ASTM A213 TP317L Stainless Steel Tube
What is ASTM A213 TP317L Stainless Steel Tube
ASTM A213 / A213M is the product specification for seamless ferritic and austenitic alloy-steel boiler, superheater, and heat-exchanger tubes. Grade TP317L / UNS S31703 is the low-carbon partner to A213 TP317: melting carbon is capped at 0.035%, chromium stays at 18.0–20.0%, nickel at 11.0–15.0%, and molybdenum remains in the 3.0–4.0% band that sits a full percentage point above the 316-family Mo window. Table 4 sets tensile at 75 ksi [515 MPa] / 30 ksi [205 MPa] with elongation 35% minimum — one point above the 34% printed for standard TP317 — and hardness max 192 HBW / 90 HRB. Buyers who write “317L HX tube” on a bill of materials still need to name A213 on the purchase order so the mill applies the tube product standard, minimum-wall rules, and the L-grade carbon check together with the elevated Mo floor.
SHH STEEL can supply ASTM A213 TP317L stainless steel tube as seamless cold-finished and hot-finished product in the usual boiler and heat-exchanger OD × wall / BWG band, shipped with EN 10204 3.1 mill test certificates that report the full ladle chemistry — carbon at or below 0.035% and molybdenum inside 3.0–4.0% — plus the Table 4 tensile, elongation, and hardness results. Dual A213 / SA-213 marking is offered only when the purchase order asks for both independent standards. Start from the A213/A213M hub for the rest of the Mo-bearing tube grades.
Commercial shorthand such as 317L, S31703, or “low-carbon high-Mo HX tube” never replaces the ASTM grade on the MTC or stencil. Sister grades under the same ASTM standard include A213 TP317, A213 TP316L, A213 TP317LM, A213 TP317LMN, and A213 TP316. A213 covers seamless tube only — there is no welded or HCW manufacturing type — so cold-finished versus hot-finished seamless route is the finish/process choice.
Chemical Composition of A213 TP317L
Two chemistry layers matter for TP317L under ASTM A213. Melting analysis is mandatory for every heat; product analysis on finished tube applies only when Supplementary Requirement wording or the purchase order invokes it through ASTM A1016/A1016M, with tolerances typically from ASTM A480/A480M Table A1.1. The first line a reviewer should check is carbon ≤0.035% — that is the intentional L-grade ceiling that separates TP317L from TP317’s 0.08% max. The second line is molybdenum 3.0–4.0% with Cr 18.0–20.0% and Ni 11.0–15.0% — the same Mo and Cr–Ni bands as TP317, not the 2–3% Mo / 16–18 Cr / 10–14 Ni window on A213 TP316L. Unlike TP316L, the public A213 stainless table for TP317L does not print Footnote D beside the carbon ceiling; do not import a 0.040% thin-wall path from a 316L checklist unless the ordered edition explicitly says so. Nitrogen appears as an ellipsis (no requirement) in the public table for this grade.
The tables below reproduce the melt limits for TP317L / UNS S31703, the product-analysis limits from A480 Table A1.1 practice, and a short carbon / molybdenum snapshot against TP316L, TP317, and TP317LM. Later A213 editions place austenitic stainless grades in Table 2 (older editions used Table 1); confirm the ordered edition on the purchase order.
Melting analysis (heat / ladle analysis)
| Element | TP317L (UNS S31703) melting analysis |
|---|---|
| Carbon (C) | ≤ 0.035 |
| Manganese (Mn) | ≤ 2.00 |
| Phosphorus (P) | ≤ 0.045 |
| Sulfur (S) | ≤ 0.030 |
| Silicon (Si) | ≤ 1.00 |
| Chromium (Cr) | 18.0 – 20.0 |
| Nickel (Ni) | 11.0 – 15.0 |
| Molybdenum (Mo) | 3.0 – 4.0 |
| Nitrogen (N) | … (no requirement; analysis method by agreement when reported) |
Source: ASTM A213/A213M stainless chemistry table for Grade TP317L / UNS S31703 (public mill / specification PDF excerpt — _ref_a213.txt / A213–13 table text). Confirm the ordered edition. Where ellipses appear, the ordered edition sets no requirement for that element.
