ASME SA213 TP317 Stainless Steel Tube | ASME SA213 Stainless Steel - SHH STEEL

ASME SA213 TP317 Stainless Steel Tube

ASME SA213 TP317 / UNS S31700 higher-molybdenum seamless boiler, superheater and heat-exchanger tube — C ≤0.08%, Cr 18.0–20.0%, Ni 11.0–15.0%, Mo 3.0–4.0%, Table 4 75/30 ksi with elongation 34% min, hardness max 192 HBW / 90 HRB, 1900 °F solution anneal. SHH STEEL supplies cold-finished and hot-finished seamless tube with EN 10204 3.1 MTCs.
Grade
TP317 / UNS S31700
Standard
ASME SA213 / SA213M
Product form
Seamless boiler / superheater / heat-exchanger tube (cold-finished and hot-finished)
Size
Typical OD × min wall (or average wall) within ~1/8 in. [3.2 mm] ID to 5 in. [127 mm] OD and ~0.015–0.500 in. [0.4–12.7 mm] wall; other diameters by agreement
Share:
Overview
Chemical Composition
Mechanical Properties
Specification
Equivalent Grades
Heat Treatment
Corrosion Resistance
Applications
Weldability
Surface Finishes
Inspection and Testing
Packaging and Shipping
Why Choose SHH STEEL
Supply Capability
FAQ
Conclusion

What is ASME SA213 TP317 Stainless Steel Tube

ASME SA-213 / SA-213M is the ASME Boiler and Pressure Vessel Code Book adoption of the seamless ferritic and austenitic alloy-steel boiler, superheater, and heat-exchanger tube product text. When a registered vessel, Code-stamped exchanger, or owner specification invokes that adoption by name, SA-213 is the governing product standard — an independent Code Book line, not a merged title with ASTM A213. Use SA213/SA213M as the series entry point for the stainless tube spine.

Grade TP317 / UNS S31700 is the higher-molybdenum austenitic row that sits a full percentage point of Mo above the 316 family inside that SA-213 stainless text. Melting carbon is capped at 0.08%, chromium rises to 18.0–20.0%, nickel to 11.0–15.0%, and molybdenum sits in a mandatory 3.0–4.0% band. Table 4 sets tensile at 75 ksi [515 MPa] / 30 ksi [205 MPa] with elongation 34% minimum — one point below the 35% printed for most sister austenitics — and hardness max 192 HBW / 90 HRB. Buyers who write “317 HX tube” on a bill of materials still need to name SA-213 on the purchase order so the mill applies the tube product standard, minimum-wall rules, and the elevated Mo floor together.

SHH STEEL can supply ASME SA213 TP317 as seamless cold-finished and hot-finished tube in the usual OD × wall / BWG band, with EN 10204 3.1 certificates that report molybdenum inside 3.0–4.0% together with the 75/30 ksi tensile set, 34% elongation, and hardness. Dual SA-213/A213 marking is added only when the purchase order asks; the live twin is A213 TP317.

Shop names include “317,” “S31700,” and “higher-Mo 317 tube.” Helpful for routing; the purchase order should still carry ASME SA-213 Grade TP317 / UNS S31700, wall basis, OD × wall or BWG, finish route, and any Supplementary Requirements. Sister SA213 pages include SA213 TP316, SA213 TP317L, SA213 TP317LM, and SA213 TP317LMN when Mo 4–5% or N-bearing higher-Mo paths are required. Seamless only — no Manufacturing Types (SML / WLD / HCW) H2.

Chemical Composition of SA213 TP317

Two chemistry layers matter for TP317 under ASME SA-213. Melting (heat or ladle) analysis is mandatory for every heat; product analysis on finished tube applies only when Supplementary Requirement wording or the purchase order invokes it through the general requirements (commonly ASTM A1016/A1016M). Product-analysis tolerances typically flow from ASTM A480/A480M Table A1.1. Reviewers should verify Mo 3.0–4.0%, Cr 18.0–20.0%, and Ni 11.0–15.0% together — a heat that clears TP316 Mo 2–3% fails this row, and Mo bands do not dual-stamp between 316 and 317 families.

