ASTM A213 TP347H Stainless Steel Tube
What is ASTM A213 TP347H Stainless Steel Tube
ASTM A213 / A213M is the ASTM International product specification for seamless ferritic and austenitic alloy-steel boiler, superheater, and heat-exchanger tubes. Grade TP347H / UNS S34709 is the high-temperature, niobium-stabilized member of the 347 family: melting carbon sits in a 0.04–0.10% band (floor and ceiling), chromium 17.0–19.0%, nickel 9.0–13.0%, and niobium is held at ≥8 × C and ≤1.10%. The heat-treatment path carries an ASTM grain-size requirement of No. 7 or coarser, with separate solution-temperature floors for cold-worked and hot-rolled routes. That package exists for creep-range boiler and superheater service where niobium stabilization and H-grade carbon share one datasheet — not as a synonym stamp for ordinary A213 TP347. Buyers who write “347H tube” still need to name A213 (or the separate ASME SA-213 adoption) on the purchase order so the mill applies H-grade chemistry, grain-size, Nb-formula, test, and marking clauses.
SHH STEEL can supply ASTM A213 TP347H stainless steel tube as seamless cold-finished and hot-finished product in the usual boiler and heat-exchanger OD × wall / BWG band, shipped with EN 10204 3.1 mill test certificates that report the full ladle chemistry (including niobium against the 8 × C formula), the Table 4 tensile and hardness results, and the grain-size result for the heat-treatment lot. When a project also needs ASME Code Book marking, we dual-mark A213 / SA-213 on the same lengths only if the purchase order says so. Browse the grade family on the A213/A213M hub.
Commercially, TP347H tube is still called 347H, S34709, or niobium-stabilized H-grade boiler tube; none of those shop names replace the ASTM grade on the MTC or stencil. Sister grades under the same ASTM standard include A213 TP347, A213 TP347HFG, A213 TP321H, A213 TP304H, and A213 TP321. A213 covers seamless tube only — no welded or HCW manufacturing type — so cold-finished versus hot-finished is the process choice, not a WLD/HCW stencil letter. Fine-grain A213 TP347HFG is a separate UNS row with its own carbon floor, grain band, and cold-finished-only rule.
Chemical Composition of A213 TP347H
Two chemistry layers matter for TP347H under ASTM A213. Melting (heat or ladle) analysis is mandatory for every heat; product analysis on finished tube applies only when Supplementary Requirement wording or the purchase order invokes it through ASTM A1016/A1016M. Product-analysis tolerances typically flow from ASTM A480/A480M Table A1.1. SHH STEEL reports actual ladle values — and product values when ordered — and does not advertise unpublished tighter catalogue windows. Two lines define the grade for a reviewer: the carbon band 0.04–0.10%, and niobium ≥8 × C with a 1.10% ceiling. That Nb multiplier is deliberately lower than the 10 × C rule on non-H A213 TP347, so do not copy a TP347 niobium check onto a TP347H heat without reopening the formula. Chromium narrows to 17.0–19.0% versus TP347’s 17.0–20.0%.
The tables below reproduce the heat analysis for TP347H / UNS S34709, the product-analysis limits from A480 Table A1.1 practice, and a short carbon / niobium snapshot against TP347, TP321H, and TP347HFG. Later A213 editions place austenitic stainless grades in Table 2 (older editions used Table 1); confirm the ordered edition on the purchase order.
Melting analysis (heat / ladle analysis)
| Element | TP347H (UNS S34709) melting analysis |
|---|---|
| Carbon (C) | 0.04 – 0.10 |
| Manganese (Mn) | ≤ 2.00 |
| Phosphorus (P) | ≤ 0.045 |
| Sulfur (S) | ≤ 0.030 |
| Silicon (Si) | ≤ 1.00 |
| Chromium (Cr) | 17.0 – 19.0 |
| Nickel (Ni) | 9.0 – 13.0 |
| Molybdenum (Mo) | … (no requirement) |
| Nitrogen (N) | … (no requirement) |
| Niobium (Nb / Cb) | ≥ 8 × C, ≤ 1.10 |
| Titanium (Ti) | … (no requirement) |
Source: ASTM A213/A213M stainless chemistry table for Grade TP347H / UNS S34709 (public mill / specification PDF excerpt — _ref_a213.txt / A213–13 table text). Confirm the ordered edition. Where ellipses appear, the ordered edition sets no requirement for that element.