Product analysis — A480/A480M Table A1.1 tolerances applied
| Element | Melting | Tolerance (A480 A1.1) | Product analysis limit |
|---|---|---|---|
| Carbon (C) | ≤ 0.035 | 0.01 over | ≤ 0.045 |
| Manganese (Mn) | ≤ 2.00 | 0.04 over | ≤ 2.04 |
| Phosphorus (P) | ≤ 0.045 | 0.010 over | ≤ 0.055 |
| Sulfur (S) | ≤ 0.030 | 0.005 over | ≤ 0.035 |
| Silicon (Si) | ≤ 1.00 | 0.05 over | ≤ 1.05 |
| Chromium (Cr) | 18.0 – 20.0 | 0.20 under / over | 17.80 – 20.20 |
| Nickel (Ni) | 11.0 – 15.0 | 0.15 under / over | 10.85 – 15.15 |
| Molybdenum (Mo) | 3.0 – 4.0 | 0.10 under / over | 2.90 – 4.10 |
Carbon / Mo snapshot — TP316L / TP317 / TP317L / TP317LM
| Element | TP316L (S31603) | TP317 (S31700) | TP317L (S31703) | TP317LM (S31725) |
|---|---|---|---|---|
| C | ≤ 0.035 | ≤ 0.08 | ≤ 0.035 | ≤ 0.03 |
| Cr | 16.0 – 18.0 | 18.0 – 20.0 | 18.0 – 20.0 | 18.0 – 20.0 |
| Ni | 10.0 – 14.0 | 11.0 – 15.0 | 11.0 – 15.0 | 13.5 – 17.5 |
| Mo | 2.00 – 3.00 | 3.0 – 4.0 | 3.0 – 4.0 | 4.0 – 5.0 |
| Table 4 elong. min | 35% | 34% | 35% | 35% |
Read carbon and molybdenum together. A heat at 2.8% Mo can clear TP316L but fails TP317L; a heat at 0.05% C can clear TP317 but fails the L-grade ceiling. Versus A213 TP317, the intentional chemistry change is the lower carbon; versus A213 TP317LM, TP317L stops at Mo 3–4% and Ni 11–15% while LM steps Mo to 4–5% with a higher nickel band. Dual TP317L/TP316L is not a meaningful path: the Mo and Cr–Ni bands do not overlap.
When product analysis is ordered, finished tube may read C ≤0.045%, Mn ≤2.04%, P ≤0.055%, S ≤0.035%, Si ≤1.05%, Cr 17.80–20.20%, Ni 10.85–15.15%, and Mo 2.90–4.10%. Put any tighter project carbon or molybdenum floor on the purchase order before the heat is selected — both digits are intentional for as-welded higher-Mo framing.
Mechanical Properties of A213 TP317L
ASTM A213 Table 4 sets the tensile acceptance floor for TP317L at 75 ksi [515 MPa] tensile strength and 30 ksi [205 MPa] yield strength (0.2% offset), with elongation of 35% minimum in 2 in. or 50 mm and hardness max 192 HBW / 200 HV or 90 HRB. That 75/30 ksi pair matches standard TP317 and sits above the 70/25 ksi floor on TP316L — low carbon here does not force the L-grade tensile step-down that 304L and 316L carry. Receiving checklists must use the TP317L row: elongation 35% (not TP317’s 34%), and tensile 75/30 (not TP316L’s 70/25).
| Property | TP317L requirement (Table 4) |
|---|---|
| Tensile strength, min | 75 ksi [515 MPa] |
| Yield strength (0.2% offset), min | 30 ksi [205 MPa] |
| Elongation in 2 in. or 50 mm, min | 35% |
| Hardness, max | 192 HBW / 200 HV or 90 HRB |
Source: ASTM A213/A213M Table 4 for TP317L / UNS S31703 (public specification PDF excerpt — _ref_a213.txt). Mechanical property requirements do not apply to tubing smaller than 1/8 in. [3.2 mm] inside diameter or thinner than 0.015 in. [0.4 mm] wall. Flattening and flaring tests are also required on a lot basis.