UNCERTAIN: exact SA-213 / A213 edition year; stainless chemistry table number; A480 Mo 3–4 / Ni 11–15 product-tolerance digits (0.10 under/over on Mo and 0.15 under/over on Ni from sister practice applied here); nitrogen analysis method when N is reported by agreement (no mandatory N requirement on this row) — confirm on the ordered edition.

Melting analysis

Element TP317 (UNS S31700) melting analysis
Carbon (C) ≤ 0.08
Manganese (Mn) ≤ 2.00
Phosphorus (P) ≤ 0.045
Sulfur (S) ≤ 0.030
Silicon (Si) ≤ 1.00
Chromium (Cr) 18.0 – 20.0
Nickel (Ni) 11.0 – 15.0
Molybdenum (Mo) 3.0 – 4.0
Nitrogen (N) … (no requirement; analysis method by agreement when reported)

That melt table is the acceptance chemistry for every heat of SA213 TP317. Molybdenum must clear 3.0% and must not exceed 4.0%; chromium and nickel sit above the 316-family windows to support that Mo level. Nitrogen has no mandatory requirement on this row — do not invent an N max from mill catalogues.

Product analysis (when required)

Element Melting Tolerance (A480 A1.1) Product analysis limit
Carbon (C) ≤ 0.08 0.01 over ≤ 0.09
Manganese (Mn) ≤ 2.00 0.04 over ≤ 2.04
Phosphorus (P) ≤ 0.045 0.010 over ≤ 0.055
Sulfur (S) ≤ 0.030 0.005 over ≤ 0.035
Silicon (Si) ≤ 1.00 0.05 over ≤ 1.05
Chromium (Cr) 18.0 – 20.0 0.20 under / over 17.80 – 20.20
Nickel (Ni) 11.0 – 15.0 0.15 under / over 10.85 – 15.15
Molybdenum (Mo) 3.0 – 4.0 0.10 under / over 2.90 – 4.10

When product analysis is invoked, A480 tolerances apply as shown. Molybdenum’s product window uses the 0.10-under / 0.10-over practice associated with Mo 3–4 bands, and nickel uses 0.15 under/over — both treated as UNCERTAIN digit confirmation on the ordered A480 path. A product Mo result of 2.85% fails even when melt looked acceptable.

Snapshot vs sister grades

Element TP316 (S31600) TP317 (S31700) TP317L (S31703)
C ≤ 0.08 ≤ 0.08 ≤ 0.035
Cr 16.0 – 18.0 18.0 – 20.0 18.0 – 20.0
Ni 10.0 – 14.0 11.0 – 15.0 11.0 – 15.0
Mo 2.00 – 3.00 3.0 – 4.0 3.0 – 4.0
Table 4 elong. min 35% 34% 35%

Against SA213 TP316, Mo rises a full point and Cr/Ni windows move up; Mo bands do not dual. Against SA213 TP317L, carbon stays at the standard 0.08% max while elongation sits one point lower at 34%. Against Mo 4–5% sisters, see SA213 TP317LM / SA213 TP317LMN.

Mechanical Properties of SA213 TP317

ASME SA-213 sets the tensile acceptance floor for TP317 at 75 ksi [515 MPa] tensile strength and 30 ksi [205 MPa] yield strength (0.2% offset), with elongation of 34% minimum in 2 in. or 50 mm and hardness capped at 192 HBW / 200 HV or 90 HRB. That 34% elongation digit is intentional — do not silently upgrade it to 35% from sister austenitic habit. Tensile and yield match the ordinary 316-family floor; grade distinction sits in Mo 3–4% and the Cr/Ni windows, not in a higher strength number.

Property TP317 requirement (Table 4)
Tensile strength, min 75 ksi [515 MPa]
Yield strength (0.2% offset), min 30 ksi [205 MPa]
Elongation in 2 in. or 50 mm, min 34%
Hardness, max 192 HBW / 200 HV or 90 HRB
Grain size No mandatory ASTM grain-size number in the public heat-treatment table for TP317

Public heat-treatment excerpts used for this pack do not print a mandatory ASTM grain-size number for TP317 the way H-grades do. Do not invent a No. 7 clause on the MTC unless the ordered edition or purchase order requires one. Hardness and tensile review still use the 192 HBW / 75/30 ksi caps with the 34% elongation floor.