Product analysis — A480/A480M Table A1.1 tolerances applied
| Element | Melting | Tolerance (A480 A1.1) | Product analysis limit |
|---|---|---|---|
| Carbon (C) | 0.04 – 0.10 | 0.01 under / over | 0.03 – 0.11 |
| Manganese (Mn) | ≤ 2.00 | 0.04 over | ≤ 2.04 |
| Phosphorus (P) | ≤ 0.045 | 0.010 over | ≤ 0.055 |
| Sulfur (S) | ≤ 0.030 | 0.005 over | ≤ 0.035 |
| Silicon (Si) | ≤ 1.00 | 0.05 over | ≤ 1.05 |
| Chromium (Cr) | 17.0 – 19.0 | 0.20 under / over | 16.80 – 19.20 |
| Nickel (Ni) | 9.0 – 13.0 | 0.15 under / 0.20 over | 8.85 – 13.20 |
| Niobium (Nb) | ≥ 8 × C, ≤ 1.10 | 0.05 over on max (Nb formula practice) | max ≤ 1.15 product; min tied to heat C |
Carbon and stabilizer snapshot — TP347 / TP347H / TP347HFG / TP321H
| Element | TP347 (S34700) | TP347H (S34709) | TP347HFG (S34710) | TP321H (S32109) |
|---|---|---|---|---|
| C | ≤ 0.08 | 0.04 – 0.10 | 0.06 – 0.10 | 0.04 – 0.10 |
| Cr | 17.0 – 20.0 | 17.0 – 19.0 | 17.0 – 19.0 | 17.0 – 19.0 |
| Ni | 9.0 – 13.0 | 9.0 – 13.0 | 9.0 – 13.0 | 9.0 – 12.0 |
| Stabilizer | Nb ≥ 10 × C, ≤ 1.10 | Nb ≥ 8 × C, ≤ 1.10 | Nb ≥ 8 × C, ≤ 1.10 | Ti ≥ 4 × (C+N), ≤ 0.70 |
Heats that also meet the non-H TP347 carbon ceiling while clearing the H-grade floor, the tighter 8 × C niobium floor, tensile, hardness, and grain-size paths can be dual-certified TP347/TP347H when the purchase order asks — do not assume it from a PMI gun. Dual TP347H/TP321H is not a chemistry path: one grade requires niobium, the other titanium. Versus A213 TP347HFG, TP347H allows a lower carbon floor (0.04% vs 0.06%), does not mandate the fine-grain 7–10 band or Footnote I softening path, and permits both cold-finished and hot-finished routes.
When product analysis is ordered, finished tube may read C 0.03–0.11%, Mn ≤2.04%, P ≤0.055%, S ≤0.035%, Si ≤1.05%, Cr 16.80–19.20%, Ni 8.85–13.20%, and Nb max ≤1.15% with the formula minimum still tied to heat carbon. Put any tighter project carbon floor or niobium floor on the purchase order before the heat is selected.
Mechanical Properties of A213 TP347H
ASTM A213 Table 4 sets the room-temperature tensile acceptance floor for TP347H at 75 ksi [515 MPa] tensile strength and 30 ksi [205 MPa] yield strength (0.2% offset), with elongation of 35% minimum in 2 in. or 50 mm — the same room-temperature pair as TP347 and TP321H. Hardness maximum is 192 HBW / 200 HV or 90 HRB, and hardness tests are part of lot acceptance under A213. What distinguishes the H grade mechanically in the product standard is the grain-size requirement: ASTM No. 7 or coarser, determined per heat-treatment lot under the ordered edition’s clause referencing ASTM E112, sitting beside the niobium stabilization chemistry.
| Property | TP347H requirement |
|---|---|
| Tensile strength, min (Table 4) | 75 ksi [515 MPa] |
| Yield strength (0.2% offset), min (Table 4) | 30 ksi [205 MPa] |
| Elongation in 2 in. or 50 mm, min (Table 4) | 35% |
| Hardness, max (Table 4) | 192 HBW / 200 HV or 90 HRB |
| Grain size | ASTM No. 7 or coarser (per heat-treatment lot) |
Source: ASTM A213/A213M Table 4 for TP347H / UNS S34709 and H-grade grain-size language (public specification PDF excerpt — _ref_a213.txt / A213–13 heat-treatment table showing grain-size column “7” for TP347H). Mechanical property requirements do not apply to tubing smaller than 1/8 in. [3.2 mm] inside diameter or thinner than 0.015 in. [0.4 mm] wall. Flattening and flaring tests are also required on a lot basis.
