ASTM A312 UNS S31655 Stainless Steel Pipe
What is ASTM A312 UNS S31655 Stainless Steel Pipe
ASTM A312/A312M is the ASTM product specification for seamless, welded and heavily cold-worked austenitic stainless steel pipe intended for high-temperature and general corrosive service. It is a standard in its own right, maintained by ASTM, and this page is written against A312/A312M for UNS S31655, with every number taken from the A312 tables. ASME publishes a separate Code standard, SA-312, which is a different document even where its text runs parallel, so the two titles should not be treated as synonyms on a purchase order.
Within A312, UNS S31655 is a lean-nickel, nitrogen-strengthened grade listed by UNS number only, with no TP designation. Table 1 sets C ≤0.030%, Mn ≤2.00%, Cr 19.5–21.5%, Ni 8.0–9.5%, Mo 0.50–1.50%, N 0.14–0.25% and Cu ≤1.00%. Table 4 requires 92 ksi [635 MPa] tensile and 45 ksi [310 MPa] yield, with elongation of 35% longitudinal / 25% transverse, and Table 2 calls for a solution anneal at 1900 °F [1040 °C] minimum followed by rapid cooling. S31655 is not individually listed in Table 2, so the default solution-anneal temperature applies.
S31655 is a strength-driven grade rather than a high-alloy corrosion grade. Its Table 1 row combines low carbon (≤0.030%), relatively high chromium at 19.5–21.5%, a lean nickel window of 8.0–9.5% and a modest 0.50–1.50% molybdenum, then relies on 0.14–0.25% nitrogen to hold the austenite and raise strength. Copper up to 1.00% is permitted.
The result is a Table 4 row of 92 ksi [635 MPa] tensile and 45 ksi [310 MPa] yield, a clear step above the 316L and 316N rows. For pressure piping, a higher allowable stress can translate into a thinner wall, which is the main reason engineers name S31655. It should not be mistaken for a molybdenum-rich chloride grade; with at most 1.50% Mo, its pitting resistance sits nearer the ordinary 300-series grades than the 4–6% Mo alloys.
SHH STEEL can supply ASTM A312 UNS S31655 stainless steel pipe as seamless (SML), welded (WLD) or heavily cold-worked (HCW) product, in ASME B36.19 schedules or special OD and wall combinations, with EN 10204 3.1 mill test certificates showing the full Table 1 analysis, the Table 4 results and the anneal actually applied. Third-party 3.2 inspection is arranged when the enquiry names the agency. If a project also needs ASME SA-312 marking for Code piping, we arrange dual marking only when the purchase order asks for it; the separate ASME-framed page for this grade is SA312 UNS S31655.
In the market this chemistry may appear as no widely used trade name or EN equivalent is given; the grade is ordered by its UNS number. Those labels are useful in conversation but carry no acceptance value; the pipe is UNS S31655 only when the heat certificate matches Table 1 line by line. Buyers comparing options within the ASTM series usually look next at A312 TP316L, A312 TP316N, A312 TP316LN, A312 TP304LN and A312 UNS S31726, and the full grade list sits on the A312/A312M hub. None of those pages describes a drop-in substitute, because chemistry, strength and anneal differ in ways that matter to the design.
Manufacturing Types (SML / WLD / HCW)
A312 recognizes three manufacturing routes for UNS S31655 pipe, and choosing between them is a purchase-order decision based on the design code, the size and wall, and how the owner wants the pipe inspected. The route never relaxes the chemistry: whichever way the pipe is made, the heat must still meet Table 1 and every length must still be solution annealed at 1900 °F [1040 °C] minimum before release.
- Seamless (SML) — made without welding at any stage. It is usually preferred for heavy walls, high-pressure lines and owners who exclude welded pipe from a design class, and it is the common route for small-bore UNS S31655 lines.
- Welded (WLD) — made from strip or plate by an automatic process without filler metal in the longitudinal seam, then heat treated. The strip or plate heat must itself carry the full UNS S31655 chemistry, so the certificate should trace the coil or plate heat number.
- Heavily cold-worked (HCW) — welded pipe cold worked by at least 35% reduction of wall and weld before the final anneal, with the weld radiographed before cold working. Order it only when the project specifically calls for the HCW marking and its process controls.