A tensile-and-Mo MTC that omits carbon or reports a 70/25 checklist against a 75/30 grade is incomplete documentation practice for TP317L. When Mo 4–5% is also required, open A213 TP317LM or A213 TP317LMN rather than stretching a 3–4% Mo heat into a higher-Mo story.
Dimensions and Tolerances
Dimensional supply for ASTM A213 TP317L is tube language — OD × wall (minimum or average) and commercially BWG / gauge — not ASME B36.19 pipe schedules as the primary size story. Usual A213 sizes run from about 1/8 in. [3.2 mm] ID to 5 in. [127 mm] OD, with minimum wall about 0.015–0.500 in. [0.4–12.7 mm]; other diameters may be furnished when all other requirements are met. State min versus average wall on the purchase order — boiler and heat-exchanger datasheets almost always assume minimum wall.
OD and wall variations follow ASTM A1016/A1016M as invoked by A213. Cold-finished tubes commonly hold tighter OD control; hot-finished tubes allow wider windows. Cold-finished average-wall product is often summarized as ±10% of the specified average wall; minimum-wall product follows the A1016 minimum-wall tables. Confirm the exact rows for the OD and finish route on the ordered edition.
| Item | Typical A213 TP317L dimensional practice |
|---|---|
| Product form | Seamless only (cold-finished or hot-finished) |
| Usual size band | ~1/8 in. [3.2 mm] ID to 5 in. [127 mm] OD; wall ~0.015–0.500 in. [0.4–12.7 mm] min (or average wall if PO says so) |
| Wall basis | Minimum wall (default commercial practice) or average wall when specified |
| OD / wall tolerances | Per ASTM A1016/A1016M for the finish route and size |
| Length | Cut lengths for HX / boiler bundles, or mill random lengths by agreement |
| Secondary size note | ASME B36.19 schedules only as a buyer-requested cross-reference — not the primary A213 callout |
Put the cut list, U-bend preference, and end preparation on the enquiry. Minimum wall remains a first-class A213 concept regardless of the L-grade carbon and higher molybdenum band.
Equivalent Grades
Equivalence language around 317L tube often collapses plate and tube product forms into one nickname, or treats TP317L as “TP316L with a little more Mo.” ASTM A213 Grade TP317L / UNS S31703 is the governing designation for this article; EN 1.4438 and related wrought names that point to similar higher-Mo low-carbon chemistry families are not automatic substitutes on an A213 MTC.
| Designation | Notes |
|---|---|
| ASTM A213 / A213M Grade TP317L | Governing ASTM seamless boiler / HX tube product standard for this article |
| UNS S31703 | Unified number in the stainless chemistry table |
| ASME SA-213 TP317L | Separate ASME Code Book adoption — dual-mark only when the PO asks |
| Related standard-C | A213 TP317 — same Mo 3–4%, C ≤0.08, elong. 34% |
| Related Mo 2–3% L | A213 TP316L — Mo 2–3%, Cr 16–18 / Ni 10–14, 70/25 ksi |
| Related Mo 4–5% | A213 TP317LM / A213 TP317LMN — separate Mo / Ni / N rows |
| Related plate | A240 / SA240 flat product in the 317L family — order plate and tube under their own standards |
Dual A213/SA-213 marking is a purchase-order option. Compare TP317, TP316L, and the Mo 4–5% sisters on their own ASTM A213 pages before swapping higher-Mo L-grade tube inside a boiler or exchanger list.
Heat Treatment and Delivery Condition
TP317L under ASTM A213 is furnished solution treated at a minimum of 1900 °F [1040 °C], then quenched in water or cooled rapidly by other means. The public heat-treatment table does not print a mandatory ASTM grain-size number for this grade. That heat-treatment row applies to both cold-finished and hot-finished seamless tube. Low carbon plus elevated molybdenum reduce sensitization and pitting risk, but they do not replace the solution anneal — under-cooling can still leave a structure that fails a contractual A262 check even when ladle chemistry looked acceptable on paper.
