase order when reporting technique matters.
TP304N vs TP304 — why order the N grade under A213?
Order TP304N when the datasheet needs the 80 ksi [550 MPa] / 35 ksi [240 MPa] tensile pair rather than TP304’s 75/30 ksi floor, and when the nitrogen band of 0.10–0.16% is acceptable or required. Chromium, nickel, and carbon ceilings otherwise track the same 18-8 family. Do not treat a TP304 certificate as automatic clearance of TP304N — nitrogen and tensile must both match.
TP304N vs TP304LN — which nitrogen grade should I buy?
Order TP304N when standard carbon ≤0.08% is acceptable and the higher 80/35 ksi floor is the driver. Order TP304LN when as-welded intergranular resistance needs the L-grade carbon ceiling (≤0.035%, Footnote D to 0.040%) while nitrogen still supports a 75/30 ksi floor. Dual TP304N/TP304LN is possible only on heats that clear both chemistry windows and both Table 4 rows — ask for it on the PO.
Does A213 Table 4 set a hardness limit for TP304N?
Yes. Table 4 for TP304N lists tensile strength, yield strength, elongation, and a hardness maximum of 192 HBW / 200 HV or 90 HRB. Hardness tests are part of lot acceptance under A213. If a project needs a tighter hardness window than Table 4, write it into the purchase order as an additional requirement rather than assuming the mill will invent one.
Minimum wall vs average wall — which should I order for A213 TP304N?
Order minimum wall when the design and datasheet are written around a guaranteed minimum thickness after tolerance. Order average wall only when the purchase order explicitly allows average-wall product and the designer has accepted that basis. The two readings produce different tube from the same OD × wall line, so put the wall basis on the enquiry before the mill selects tooling and tolerance tables from A1016.
Hydrostatic test vs NDE — which do I get on TP304N tube?
ASTM A213 requires each tube to be hydrostatically tested or nondestructively electrically tested. The manufacturer may choose the method unless the purchase order fixes one. Neither route is an informal upgrade over the other inside the product standard. State the preferred method on the enquiry if your end user or inspector mandates hydro only or a named NDE technique.
What heat treatment does ASTM A213 require for TP304N?
TP304N is solution treated at a minimum of 1900 °F [1040 °C] and then water quenched or rapidly cooled to prevent carbide reprecipitation. Both cold-finished and hot-finished seamless tube follow that heat-treatment requirement. Ask the mill to state anneal temperature and quench method on the EN 10204 3.1 certificate so receiving inspection can clear the heat without chasing verbal confirmations.
Is TP304N better than TP304 in chlorides?
Not as a product-standard claim. Nitrogen strengthens the austenitic matrix; it does not replace molybdenum for chloride pitting and crevice resistance. In seawater-leaning cooling water and many brine exchangers, open TP316N or TP316L on the A213 hub rather than stretching TP304N. ASTM A213 does not publish a chloride ranking table for these grades.
Can you dual-certify ASTM A213 and ASME SA-213 TP304N, or TP304N/TP304LN?
Yes on both axes when the heat and testing support it. Dual A213/SA-213 marking is available when the purchase order requests both independent standards on the stencil and MTC. Dual TP304N/TP304LN is available when ladle chemistry meets the L-grade carbon rules and the nitrogen band, and when tensile plus hardness clear both Table 4 rows. Spell the required marking on the enquiry so the heat is selected correctly.

Conclusion

ASTM A213 TP304N / UNS S30451 is the nitrogen-strengthened 18-8 seamless stainless steel tube grade for boiler, superheater, and heat-exchanger service when the designer needs an 80/35 ksi Table 4 floor and a contractual 0.10–0.16% nitrogen band. SHH STEEL supplies cold-finished and hot-finished seamless tube in the usual OD × wall / BWG band, solution annealed at 1900 °F [1040 °C], tested to Table 4 tensile and hardness limits, and documented on EN 10204 3.1 certificates — with dual SA-213 marking only when the order asks for that separate ASME standard. For sister nitrogen and low-carbon grades, start from the A213/A213M hub, then send your OD × wall list, wall basis, and marking requirements so we can align mill and near-term availability to the ASTM callout.

Contact: admin@steelspecs.com

Contact Us

Quality Steel Needed? Inquire for Offers

Need quality steel for your project? Inquire now to get tailored offers. Our team ensures quick responses, matching your needs with reliable steel solutions. Start your inquiry today.

    *

    *

    *

    *


    Related Products

    SHH STEEL Get Your Steel Quote—Inquire Now for Quick Response
    SHH STEEL Get Your Steel Quote—Inquire Now for Quick Response

      *

      *

      *

      *


      X