Room-temperature tensile equality with TP347 is why dual 347/347H stock can look attractive when carbon and Nb clear both rows; elevated-temperature allowables, the carbon floor, the coarser grain, and the H-grade heat-treatment temperatures are why the H designation exists. Note that A213 TP347HFG carries a higher Table 4 tensile floor (80 ksi [550 MPa]) plus a fine-grain band — do not treat HFG paperwork as interchangeable with TP347H. A tensile-only MTC that omits grain size or niobium is incomplete for TP347H.
Dimensions and Tolerances
Dimensional supply for ASTM A213 TP347H is tube language — outside diameter × wall thickness (minimum wall or average wall) and, commercially, BWG / gauge — not ASME B36.19 pipe schedules as the primary size story. The sizes usually furnished under A213 run from about 1/8 in. [3.2 mm] inside diameter to 5 in. [127 mm] outside diameter, with minimum wall from about 0.015 to 0.500 in. [0.4 to 12.7 mm]; other diameters may be furnished when all other requirements are met. State on the purchase order whether wall is minimum or average — boiler and superheater datasheets almost always assume a minimum-wall reading.
Outside-diameter and wall variations follow ASTM A1016/A1016M as invoked by A213. Cold-finished tubes commonly hold tighter OD control; hot-finished tubes allow wider OD and wall windows. Permissible variations from a specified average wall for cold-finished tube are often summarized as ±10% of the specified average wall. Confirm the exact A1016 rows for the OD and finish route on the ordered edition.
| Item | Typical A213 TP347H dimensional practice |
|---|---|
| Product form | Seamless only (cold-finished or hot-finished) |
| Usual size band | ~1/8 in. [3.2 mm] ID to 5 in. [127 mm] OD; wall ~0.015–0.500 in. [0.4–12.7 mm] min (or average wall if PO says so) |
| Wall basis | Minimum wall (default for boiler / superheater) or average wall when specified |
| OD / wall tolerances | Per ASTM A1016/A1016M for the finish route and size; cold-finished average wall often ±10% |
| Length | Cut lengths for boiler / superheater / HX bundles, or mill random lengths by agreement |
| Secondary size note | ASME B36.19 schedules may appear only when a buyer asks for a pipe-schedule cross-reference — not as the primary A213 size callout |
Put the cut list, design metal temperature context, and end preparation on the enquiry so mill and stock lengths can be mixed efficiently. Minimum wall is a first-class A213 concept. For cold-finished-only fine-grain product under the same family, open A213 TP347HFG.
Equivalent Grades
Equivalence language around TP347H tube is often looser than a creep-range boiler purchase order can afford. ASTM A213 Grade TP347H / UNS S34709 is the governing designation for this article; EN 1.4912 / X7CrNiNb18-10 family names and JIS SUS347H / SUS347HTB are approximate wrought names that point to similar niobium-stabilized high-temperature 18-8 families but are not automatic substitutes on an A213 mill test certificate. When a datasheet says “equivalent to 347H,” confirm which product standard, tensile/hardness table, grain-size clause, niobium formula, and heat-treatment path the mill will actually certify — and whether the buyer meant fine-grain TP347HFG instead.
| Designation | Notes |
|---|---|
| ASTM A213 / A213M Grade TP347H | Governing ASTM seamless boiler / HX tube product standard for this article |
| UNS S34709 | Unified number listed in the stainless chemistry table |
| ASME SA-213 TP347H | Separate ASME Code Book adoption — dual-mark only when the PO asks |
| EN 1.4912 family (approx.) | Approximate wrought Nb-stabilized H-grade designation; order EN tube forms under the relevant EN tube specs |
| JIS SUS347H / SUS347HTB | Approximate Japanese grade / boiler-tube names; confirm the Japanese tube product standard |
| Related plate | A240 / SA240 flat product in the same UNS family — order plate and tube under their own product standards |
Dual A213/SA-213 marking is a purchase-order option, not a claim that the two standards are one document. Compare TP347, TP347HFG, and TP321H on their own ASTM A213 pages before swapping grades on a familiar “347H” PMI reading alone.