Flattening, flaring, and reverse-bend tests follow SA-213 / general-requirements practice. Hydrostatic testing or NDE is selected per specification and PO. Dual-marked jobs still clear SA-213 mechanical text — see A213 TP317.

Dimensions and Tolerances

Dimensional supply for ASME SA213 TP317 is tube language — outside diameter × wall thickness (minimum wall or average wall) and, commercially, BWG / gauge — not ASME B36.19 pipe schedules as the primary size story. Usual SA-213 sizes run from about 1/8 in. [3.2 mm] inside diameter to 5 in. [127 mm] outside diameter, with minimum wall from about 0.015 to 0.500 in. [0.4 to 12.7 mm]; other diameters may be furnished when all other requirements are met.

Heat-exchanger and process datasheets that pick higher-Mo tube usually assume minimum wall — state wall basis on the purchase order. Outside-diameter and wall variations follow the general requirements invoked by SA-213 (commonly ASTM A1016/A1016M). Cold-finished tubes commonly hold tighter OD; hot-finished tubes allow wider windows.

Item Typical SA213 TP317 dimensional practice
Product form Seamless only (cold-finished or hot-finished)
Usual size band ~1/8 in. [3.2 mm] ID to 5 in. [127 mm] OD; wall ~0.015–0.500 in. [0.4–12.7 mm]
Wall basis Minimum wall (common for HX datasheets) or average wall if PO says so
OD / wall tolerance Per general requirements (commonly A1016/A1016M) for the ordered finish
Length Straight random / cut-to-length; U-bend by agreement

BWG / gauge callouts are accepted on enquiry; certificates should still show OD and wall in inch or millimetre units. U-bends and polished ID finishes are commercial options on top of SA-213 dimensional rules — they do not replace Mo 3–4% chemistry or the 34% elongation floor.

Equivalent Grades

Equivalence talk around TP317 must keep the Mo 3–4% band and the elevated Cr/Ni windows intact. ASME SA-213 Grade TP317 / UNS S31700 is the governing designation for this article; “317 or 316” on a drawing is not automatic interchange when the datasheet actually needs Mo above the 316 ceiling.

Designation Notes
ASME SA-213 / SA-213M Grade TP317 Governing ASME Code Book seamless boiler / HX tube product standard for this article
UNS S31700 Unified number in the stainless chemistry table
ASTM A213 TP317 Separate ASTM product specification — dual-mark only when the PO asks
Related Mo 2–3% SA213 TP316 — Mo 2–3%, Cr 16–18 / Ni 10–14; not dual with Mo 3–4
Related L-grade SA213 TP317L — same Mo 3–4%, C ≤0.035, elong. 35%
Related Mo 4–5% SA213 TP317LM / SA213 TP317LMN — separate Mo / Ni / N rows
Related plate A240 / SA240 flat product in the 317 family — order plate and tube under their own standards

If a datasheet says “317 or equivalent,” confirm Mo 3.0–4.0, Cr 18–20, Ni 11–15, and SA-213 naming. Plate under A240 / SA240 does not automatically qualify as SA-213 tube. Non-Code ASTM purchase: A213 TP317.

Heat Treatment and Delivery Condition

TP317 under ASME SA-213 is furnished solution treated at a minimum of 1900 °F [1040 °C], then quenched in water or cooled rapidly by other means. That heat-treatment row applies to both cold-finished and hot-finished seamless tube. Public excerpts used here do not attach a mandatory ASTM grain-size number to TP317; do not invent one on the certificate unless the ordered edition or PO requires it.

Cold-finished versus hot-finished is a process and dimensional route, not a substitute for the solution anneal. Skipping or under-cooling the solution treatment can leave a structure that sensitizes in service even when ladle molybdenum looked acceptable on paper. Delivery condition for SHH STEEL TP317 is solution annealed and pickled (or bright annealed by agreement), with anneal temperature, quench method, and molybdenum on the EN 10204 3.1 certificate.

Unlike H grades such as SA213 TP316H, TP317 has no carbon floor and no grain-size mandate. If a project datasheet asks for ASTM A262 Practice E, put that Supplementary Requirement on the purchase order rather than assuming base SA-213 includes it. For as-welded IGC-critical lists, many owners move to SA213 TP317L instead of relying on standard-carbon 317 alone.