Cold-finished versus hot-finished is a process and dimensional route, not a substitute for the anneal. Delivery condition for SHH STEEL TP317L is solution annealed and pickled (or bright annealed by agreement), with anneal temperature, quench method, carbon, and molybdenum results on the EN 10204 3.1 certificate. Straightening, cutting, and end finishing follow heat treatment.
Unlike H grades such as A213 TP316H, TP317L has no carbon floor and no grain-size mandate. If a project datasheet asks for ASTM A262 Practice E on 317L, put that Supplementary Requirement on the purchase order rather than assuming base A213 includes it. For Mo 4–5% lists, move to A213 TP317LM instead of relying on procedure alone to stretch a 3–4% Mo heat.
Corrosion Resistance
TP317L’s defining corrosion claim pairs two levers: molybdenum 3.0–4.0% for pitting and crevice resistance relative to the 316L Mo band, and carbon ≤0.035% for as-welded intergranular resistance relative to standard TP317. That pairing makes TP317L the default higher-Mo seamless tube grade when tube-to-tubesheet joints remain as-welded and chloride-leaning aqueous service sits above ordinary 316L PREN. It is still not a duplex or super-austenitic alloy, and it is still not a Mo 4–5% grade — those belong on A213 TP317LM / A213 TP317LMN.
ASTM A213 itself does not publish a corrosion-rate table for TP317L; selection remains engineering judgment against fluid, temperature, velocity, and inspection philosophy. When a specification calls for ASTM A262 Practice E, write that Supplementary Requirement onto the purchase order so the test is contractual. SHH STEEL will not claim TP317L equals Mo 4–5% families or superaustenitics in severe brine — those are separate grade rows with their own chemistries.
Applications of A213 TP317L Tube
Because TP317L combines Mo 3–4% with an L-grade carbon ceiling, it shows up in process heat exchangers and condensers where as-welded tube-to-tubesheet integrity and higher-than-316L molybdenum are both named, chemical-plant tube lists that historically specified 317L, and chloride-leaning aqueous services that still sit inside austenitic (not duplex) selection. The table below pairs typical application areas with a selection note so the grade is chosen for Mo level, weld sequence, and fluid — not only for the familiar “317L” name on the BOM.
| Application area | Typical use of TP317L tube | Selection note |
|---|---|---|
| As-welded higher-Mo process HX | Straight and U-bend tubes when Mo 3–4% + L-carbon are named | Confirm C ≤0.035% and Mo ≥3.0% on MTC |
| Chloride-leaning condensers | When TP316L Mo band is judged short and joints stay as-welded | Still not a duplex / superaustenitic substitute |
| Standard-C higher-Mo lists | Usually stay on TP317 rather than TP317L | C ≤0.08% acceptable when IGC strategy is not L-driven |
| Mo 2–3% sufficient | Stay on TP316L / TP316LNM | Do not over-specify 317L for ordinary 316L Mo lists |
| Mo 4–5% families | Open TP317LM / TP317LMN on the same hub | Different Mo / Ni / N rows — not nickname upgrades |
For standard-carbon higher-Mo tube open A213 TP317; for Mo 2–3% L-grade open A213 TP316L; browse the rest on the A213/A213M hub.
Weldability
TP317L tube is chosen because it welds for tube-to-tubesheet joints while keeping base-metal carbon low and molybdenum in the 3–4% band. Common practice uses ER317L under a qualified WPS so weld-metal molybdenum and carbon track the L-grade higher-Mo base tube; some fabricators accept overalloyed nickel-base filler when the corrosion review requires Mo above the deposit from matching 317L wire. Heat input control, interpass limits, and post-weld cleaning remain the fabricator’s responsibility — A213 governs the seamless tube product, not the field or shop weld procedure.