Every finished length is either hydrostatically tested or tested by a nondestructive electric method, and the mill may choose unless the purchase order fixes one. Mechanical test lots follow the sampling clauses of the referenced A312 edition. Naming SML, WLD or HCW on the enquiry lets the mill line up material, heat treatment and test plans before the heat is allocated, which is especially important for a UNS-only grade like UNS S31655 that is rarely held as general stock.
Chemical Composition of ASTM A312 UNS S31655
Two layers of chemistry apply to ASTM A312 UNS S31655. The melting (heat) analysis in Table 1 is mandatory on every heat and is the figure the mill reports on the certificate. Product analysis on finished pipe is optional; when Supplementary Requirement S1 is ordered, the A480/A480M Annex A1.1 tolerances define how far a check analysis may deviate from the Table 1 limits.
The first table shows the Table 1 melting limits. Read single values as maximums and ranges as both a floor and a ceiling, and expect every element in the table to appear on the MTC as a measured value rather than a summary line.
| Element | UNS S31655 melting analysis |
|---|---|
| Carbon (C) | ≤ 0.030 |
| Manganese (Mn) | ≤ 2.00 |
| Phosphorus (P) | ≤ 0.045 |
| Sulfur (S) | ≤ 0.015 |
| Silicon (Si) | ≤ 1.00 |
| Chromium (Cr) | 19.5 – 21.5 |
| Nickel (Ni) | 8.0 – 9.5 |
| Molybdenum (Mo) | 0.50 – 1.50 |
| Nitrogen (N) | 0.14 – 0.25 |
| Copper (Cu) | ≤ 1.00 |
For UNS S31655 the elements given as ranges deserve the closest look, because they define the grade rather than merely limit impurities. A heat that drifts outside any of those ranges is not UNS S31655, however close the rest of the analysis looks, and checking each range element against the certificate is the first job of receiving inspection.
When product analysis is ordered, the second table pairs each Table 1 limit with its A480 tolerance and the resulting acceptance limit on finished pipe. It lets an inspector judge a check-analysis result without reworking the tolerance rules by hand.
| Element | Melting (Table 1) | Tolerance (A480 A1.1) | Product analysis limit |
|---|---|---|---|
| Carbon (C) | ≤ 0.030 | 0.005 over | ≤ 0.035 |
| Manganese (Mn) | ≤ 2.00 | 0.04 over | ≤ 2.04 |
| Phosphorus (P) | ≤ 0.045 | 0.010 over | ≤ 0.055 |
| Sulfur (S) | ≤ 0.015 | 0.005 over | ≤ 0.020 |
| Silicon (Si) | ≤ 1.00 | 0.05 over | ≤ 1.05 |
| Chromium (Cr) | 19.5 – 21.5 | 0.20 under / 0.25 over | 19.30 – 21.75 |
| Nickel (Ni) | 8.0 – 9.5 | 0.10 under / over | 7.90 – 9.60 |
| Molybdenum (Mo) | 0.50 – 1.50 | 0.03 under / 0.05 over | 0.47 – 1.55 |
| Nitrogen (N) | 0.14 – 0.25 | 0.01 under / 0.02 over | 0.13 – 0.27 |
| Copper (Cu) | ≤ 1.00 | 0.05 over | ≤ 1.05 |
Any row marked as a gap or by agreement in that table is a place where A480 does not tabulate a tolerance for the level this grade requires, and the acceptance band then has to be agreed in writing on the order. Product tolerances never apply to the heat analysis itself, which must stay inside Table 1.
Mechanical Properties of ASTM A312 UNS S31655
Table 4 sets the room-temperature tensile requirements that every lot of UNS S31655 pipe must meet after the final anneal. For this grade the minimums are 92 ksi [635 MPa] tensile and 45 ksi [310 MPa] yield, with elongation of 35% longitudinal / 25% transverse. The table below summarizes the row as it applies to this grade.
| Property | S31655 |
|---|---|
| Tensile, min | 92 ksi [635 MPa] |
| Yield, min | 45 ksi [310 MPa] |
| Elongation | 35% L / 25% T |
These are minimum values for acceptance, not design allowables. Allowable stresses for pressure design come from the governing piping code at the design temperature, and the code tables, not the A312 minimum, decide wall thickness. A312 does not assert a Table 4 hardness maximum for this grade, so if a hardness limit is needed for a specific service, write it on the purchase order.