Corrosion Resistance

TP317’s defining corrosion claim versus the 316 family is the higher molybdenum band: 3.0–4.0% Mo improves resistance to pitting and crevice attack in many chloride-leaning aqueous services relative to Mo 2–3% grades, while the 18–20 / 11–15 Cr–Ni balance supports the austenitic structure around that Mo level. It is still not a duplex or super-austenitic alloy, and it is still not an L-grade: carbon up to 0.08% means as-welded intergranular corrosion risk after tube-to-tubesheet welding needs separate review.

SA-213 itself does not publish a corrosion-rate table for TP317; selection remains engineering judgment against fluid, temperature, velocity, and inspection philosophy. When a specification calls for ASTM A262 Practice E, write that Supplementary Requirement onto the purchase order so the test is contractual.

SHH STEEL will not claim TP317 equals SA213 TP317LM / SA213 TP317LMN (Mo 4–5% families) or superaustenitics in severe brine — those are separate grade rows with their own chemistries. For as-welded IGC-critical higher-Mo duty, prefer SA213 TP317L.

Applications of SA213 TP317 Tube

TP317 is ordered for Code and near-Code heat-exchanger, condenser, and process-tube circuits that specify higher-molybdenum austenitic seamless tube — often where chloride-leaning aqueous duty sits above ordinary 316 PREN and the datasheet names 317 / S31700 rather than 316. Boiler / superheater use appears when the datasheet names the grade; H-grade creep duty with carbon floor and grain-size mandates usually points elsewhere.

Enquiry patterns ask for seamless cold-finished HX OD × minimum-wall tube, sometimes with ID polish or U-bends for bundle replacement. Hot-finished seamless remains available when size favors it. MTC review should always show Mo inside 3.0–4.0% together with the 75/30 ksi tensile set and 34% elongation.

Sister steering: Mo 2–3% → SA213 TP316; L-carbon higher Mo → SA213 TP317L; Mo 4–5% → SA213 TP317LM / SA213 TP317LMN.

Weldability

TP317 tube welds with matching or near-matching higher-Mo austenitic filler selected for the project WPS (fabricators often call ER317 / ER317L or project-approved Mo grades above ordinary 316 fillers). Elevated molybdenum in the base metal improves localized-corrosion resistance; it does not remove sensitization risk in the HAZ when carbon sits up to 0.08% and heat input is poorly controlled.

Tube-to-tubesheet procedures should name TP317 / S31700. Do not assume a TP316 WPS covers Mo 3–4% without review, and do not treat TP317 as an automatic L-grade substitute on as-welded IGC-critical lists — many stewards simply order TP317L when low carbon is the dominant need.

Dual SA-213/A213 marking does not change filler selection. If A262 Practice E after fabrication or on mill product is required, state that Supplementary Requirement on the purchase order so the test is contractual rather than assumed.

Surface Finishes

Standard mill delivery for ASME SA213 TP317 is solution annealed and pickled, leaving a clean matte finish suitable for heat-exchanger and process-tube duty. Bright annealing is available by agreement when OD appearance or polish steps favor it.

ID/OD polish and U-bend conditioning are commercial additions — they do not replace Mo 3–4% chemistry or the 34% elongation floor. End caps and dry export packaging matter more than paint on pickled stainless.

SHH STEEL notes the ordered surface route on the packing list and aligns it with the MTC finish description for receiving inspection.

Inspection and Testing

Base ASME SA-213 testing for TP317 includes heat analysis (Mo 3.0–4.0%, Cr 18.0–20.0%, Ni 11.0–15.0%), tension tests to the 75/30 ksi floors with 34% elongation, hardness to 192 HBW / 90 HRB, and flattening / flaring tests for the ordered size. Hydrostatic testing or NDE follows the path selected on the purchase order.

Certificate reviewers should confirm molybdenum inside 3.0–4.0% and chromium/nickel in the elevated windows rather than trusting a “316 family” PMI Mo peak that sits below 3.0%. Product analysis, when ordered, applies A480 tolerances including the Mo/Ni windows noted as UNCERTAIN digit confirmation above.