Heat Treatment and Delivery Condition
TP347H under ASTM A213 is furnished solution treated, then quenched in water or cooled rapidly by other means. The public heat-treatment table sets separate minimum solution temperatures by finish route: cold-worked tube at 2000 °F [1100 °C], and hot-rolled tube at 1925 °F [1050 °C], with Footnote H on the hot-rolled path. Grain size after heat treatment must meet ASTM No. 7 or coarser for the heat-treatment lot. That combination — finish-route solution temperature, niobium chemistry, and coarse-grain control — is what separates TP347H paperwork from a tensile-only TP347 certificate.
Footnote H warns that a solution treating temperature above 1950 °F [1065 °C] may impair intergranular-corrosion resistance after subsequent sensitizing exposure in the indicated grades, and allows a purchaser-specified lower-temperature stabilization or resolution anneal after the higher solution anneal. Supplementary Requirement S2 lists TP347H among grades that shall be given a stabilization heat treatment at a temperature lower than the initial solution anneal when the purchaser specifies S2 — temperature as agreed between purchaser and vendor. S2 is not automatic with the grade stamp.
Cold-finished versus hot-finished is a process and dimensional route that also selects which solution-temperature floor applies; it is not a substitute for the anneal or the grain-size check. Delivery condition for SHH STEEL TP347H is solution annealed and pickled (or bright annealed by agreement), with anneal temperature, quench method, niobium result, and grain-size result stated on the EN 10204 3.1 certificate. For non-H niobium stabilization open A213 TP347; for fine-grain cold-finished HFG open A213 TP347HFG; for titanium H-grade open A213 TP321H.
Corrosion Resistance
TP347H’s chromium-rich passive film and niobium stabilization handle the oxidizing steam-side and many water-side duties typical of boiler and superheater service, with niobium tying up carbon that would otherwise form chromium carbides at grain boundaries during sensitizing thermal cycles. It is not selected primarily as a wet-chloride corrosion grade: the carbon floor that helps elevated-temperature strength still raises as-welded sensitization risk relative to low-carbon L grades when niobium is under-applied. In chloride-bearing cooling waters and many process exchangers, pitting and crevice attack become limiting, and buyers usually step to molybdenum-bearing grades rather than stretching H-grade Nb-stabilized 18-8 into wet corrosive service.
ASTM A213 itself does not publish a corrosion-rate table for TP347H; selection remains engineering judgment against fluid, temperature, velocity, and inspection philosophy inside the boiler or exchanger. When a specification calls for ASTM A262 Practice E, write Supplementary Requirement S4 onto the purchase order — and note that for niobium-bearing H grades a stabilization heat treatment under S2 may be necessary and is permitted to meet that requirement. SHH STEEL will not market TP347H as a wet-service upgrade over A213 TP304L — the H designation is about creep-range carbon, grain size, and Nb stabilization, not about better aqueous chloride resistance.
Applications of A213 TP347H Tube
TP347H seamless tube under A213 is chosen for creep-range boiler, superheater, and reheater service where the design code’s elevated-temperature allowables for S34709, the carbon floor, niobium stabilization, and the coarse-grain requirement earn their keep. It is the wrong default for as-welded wet corrosive exchangers that really need an L grade, and it is not interchangeable with fine-grain TP347HFG without checking carbon floor, tensile floor, grain band, and cold-finished-only rules. The table below pairs typical application areas with a selection note.
| Application area | Typical use of TP347H tube | Selection note |
|---|---|---|
| Boiler generating / screen tubes | Seamless A213 tube where Nb-stabilized H-grade carbon and grain size are specified | Confirm design metal temperature and code allowables for S34709 |
| Superheater / reheater | Creep-range steam tubing ordered to A213 TP347H | If fine-grain HFG is specified, open TP347HFG — do not substitute |
| High-temperature process HX | Seamless tube where elevated-temperature strength plus Nb stabilization matter | Prefer TP347 if H-grade carbon/grain size is not required |
| Dual TP347/TP347H stock | Heats that clear both chemistry (incl. Nb formulas) and grain-size / tensile rows | Ask for dual marking on the PO |
| Stabilized H-grade boiler tube | Where A213 documentation is preferred over pipe product forms | Do not substitute A312 pipe paperwork for A213 tube acceptance |
For non-H niobium open A213 TP347; for fine-grain HFG open A213 TP347HFG; for titanium H-grade open A213 TP321H; for unstabilized H-grade open A213 TP304H on the A213/A213M hub.