Because A213 TP317L is seamless, there is no mill longitudinal weld to radiograph the way welded pipe standards describe. Focus inspection language on tube integrity (hydro or NDE of each length), tube-to-tubesheet joint quality, and any contractual corrosion test on the base metal. If PREN requirements after welding exceed standard 317L, changing the base metal to A213 TP317LM or A213 TP317LMN is usually a better move than relying on filler selection alone. Specify end preparation and surface finish on the tube PO when orbital or clean-service joins are planned.
Surface Finishes
Standard mill delivery for ASTM A213 TP317L is solution annealed and pickled, leaving a clean matte finish suitable for most boiler and heat-exchanger tube duty. Bright annealing under protective atmosphere produces a smoother reflective surface used on some clean-process and instrumentation tube lines and must be called out because it changes the heat-treatment route. Light polish or specified Ra on the bore or OD is a commercial or service-center operation on top of A213 product, not automatic with the grade stamp.
When a hygienic or fouling-sensitive exchanger specification quotes an Ra maximum on the bore, put it on the tube purchase order with its own acceptance language and sampling plan. SHH STEEL stencils grade and heat treatment as standard requirements; polish, special OD grind, and passivation after fabrication remain commercial extras unless the contract says otherwise. End preparation (plain, slightly beveled, or as needed for tube expanding) should be ordered together with finish so receiving inspection shares one acceptance language.
Inspection and Testing
Lot testing for ASTM A213 TP317L follows tension, hardness, flattening, and flaring under A213 / A1016. Chemistry verification must include carbon ≤0.035%, molybdenum 3.0–4.0%, chromium 18.0–20.0%, and nickel 11.0–15.0%. Tensile reporting must use the Table 4 75/30 ksi pair and 35% elongation — not a copied TP316L 70/25 or TP317 34% checklist. NDE follows the ordered edition and purchaser supplements — hydrostatic testing or non-destructive electric testing of each length is the usual A213 path unless the purchase order states otherwise.
EN 10204 3.1 certificates from SHH STEEL report ladle chemistry with C and Mo, Table 4 tensile / yield / 35% elongation / hardness, and heat-treatment condition. When A262 Practice E is ordered, those results appear as specified. Dual A213/SA-213 marking and third-party witness are available when written into the enquiry. A certificate missing carbon or molybdenum is not a complete TP317L release package.
Packaging and Shipping
TP317L tubes ship in capped or plugged bundles with weather protection matched to the route. Cut lengths for boiler and exchanger bundles are labeled by heat and size; export packing uses cases or steel-frame crates when required.
Marking includes ASTM A213, grade TP317L / UNS S31703, size, heat number, and SHH STEEL identification. Dual SA-213 marking appears only when the purchase order requests it. Packing lists track the same heat numbers shown on the EN 10204 3.1 certificates so the L-grade carbon and elevated molybdenum results stay tied to the shipped lengths.
Why Choose SHH STEEL
SHH STEEL treats ASTM A213 TP317L as a low-carbon higher-molybdenum specification product: C ≤0.035%, Mo 3.0–4.0%, Cr 18–20%, Ni 11–15%, Table 4 75/30 ksi, and elongation 35% minimum are checked together before a heat is offered. Quotations state OD × wall / BWG, wall basis, finish route, A262 options, and whether dual A213/SA-213 marking is required.
We refuse nickname assemblies that stamp TP316L as 317L without clearing the 3.0% molybdenum floor and the different Cr–Ni band, or that stamp TP317 as 317L without the 0.035% carbon ceiling. EN 10204 3.1 documentation includes both C and Mo. Compare sisters on the A213/A213M hub before freezing the exchanger tube list.