Supplementary Requirements, A262 practices by agreement, and third-party witness are available on request. EN 10204 3.1 is default; 3.2 when required. Dual SA-213/A213 names appear only when dual marking was ordered.

Packaging and Shipping

TP317 tube leaves SHH STEEL bundled, capped or end-protected, and tagged for export or domestic delivery according to length mix and bend form. Bundle tags repeat ASME SA-213 Grade TP317, UNS S31700, heat number, size, and wall basis so receivers can match the 3.1 certificate — including Mo — without opening every bundle.

Export packing uses seaworthy bundling appropriate for pickled stainless. Marking follows SA-213 and any dual-mark text the PO adds, referencing A213 TP317 only when dual ASTM marking was ordered.

Why Choose SHH STEEL

SHH STEEL treats ASME SA213 TP317 as a Code Book higher-Mo product with enforceable Mo 3–4%, Cr 18–20%, Ni 11–15%, 75/30 ksi tensile, 34% elongation, hardness, and marking rules — not as “316 with a little more molybdenum” checked only by a Mo PMI peak below 3.0%. Enquiry review verifies the Mo band before release.

That stops silent substitution with TP316 heats on datasheets that actually require S31700. We keep SA-213 and A213 independent, dual-mark only on request, and put Mo on the 3.1 certificate so inspectors can verify the elevated floor.

Cross-links: SA213 TP316, SA213 TP317L, SA213 TP317LM, SA213 TP317LMN, hub SA213/SA213M.

Supply Capability

SHH STEEL can supply ASME SA213 TP317 stainless steel tube against the edition and finish route named on your enquiry. The capability table below summarizes sizes, finishes, and documents we regularly quote, followed by the Stock / Available sizes map for higher-Mo heat-exchanger and process tube.

Item SHH STEEL capability for TP317
Standard ASME SA213 / SA213M (dual A213 marking on request)
Grade TP317 / UNS S31700
Product form Seamless only — cold-finished and hot-finished
Size Typical OD × min wall (or average wall) in the SA-213 usual band; other diameters by agreement
Wall / gauge Minimum wall or average wall; BWG / gauge callouts accepted on enquiry
Length Cut-to-length for HX / process bundles; U-bend by agreement
Documentation EN 10204 3.1 MTC with Mo 3–4%; A262 / witness on request
Trade terms FOB / CFR / CIF / EXW and other agreed Incoterms

Stock / Available sizes

SHH STEEL quotes TP317 against a stock-and-mill enquiry range rather than a frozen SKU or tonnage list. Representative OD × wall / BWG combinations below are an enquiry map for higher-Mo heat-exchanger tube — confirm live availability and cut lengths on the RFQ.

OD (in.) Typical wall / BWG enquiry band Notes
1/2 – 1 BWG 16–12 / ~0.065–0.109 in. Small HX / instrument sizes
1-1/4 – 2 BWG 14–10 / ~0.083–0.134 in. Common process exchanger band
2-1/2 – 3 0.120 – 0.250 in. min wall Heavier HX wall
3-1/2 – 5 0.180 – 0.300 in. min wall Upper usual SA-213 OD by agreement

Send OD × wall (or BWG), wall basis, quantity, finish route, any A262 Practice E requirement, and whether dual A213 marking is required. SHH STEEL returns capability against ASME SA213 TP317 / UNS S31700 — not a TP316 substitute.