Weldability
TP347H tube welds with matching or near-matching niobium-bearing austenitic filler for tube-to-tubesheet joints, attachment welds, and fabrication joins. Common practice uses ER347 / ER347H (or equivalent covered electrodes) under a qualified WPS so weld-metal niobium and carbon support elevated-temperature stabilized service; many fabricators avoid defaulting to ER308L when the base tube is H-grade Nb-stabilized and the design allowables assume H-grade carbon with stabilization. Heat input control, interpass limits, and post-weld cleaning remain the fabricator’s responsibility under the applicable boiler or pressure-vessel code — A213 governs the seamless tube product, not the field or shop weld procedure.
Because A213 TP347H is seamless, there is no mill longitudinal weld to radiograph the way welded pipe standards describe. Focus inspection language on tube integrity (hydro or NDE of each length), tube-to-tubesheet joint quality, grain-size and niobium documentation on the base metal, and any contractual corrosion test. For tube that will enter wet as-welded service in a sensitizing environment without relying on niobium, many owners change the base metal to A213 TP304L. Specify end preparation and surface finish on the tube PO when orbital or clean-service joins are planned.
Surface Finishes
Standard mill delivery for ASTM A213 TP347H is solution annealed and pickled, leaving a clean matte finish suitable for most boiler and heat-exchanger tube duty. Bright annealing under protective atmosphere produces a smoother reflective surface used on some clean-process lines and must be called out because it changes the heat-treatment route — and must still deliver the required grain size and niobium chemistry. Light polish or specified Ra on the bore or OD is a commercial or service-center operation on top of A213 product, not automatic with the grade stamp.
When a fouling-sensitive exchanger specification quotes an Ra maximum on the bore, put it on the tube purchase order with its own acceptance language and sampling plan. SHH STEEL stencils grade, heat treatment, and (on request) H-grade / Nb identity as standard requirements; polish, special OD grind, and passivation after fabrication remain commercial extras unless the contract says otherwise. Order end preparation together with finish so receiving inspection shares one acceptance language.
Inspection and Testing
Base ASTM A213 testing for TP347H includes heat analysis (carbon inside 0.04–0.10%, niobium meeting ≥8 × C ≤1.10%), tension tests to the Table 4 floors (75/30 ksi), hardness tests to the Table 4 maximum (192 HBW / 90 HRB), grain-size determination (ASTM No. 7 or coarser) per heat-treatment lot, flattening and flaring tests on a lot basis, and either hydrostatic testing or nondestructive electric testing of each length. The manufacturer may choose hydro versus NDE unless the purchase order fixes the method. Marking includes the ASTM designation, grade, size, heat number, and other clause-required data.
Supplementary Requirements commonly added on TP347H tube orders are summarized below. Invoke them by number or clear purchase-order wording; mills will not assume product analysis, S2 stabilization, IGC testing, or dual TP347/TP347H marking from a verbal “full certs” note.
| Option | Purpose |
|---|---|
| Product analysis | Confirms chemistry on finished tube — useful when carbon sits near the 0.04% floor or 0.10% ceiling, or when Nb is near the 8 × C floor |
| S2 stabilizing heat treatment | Lower-temperature stabilization after the solution anneal — listed for TP347H when specified |
| S4 intergranular corrosion | A262 Practice E; S2 may be necessary for Nb-bearing H grades to meet S4 |
| Grain-size reporting | Ensures E112 result appears on the MTC for the heat-treatment lot |
| Minimum vs average wall | States which wall basis the size callout uses |
| Fixed hydro or NDE method | Removes manufacturer’s option when the end user mandates one route |
| Third-party inspection / EN 10204 3.2 | Witnessed testing and certificate when the project requires it |
Ask the mill to state lot identity clearly on the certificate so hardness, tension, niobium, and grain-size specimens map cleanly to the bundle you receive. A tensile-only MTC without grain size or Nb is incomplete for TP347H.