Supply Capability
SHH STEEL supplies ASTM A213 TP317L seamless stainless steel tube in cold-finished and hot-finished routes across the usual boiler, superheater, and heat-exchanger OD × wall / BWG band. Capability below is an enquiry range — not a frozen warehouse SKU or tonnage claim.
| Capability | SHH STEEL practice for TP317L |
|---|---|
| Product form | Seamless cold-finished and hot-finished tube |
| Standards | ASTM A213 / A213M; dual SA-213 when PO asks |
| Size band | Typical within ~1/8 in. ID to 5 in. OD; other diameters by agreement |
| Wall basis | Minimum wall or average wall as specified |
| Documentation | EN 10204 3.1 MTC with C ≤0.035% + Mo 3–4% + 35% elong.; A262 / third-party witness on request |
| Trade terms | FOB / CFR / CIF / EXW and other agreed Incoterms |
Stock / Available sizes
SHH STEEL quotes TP317L against a stock-and-mill enquiry range rather than a frozen SKU/tonnage list. Representative OD × wall / BWG combinations for boiler and heat-exchanger tube appear below.
| Item | Typical stock / enquiry range for TP317L |
|---|---|
| Outside diameter | 19.05, 25.4, 31.8, 38.1, 42.4, 50.8, 60.3, 76.2 mm (and other boiler/HX ODs on enquiry; through the usual A213 ~5 in. [127 mm] band) |
| Wall / BWG | BWG 10–18 class walls and metric min-wall equivalents; heavier walls by agreement |
| Common OD × wall examples | 25.4 × 2.11 mm; 31.8 × 2.77 mm; 38.1 × 2.77 mm; 42.4 × 3.56 mm; 50.8 × 3.05 mm; 60.3 × 3.91 mm — illustrative, confirm min vs average wall |
| Length | Cut lengths for boiler / exchanger bundles; bends and random mill lengths on enquiry |
| Special | Non-standard OD/wall, bright anneal, dual A213/SA-213, A262 Practice E, third-party witness — confirm before heat reservation |
Send OD × wall (or BWG), wall basis, finish route, quantity or cut list, marking (A213 or dual A213/SA-213), and C / Mo / A262 notes on one enquiry. We confirm C ≤0.035%, Cr 18–20% / Ni 11–15%, Mo 3.0–4.0%, Table 4 75/30 ksi, and elongation 35% minimum without inventing fake warehouse codes. Sisters A213 TP317, A213 TP316L, and A213 TP317LM sit on the same hub.
FAQ
-
Is ASTM A213 the same as ASME SA-213 for TP317L?
- No. ASTM A213 / A213M is the ASTM International product specification for seamless boiler, superheater, and heat-exchanger tubes; ASME SA-213 / SA-213M is the separate ASME Code Book adoption. Dual-mark only when the purchase order asks for both names on the stencil and MTC. Chemistry and tensile floors align closely for a given referenced edition, but the standards remain independent documents.
-
Does ASTM A213 TP317L include welded or HCW tube?
- No. ASTM A213 covers seamless boiler, superheater, and heat-exchanger tubes only. There is no WLD or HCW manufacturing-type letter under A213. Cold-finished versus hot-finished describes the seamless process route and dimensional tolerances — not a welded product form. Order welded stainless pipe under a different product standard when that form is required.
-
What is the chemistry of ASTM A213 TP317L?
- Melting analysis for TP317L / UNS S31703 is C ≤0.035%, Mn ≤2.00%, P ≤0.045%, S ≤0.030%, Si ≤1.00%, Cr 18.0–20.0%, Ni 11.0–15.0%, and Mo 3.0–4.0%, with nitrogen as a no-requirement ellipsis. Confirm the ordered A213 edition. Unlike TP316L, the public A213 table for TP317L does not print Footnote D beside carbon — do not import a 0.040% thin-wall path unless the ordered edition says so.
-
TP317L vs TP317 — when do I need low carbon?
- Both share Mo 3–4%, Cr 18–20, and Ni 11–15. TP317 allows C ≤0.08% and uses Table 4 elongation 34%. TP317L keeps C ≤0.035% and prints elongation 35% with the same 75/30 ksi tensile/yield pair. Choose TP317L for as-welded IGC strategy with higher Mo; choose TP317 when low carbon is not mandated and the 34% elongation row is acceptable.
-
TP317L vs TP316L — why choose the higher molybdenum L-grade?