At receiving, check that the tensile report quotes the right row for UNS S31655 rather than a generic 300-series line, that elongation is recorded with its direction, and that the specimen type matches the pipe size. Flattening tests and, where applicable, bend tests on welded pipe follow the A312 rules for the manufacturing type.
Dimensions, Tolerances and Stock Sizes
Dimensional supply for ASTM A312 UNS S31655 follows ASME B36.19 for standard NPS and schedule combinations, with special OD and wall by agreement when a project needs a section the schedules do not cover. Outside-diameter variations follow ASTM A999/A999M, and wall-thickness variations follow A312 Table 3, summarized below.
| NPS designator | Wall over | Wall under |
|---|---|---|
| 1/8 to 2-1/2 incl., all t/D | 20.0% | 12.5% |
| 3 to 18 incl., t/D up to 5% | 22.5% | 12.5% |
| 3 to 18 incl., t/D over 5% | 15.0% | 12.5% |
| 20 and larger, welded, all t/D | 17.5% | 12.5% |
| 20 and larger, seamless, t/D up to 5% | 22.5% | 12.5% |
| 20 and larger, seamless, t/D over 5% | 15.0% | 12.5% |
Read the table by NPS band first, then by the wall-to-diameter ratio. The under-tolerance is 12.5% throughout, while the permitted over-tolerance varies with size and route. Whether the ordered wall is nominal or minimum (Supplementary S8) changes how those percentages are applied, so state it on the purchase order.
- Lengths — single random, double random or cut-to-length as ordered
- Ends — plain or bevelled; give bevel angle and root face when the WPS is already fixed
- Jointers — not permitted unless the purchase order allows them
Stock / Available sizes. SHH STEEL quotes UNS S31655 against a practical stock-and-mill enquiry range rather than a frozen warehouse list. Because this is a UNS-only alloy, much of the volume is mill-order, and selected common sizes may be available from stock or remnant programmes. The table below shows the representative sizes we most often discuss; availability by route and wall must be confirmed on each enquiry, and we do not publish SKU numbers or tonnages.
| Representative size | Typical schedules / notes |
|---|---|
| NPS 1/2 – 2 | Sch 10S / 40S / 80S; confirm the wall saving with the designer |
| NPS 3 – 8 | Sch 10S / 40S / 80S |
| NPS 10 – 24 | Sch 10S / 40S; route and wall confirmed on enquiry |
| Special OD × wall | By agreement; state OD, wall (nominal or minimum) and length practice |
Typical examples we quote include 21.3 mm × 2.77 mm (NPS 1/2 Sch 40S), 60.3 mm × 3.91 mm (NPS 2 Sch 40S), 114.3 mm × 3.05 mm (NPS 4 Sch 10S) and 168.3 mm × 7.11 mm (NPS 6 Sch 40S). Special OD × wall, non-standard lengths and mixed SML/WLD packages are routine on enquiry; send the size list and we will separate what can ship from stock from what needs a mill slot.
Equivalent Grades
Equivalence for UNS S31655 is mainly an identity question. Under ASTM A312 the governing designation is the UNS number itself, and any trade name, European number or plate designation is only an engineering map back to the Table 1 row. The table below lists the references buyers most often bring to us, with how each relates to the A312 grade.
| Designation | How it relates to ASTM A312 UNS S31655 |
|---|---|
| ASTM A312 / A312M UNS S31655 | Governing pipe standard for this page; UNS identity only, no TP name |
| ASME SA-312 UNS S31655 | Separate ASME Code standard; dual marking only when the purchase order names both |
ASME SA-312 is listed because Code projects often need it, but it is a separate standard; when both marks are needed, the purchase order should name both and the mill certifies the heat against each. If a project specification quotes a brand name or EN number, ask for certification to ASTM A312 UNS S31655 and list any extra requirements separately rather than assuming the reference covers them.
Heat Treatment and Delivery Condition
All A312 pipe is furnished in the heat-treated condition. For UNS S31655 the solution anneal is 1900 °F [1040 °C] minimum, followed by quenching in water or rapid cooling by other means. S31655 is not individually listed in Table 2, so the default solution-anneal temperature applies. The purpose is to put alloying elements back into solution and leave a clean, uniform austenitic structure before the pipe is tested and shipped.