Packaging and Shipping
TP347H tube leaves SHH STEEL bundled, capped or end-protected, and tagged for export or domestic delivery according to the length mix and bend form on the order. Bundle tags repeat the ASTM A213 grade, OD × wall (or BWG), heat number, and PO reference so site receiving can check the shipment without opening every certificate packet first. U-bent tubes need extra cradle or case protection so bend radii and legs are not distorted in transit.
Export packing can be bare bundles, wrapped bundles, or wooden-cased lengths for bright-annealed, polished, or small-bore material. We ship under the Incoterms on the order acknowledgement — FOB, CFR, CIF, EXW, or other agreed terms. Inland trucking, bilingual destination marks, or project color coding for bundle tags should be stated on the enquiry beside the metallurgical notes.
Why Choose SHH STEEL
SHH STEEL treats ASTM A213 TP347H as a product standard with enforceable chemistry (carbon floor and ceiling, niobium formula), tensile, hardness, grain-size, finish-route heat-treatment, and marking rules — not as a catalogue nickname for “any 347H tube.” The MTC reports the full ladle chemistry including niobium against 8 × C, the Table 4 tensile/hardness set (75/30 ksi, 192 HBW / 90 HRB), and the grain-size result; the stencil carries seamless tube identity under A213; and dual A213/SA-213 marking is offered only when requested.
We keep the Nb-stabilized H-grade conversation honest for boiler and HX duty. If H-grade carbon and grain size are not required, we open A213 TP347. If fine-grain creep framing with the higher tensile floor is specified, we open A213 TP347HFG. If titanium is preferred over niobium, we open A213 TP321H. If unstabilized H-grade 18-8 is enough, we open A213 TP304H. The A213/A213M hub is organized grade by grade under ASTM, seamless tube only.
Lead times combine near-term stock lengths with mill schedules; we say which is which on the quotation. Cut-to-length, U-bending, polish, and third-party inspection are defined extras. The tube that arrives should match the ASTM callout the engineer wrote, with paperwork a third-party inspector can read without translation.
Supply Capability
SHH STEEL can supply ASTM A213 TP347H stainless steel tube against the edition and finish route named on your enquiry. The capability table below summarizes the sizes, finishes, and documents we regularly quote for this grade, followed by the Stock / Available sizes map buyers ask for when they need a quick sense of what to enquire against for Nb-stabilized H-grade boiler and superheater duty.
| Item | SHH STEEL capability for TP347H |
|---|---|
| Standard | ASTM A213 / A213M (dual SA-213 marking on request) Grade TP347H / UNS S34709 |
| Product form | Seamless only — cold-finished and hot-finished |
| Size | Typical OD × min wall (or average wall) in the A213 usual band; other diameters by agreement |
| Wall / gauge | Minimum wall or average wall; BWG / gauge callouts accepted on enquiry |
| Length | Cut-to-length for boiler / superheater / HX bundles; mill random by agreement; U-bends on enquiry |
| Finish | Annealed and pickled; bright annealed or light polish by agreement |
| Testing | Tension (75/30 ksi), hardness (max 192 HBW / 90 HRB), grain size No. 7 or coarser, Nb vs 8×C, flattening, flaring, hydro or NDE per length; full ladle chemistry on MTC; product analysis / S2 / S4 on order |
| Documents | EN 10204 3.1 with full ladle chemistry, Nb, and grain-size result; third-party inspection / 3.2 on request |
| Trade terms | FOB / CFR / CIF / EXW and other agreed Incoterms |
Stock / Available sizes
SHH STEEL quotes TP347H tube against a practical stock-and-mill enquiry range rather than a frozen warehouse SKU list. The sizes below are OD × wall / BWG combinations buyers most often request for Nb-stabilized H-grade boiler and superheater tube; availability of any single line on a given week depends on mill drawing and our inbound schedule, so treat the table as a supply map for enquiry — not a guarantee of floor tonnage.