FAQ

Is ASME SA-213 the same as ASTM A213 for TP317?
No. ASME SA-213 / SA-213M is the ASME Code Book adoption; ASTM A213 / A213M is the separate ASTM product specification. Chemistry — including Mo 3.0–4.0%, Cr 18–20%, Ni 11–15% — tensile 75/30 ksi, elongation 34%, and hardness floors align closely for a given referenced edition, but they remain independent standards. Dual-mark only when the purchase order asks for both names on the stencil and MTC.
Does ASME SA213 TP317 include welded or HCW tube?
No. This SA213 product page covers seamless boiler, superheater, and heat-exchanger tube only. SA-213 for the austenitic grades discussed here is a seamless tube product form; welded (WLD) and hot-finished continuous-welded (HCW) manufacturing-type labels from pipe standards are not used as product-form options on this pack. If your datasheet actually needs welded stainless pipe, order it under the matching pipe specification.
What is the UNS number and chemistry focus of ASME SA213 TP317?
UNS S31700. Check C ≤0.08%, Cr 18.0–20.0%, Ni 11.0–15.0%, and Mo 3.0–4.0% together. Nitrogen has no mandatory requirement on this row. Product analysis, when ordered, applies A480 A1.1 tolerances. Mo bands do not dual with TP316.
TP317 vs TP316 — why choose the higher molybdenum grade under SA213?
TP317 raises Mo from 2.00–3.00% to 3.0–4.0% and moves Cr/Ni to 18–20 / 11–15. That step improves pitting and crevice resistance in many chloride-leaning aqueous services relative to 316-family Mo. Tensile stays 75/30 ksi, but elongation is 34% min rather than 35%. Order TP317 when the datasheet needs Mo above the 316 ceiling.
TP317 vs TP317L — when do I need low carbon?
Order TP317L when as-welded intergranular resistance needs C ≤0.035% together with the same Mo 3–4% band (elongation then sits at 35%). Order TP317 when the project accepts C ≤0.08% and the datasheet names standard-carbon 317. Same Mo identity; different carbon paths and elongation digits.
Why is elongation 34% on SA213 TP317 instead of 35%?
Table 4 prints 34% minimum elongation for TP317 — one point below most sister austenitics including TP317L. Do not silently upgrade the certificate to 35% from habit. Tensile and yield remain 75/30 ksi; hardness max remains 192 HBW / 90 HRB.
Does SA-213 set a hardness limit for TP317?
Yes. Table 4 caps hardness at 192 HBW / 200 HV or 90 HRB, with 75 ksi tensile, 30 ksi yield, and 34% elongation. Grade distinction is chemical (Mo 3–4% and elevated Cr/Ni), not a higher tensile floor.
What heat treatment does ASME SA-213 require for TP317?
Solution treatment at a minimum of 1900 °F [1040 °C] with water quench or other rapid cool. Public excerpts used here do not mandate an ASTM grain-size number for TP317. Name A262 Practice E on the PO when demonstration testing is contractual.
Minimum wall vs average wall — which should I order for SA213 TP317?
Most heat-exchanger datasheets assume minimum wall; average wall only when the PO says so. Usual SA-213 sizes run about 1/8 in. ID to 5 in. OD with min wall about 0.015–0.500 in.; other diameters by agreement. Prefer OD × wall / BWG language over B36.19 pipe schedules.
Is TP317 a good choice for as-welded IGC-critical tube-to-tubesheet joints?
Often not by itself. Carbon up to 0.08% leaves sensitization risk after welding that L-grades address with C ≤0.035%. Many owners move to SA213 TP317L when low carbon and Mo 3–4% must travel together, or specify A262 Practice E on the PO when quench quality must be demonstrated on TP317 product.
Can you dual-certify ASME SA-213 and ASTM A213 TP317?
Yes, when the purchase order asks for dual marking and the heat meets both named editions — including Mo 3–4%, Cr 18–20%, Ni 11–15%, 75/30 ksi, and 34% elongation. Dual marking is stencil and documentation practice, not proof the names are synonyms. Otherwise SA-213 stands alone for Code Book jobs.
When should I step from TP317 to TP317LM or TP317LMN under SA213?
Step up when the datasheet needs Mo 4.0–5.0% (and the matching Ni / N rows on those grades) rather than Mo 3–4%. TP317LM and TP317LMN are separate chemistry rows — not dual stamps of TP317. Compare their SA213 pages before substituting inside a boiler or exchanger list.

Conclusion

ASME SA213 TP317 / UNS S31700 is the higher-molybdenum seamless stainless steel tube grade for Code boiler, superheater, and heat-exchanger service when Mo 3.0–4.0%, Cr 18.0–20.0%, Ni 11.0–15.0%, a 75/30 ksi tensile floor with 34% elongation, hardness max 192 HBW / 90 HRB, and a 1900 °F solution anneal are required together. SHH STEEL supplies cold-finished and hot-finished seamless tube in the usual OD × wall / BWG band with EN 10204 3.1 MTCs that report Mo. Compare sister grades on the same Code Book spine, or start from SA213/SA213M. Enquire with OD × wall, wall basis, quantity, and document needs at admin@steelspecs.com.