UNS S31655 is not an H grade under A312, so the Table 5 grain-size requirement, clause 6.2 reheat rules and mandatory heat-treatment lot marking do not apply unless the owner specification adds them. The MTC should state the actual temperature and cooling method used, because a mill running mixed grades through one furnace may otherwise default to a neighbouring grade’s practice. If pipe is hot formed or heavily cold bent during fabrication, plan a full re-anneal to the same Table 2 practice where the governing code requires it, and confirm that the furnace can hold the temperature for the size before the work starts.
Corrosion Resistance
General corrosion resistance of S31655 is broadly in the range buyers expect from standard austenitic grades, helped by its relatively high chromium and nitrogen. Low carbon keeps sensitization risk down during welding, so ordinary fabrication does not normally need a post-weld anneal for intergranular reasons.
It is not, however, an answer to severe chloride pitting or crevice problems; for those duties the 4–5% Mo grades such as S31726 or the 6Mo superaustenitics are the usual comparison. A312 gives no corrosion data for S31655, so service suitability should be confirmed by the owner’s materials engineer before the grade is frozen on the datasheet.
Applications of ASTM A312 UNS S31655 Pipe
The application table below explains where the high Table 4 row of S31655 pays for itself, and where it does not. They are starting points for selection, not approvals, and the owner’s materials engineer should confirm each against process data.
| Application | Why UNS S31655 | Buyer note |
|---|---|---|
| Pressure piping where a high yield floor saves wall | 92/45 ksi Table 4 row | Use code allowables for S31655 |
| General corrosive service needing more strength than 316N | High Cr and N, lean Ni | Not a high-Mo chloride grade |
| Projects naming S31655 on the datasheet | UNS-only identity | Stencil and MTC must show UNS S31655 |
In every case the order should name ASTM A312 UNS S31655, the manufacturing route, size and wall, and the certificate requirements. Where a project also buys sister grades, keep them segregated through fabrication, because the Table 4 and Table 2 rows differ even when the pipes look identical on the rack.
Weldability
UNS S31655 pipe can be joined by GTAW, GMAW and SMAW when the procedure is qualified on the actual grade. On filler metal, Table 6 shows an ellipsis for S31655, so there is no standard filler mapping and the consumable must be agreed. Mill longitudinal welds on WLD and HCW pipe are autogenous, so the filler question applies only to fabrication welds made in the shop or on site.
Because Table 6 gives no filler, the consumable has to be agreed and qualified on S31655 base metal, with attention to dilution of the lean nickel and high nitrogen. A filler that undermatches the 92 ksi base metal may fail the procedure tensile test, so check strength as well as chemistry when choosing it. Back-purge roots with argon, keep interpass temperature controlled, and remove heat tint by pickling or mechanical cleaning where the owner specification requires a clean surface.
Surface Finishes
Surface condition for ASTM A312 UNS S31655 pipe should be stated on the purchase order rather than left to the mill default. For stainless pipe, residual scale, embedded free iron and handling contamination can matter as much as the nominal finish name, particularly on corrosion-critical lines.
- Annealed and pickled — the usual delivery condition after solution treatment
- Blasted and pickled — when scale removal needs a mechanical assist before passivation
- Bright annealed — by agreement for selected sizes and routes
- Polished OD or ID — grit or Ra target by agreement; state which surface
Export orders should also state how ends are protected and that chloride-bearing labels or markers must not contact the bore. Those handling notes prevent avoidable rejections at receiving without changing the A312 metallurgical release.
Inspection and Testing
The base acceptance package for ASTM A312 UNS S31655 combines heat chemistry, tension testing against the Table 4 row, flattening or bend tests per the route, heat-treatment evidence and a hydrostatic or electric test on every length. Supplementary requirements are optional until they are written on the order; the table below lists the ones buyers request most often for this grade.
| Option | Purpose |
|---|---|
| S1 product analysis | Confirms chemistry on finished pipe using A480 tolerances |
| S5 radiography | Weld integrity on WLD pipe |
| S7 intergranular corrosion | A262 Practice E check where the owner requires it |
| S8 minimum wall | Wall interpreted as minimum rather than nominal |
| Project corrosion test | For example ASTM G48, with method and acceptance agreed on the order |
EN 10204 3.1 certification is our standard document set, and 3.2 third-party inspection is arranged when the enquiry names the agency and hold points. Hydrostatic versus electric testing should also be fixed on the purchase order if the project has a preference, because a silent mill option is not the same as an approved method.