| Item | Typical stock / enquiry range for TP347H |
|---|---|
| Outside diameter | 25.4, 31.8, 38.1, 44.5, 50.8, 63.5, 76.2, 88.9 mm (and other boiler/HX ODs on enquiry; up through the usual A213 ~5 in. [127 mm] band) |
| Wall / BWG | BWG 10–16 class walls and metric min-wall equivalents; heavier walls for high-pressure boiler duty by agreement |
| Common OD × wall examples | 31.8 × 2.77 mm; 38.1 × 3.05 mm; 50.8 × 3.05 mm; 50.8 × 3.40 mm; 63.5 × 3.40 mm; 76.2 × 3.40 mm — illustrative boiler/HX sizes, confirm min vs average wall |
| Length | Cut lengths for boiler / superheater / exchanger bundles; U-bends and straight random lengths on enquiry |
| Special | Non-standard OD/wall, bright anneal, dual TP347/TP347H marking, dual A213/SA-213 marking, S2 stabilization — confirm on enquiry before the heat is reserved |
When you send an enquiry, list OD × wall (or BWG), wall basis (minimum or average), cold-finished or hot-finished preference, quantity or cut list, required marking (A213 alone, dual A213/SA-213, and/or dual TP347/TP347H), and any Supplementary Requirements (S2, S4, product analysis). We reply with what we can ship from near-term stock versus what needs a mill run, without inventing fake warehouse codes or tonnage claims.
Send the size list, finish route, quantity or cut lengths, required marking, Supplementary Requirements, and destination on one enquiry. We will confirm chemistry (including the carbon band and Nb formula), tensile, hardness, and grain size against the stainless chemistry table, Table 4, and the H-grade grain-size rule, state what ships from near-term availability versus mill production, and keep the offer aligned with ASTM A213 / A213M. Related grades such as A213 TP347, A213 TP347HFG, and A213 TP321H sit on the same hub when the datasheet steps beyond TP347H.
FAQ
-
Is ASTM A213 the same as ASME SA-213 for TP347H?
- No. ASTM A213 / A213M is the ASTM International product specification for seamless boiler, superheater, and heat-exchanger tubes; ASME SA-213 / SA-213M is the separate ASME Code Book adoption of that grade text. Chemistry, tensile, hardness, niobium formula, and grain-size rules align closely for a given referenced edition, but they remain two independent standards. Dual-mark A213/SA-213 tube only when the purchase order asks for both names on the stencil and MTC.
-
Does ASTM A213 TP347H include welded or HCW tube?
- No. ASTM A213 covers seamless tube only. There is no WLD or HCW manufacturing type under this product standard the way ASTM A312 describes pipe. The process choice for TP347H under A213 is cold-finished versus hot-finished seamless tube, plus the H-grade heat-treatment temperatures, grain-size, niobium, and testing clauses of the ordered edition.
-
How does TP347H differ from TP347 under ASTM A213?
- TP347H holds carbon in a 0.04–0.10% range, uses niobium ≥8 × C ≤1.10% instead of the non-H 10 × C rule, narrows chromium to 17.0–19.0%, requires ASTM grain size No. 7 or coarser, and applies finish-route solution temperatures (cold-worked 2000 °F [1100 °C]; hot-rolled 1925 °F [1050 °C]). TP347 allows carbon ≤0.08% with Nb ≥10 × C and no H-grade grain-size rule. Room-temperature Table 4 tensile (75/30 ksi) and hardness match; do not treat "347H" as a synonym stamp for ordinary TP347 on the MTC.
-
What is the UNS number and chemistry of ASTM A213 TP347H?
- TP347H is UNS S34709. Melting limits include carbon 0.04–0.10%, manganese ≤2.00%, phosphorus ≤0.045%, sulfur ≤0.030%, silicon ≤1.00%, chromium 17.0–19.0%, nickel 9.0–13.0%, and niobium ≥8 × C ≤1.10%, with molybdenum, nitrogen, and titanium as no-requirement ellipses. Product-analysis limits apply only when ordered, typically from A480 Table A1.1 via A1016. Confirm the ordered A213 edition for the exact stainless-table number.
-
Does A213 Table 4 set a hardness limit for TP347H?
- Yes. Table 4 for TP347H lists tensile strength, yield strength, elongation, and a hardness maximum of 192 HBW / 200 HV or 90 HRB. Hardness tests are part of lot acceptance under A213, which differs from many A312 pipe rows for the same UNS number that omit a Table 4 hardness cap. Grain size (No. 7 or coarser) sits beside those Table 4 numbers as an H-grade acceptance item.
-
Why does ASTM A213 control grain size on TP347H?