- TP316L uses Mo 2.00–3.00%, Cr 16–18, Ni 10–14, and Table 4 70/25 ksi. TP317L raises Mo to 3.0–4.0%, Cr to 18–20, Ni to 11–15, and keeps the 75/30 ksi tensile/yield pair with 35% elongation and hardness max 192 HBW / 90 HRB. Order TP317L when the datasheet names the higher Mo band with L-carbon; stay on TP316L when Mo 2–3% is sufficient.
-
Does Table 4 set a hardness limit for TP317L?
- Yes. Table 4 lists hardness maximum 192 HBW / 200 HV or 90 HRB with 75 ksi tensile, 30 ksi yield, and 35% elongation. Hardness, carbon ceiling, molybdenum floor, and Cr–Ni band all belong on the release package — none replaces the others for 317L boiler or HX tube.
-
What heat treatment does A213 require for TP317L?
- Solution treatment at a minimum of 1900 °F [1040 °C], water quench or other rapid cool. Delivery is solution annealed and pickled unless bright anneal is agreed. No mandatory ASTM grain-size number appears for TP317L in the public heat-treatment table. Put A262 Practice E on the purchase order when IGC demonstration is contractual.
-
Minimum wall vs average wall for A213 TP317L — which should I specify?
- Boiler and heat-exchanger datasheets almost always expect minimum wall. Average wall is allowed when the purchase order says so, with A1016/A1016M tolerances for that basis. State wall basis on the enquiry rather than relying on pipe schedule numbers as the primary A213 wall story.
-
Can I dual-certify TP317L with TP316L on the same heat?
- No in any practical sense: the molybdenum bands do not overlap (TP316L max 3.00% versus TP317L min 3.0% is a knife-edge that still leaves Cr–Ni mismatched — TP317L needs Cr 18–20 / Ni 11–15, not 16–18 / 10–14). Order the grade the datasheet names rather than forcing a dual from a PMI gun that only reads "high Mo" and "low C."
-
When should I step from TP317L to TP317LM or TP317LMN?
- When the datasheet names Mo 4.0–5.0% families (and the matching Ni / N / Cu rows on those grades), not when a buyer simply wants "more Mo than 316L." TP317L stops at Mo 3.0–4.0%. Open the TP317LM / TP317LMN pages on the A213/A213M hub when those chemistries are required — they are separate UNS rows, not nickname upgrades of TP317L.
-
Does Footnote D raise TP317L carbon to 0.040% on small-OD tube?
- Not in the public A213 stainless table excerpt used for this pack: TP317L prints C ≤0.035% without a Footnote D superscript, while TP316L and related LN grades carry that footnote. Do not import a 0.040% thin-wall path from a 316L checklist onto a TP317L heat unless the ordered edition explicitly applies it. Confirm the edition text on the purchase order.
-
Why does TP317L keep 75/30 ksi while TP316L drops to 70/25?
- ASTM A213 Table 4 prints 75/30 ksi for TP317L even with the L-grade carbon ceiling, matching standard TP317 and sitting above the 70/25 ksi floor used on TP304L and TP316L. Receiving checklists copied from 316L heats often expect 70/25 and incorrectly reject a heat that clears 75/30. Use the TP317L row on the ordered edition — do not import a sister L-grade’s tensile digits.
Conclusion
ASTM A213 TP317L / UNS S31703 is the low-carbon higher-molybdenum seamless stainless steel tube for boiler, superheater, and heat-exchanger service when Mo 3.0–4.0% with Cr 18–20% / Ni 11–15% and C ≤0.035% must sit above the 316L Mo band for as-welded duty. SHH STEEL supplies cold-finished and hot-finished seamless tube in the usual OD × wall / BWG band, solution annealed at 1900 °F [1040 °C], tested to Table 4 75/30 ksi, 35% elongation, and hardness limits, with carbon and molybdenum reported on EN 10204 3.1 certificates — dual SA-213 marking only when the purchase order asks.
Contact: admin@steelspecs.com