- Coarse grain (ASTM No. 7 or coarser) after the finish-route solution treatment supports the elevated-temperature creep-rupture behavior that the H designation is written for, sitting beside niobium stabilization. A tensile-only MTC without an E112 grain-size result is incomplete for TP347H. Ask the mill to report grain size per heat-treatment lot on the EN 10204 3.1 certificate before releasing the heat to fabrication.
-
What heat treatment does ASTM A213 require for TP347H?
- TP347H is solution treated at a minimum of 2000 °F [1100 °C] for cold-worked tube or 1925 °F [1050 °C] for hot-rolled tube, then water quenched or rapidly cooled, with grain size No. 7 or coarser for the heat-treatment lot. Footnote H and Supplementary Requirement S2 address high solution temperature / stabilization when ordered. Ask the mill to state anneal temperature, quench method, niobium, and grain-size result on the EN 10204 3.1 certificate.
-
What is Supplementary Requirement S2 for TP347H?
- S2 requires a stabilization heat treatment at a temperature lower than the initial solution anneal, with the temperature agreed between purchaser and vendor. The public A213–13 excerpt lists TP347H among grades that shall receive S2 when specified. For niobium-bearing H grades, S2 may also be necessary and is permitted to meet Supplementary Requirement S4 (A262 Practice E). S2 is never automatic with the grade stamp alone.
-
TP347H vs TP347HFG — which should I order?
- Order TP347H when the datasheet wants H-grade Nb stabilization with grain size No. 7 or coarser, carbon 0.04–0.10%, and either cold-finished or hot-finished tube. Order TP347HFG when the datasheet specifically names fine-grain HFG: carbon 0.06–0.10%, grain size ASTM No. 7 to 10, Table 4 tensile 80 ksi [550 MPa], cold-finished only, and the Footnote I softening-plus-2150 °F solution path. Do not substitute one for the other on a familiar "347H" reading.
-
TP347H vs TP321H — niobium or titanium for H-grade tube?
- Both are H-grade stabilized austenitics with carbon 0.04–0.10% and grain size No. 7 or coarser. TP347H uses niobium ≥8 × C ≤1.10% with Ni 9–13%; TP321H uses titanium ≥4 × (C + N) ≤0.70% with Ni 9–12%. Filler metal, high-temperature allowables, and end-user preference often decide; do not swap them on a familiar "stabilized H" PMI reading without checking the datasheet’s stabilizer and UNS number.
-
Minimum wall vs average wall — which should I order for A213 TP347H?
- Order minimum wall when the boiler or superheater datasheet is written around a guaranteed minimum thickness after tolerance — the usual practice for A213 H-grade tube. Order average wall only when the purchase order explicitly allows average-wall product and the designer has accepted that basis. Put the wall basis on the enquiry before the mill selects A1016 tolerance tables.
-
Is TP347H a good choice for wet corrosive heat-exchanger service?
- Usually no as a first choice for chloride-rich aqueous duty. The carbon floor that helps elevated-temperature strength and the absence of molybdenum mean pitting and crevice attack can limit life; niobium helps IGC when properly applied but does not replace Mo for chlorides. Prefer TP304L or TP316L for wet as-welded service; reserve TP347H for creep-range boiler and superheater framing where Nb-stabilized H-grade rules earn their keep.
Conclusion
ASTM A213 TP347H / UNS S34709 is the niobium-stabilized, carbon-controlled, coarse-grain seamless stainless steel tube grade for creep-range boiler, superheater, and heat-exchanger service when elevated-temperature allowables, a 0.04–0.10% carbon band, niobium ≥8 × C ≤1.10%, finish-route solution temperatures, and ASTM grain size No. 7 or coarser share one datasheet. SHH STEEL supplies cold-finished and hot-finished seamless tube in the usual OD × wall / BWG band, solution annealed, tested to Table 4 tensile and hardness limits with niobium and grain size reported, and documented on EN 10204 3.1 certificates — with dual SA-213 marking only when the order asks for that separate ASME standard. For sister grades and stock-oriented size discussions, start from the A213/A213M hub, then send your OD × wall list, wall basis, dual-marking needs, and Nb / grain-size / S2 requirements so we can align mill and near-term availability to the ASTM callout.
Contact: admin@steelspecs.com