Packaging and Shipping
Each length of UNS S31655 pipe is marked with ASTM A312, UNS S31655, manufacturing route, size, heat number and test method, with SA-312 added only when dual marking is ordered. Packing lists repeat the heat numbers so receiving can match pipe to certificates without opening every bundle.
- End caps or bevel protectors as ordered
- Bundles strapped with protected contact points to limit iron pick-up
- Wooden cases or waterproof wrapping for ocean freight when specified
- Packing list with heat numbers, sizes and certificate references
Tell us the destination and any handling limits early, so packing suits the transport route and the receiving site instead of being redone at the port, and so special marking such as project tag numbers can be applied at the mill.
Why Choose SHH STEEL
SHH STEEL supplies specification-driven stainless pipe and plate, and for ASTM A312 UNS S31655 we quote against the edition you name rather than a generic catalogue sheet. UNS-only grades are where generic sourcing goes wrong most often: a heat that looks close on paper can miss one Table 1 element, carry the wrong tensile row or skip the specified anneal. Our job is to catch those issues before the pipe is made, not after it arrives.
- Full Table 1 chemistry for UNS S31655 on the MTC, including every range element
- The correct Table 4 row (92/45 ksi) and the 1900 °F [1040 °C] minimum anneal stated on the certificate
- Honest filler guidance based on what Table 6 does and does not say
- SML, WLD and HCW routes with EN 10204 3.1 MTCs, and 3.2 inspection on request
- Dual A312 / SA-312 marking only when the purchase order asks for both
If you are still choosing between UNS S31655 and its sister grades, send the service conditions, design temperature and preferred route; we will tell you plainly when a different A312 grade would fit better or cost less, rather than pushing whatever happens to be closest in name.
Supply Capability
SHH STEEL can supply ASTM A312 UNS S31655 pipe against the edition and route named on your enquiry. The capability table below summarizes the sizes, finishes and documents we regularly quote for this grade, and each line can be tightened on the purchase order.
| Item | SHH STEEL capability for UNS S31655 |
|---|---|
| Standard | ASTM A312 / A312M UNS S31655 |
| Manufacturing types | SML, WLD, HCW |
| Size | NPS 1/8 and up per ASME B36.19; special OD and wall by agreement |
| Schedules | 5S, 10S, 40S, 80S and non-standard walls |
| Length | Single random, double random or cut-to-length |
| Finish | Annealed and pickled; blasted and pickled; bright annealed or polished by agreement |
| Heat treatment | 1900 °F [1040 °C] minimum, rapid cool |
| Tensile | 92/45 ksi |
| Documents | EN 10204 3.1 with full Table 1 analysis; 3.2 on request |
| Trade terms | FOB, CFR, CIF, EXW and other agreed Incoterms |
Stock / Available sizes. The representative stock-and-mill range for UNS S31655 is shown in the Dimensions section (NPS 1/2–24 in typical Sch 10S/40S/80S combinations). Selected common sizes may ship from stock or remnant programmes, while heavy-wall seamless, unusual schedules and large quantities are normally mill-order; ask for a live check against your size list rather than relying on a catalogue claim.
A useful enquiry states the A312 edition, UNS S31655, route, NPS or OD × wall (nominal or minimum), quantity and length, finish, and any product analysis, corrosion test or 3.2 requirement. With that information we can confirm route, lead time and document package on the first reply instead of trading questions.
FAQ
-
Is ASTM A312 the same as ASME SA-312 for UNS S31655?
- No. They are two independent standards: ASTM A312/A312M is the ASTM product specification, and ASME SA-312 is a separate Code standard used in Code piping. The UNS S31655 requirements usually run parallel, but if your project needs both, name both on the purchase order and ask for dual marking on a heat certified to each.
-
What chemistry defines ASTM A312 UNS S31655?
- Table 1 sets C ≤0.030%, Mn ≤2.00%, Cr 19.5–21.5%, Ni 8.0–9.5%, Mo 0.50–1.50%, N 0.14–0.25% and Cu ≤1.00%. Every element with a range must be inside it on the heat analysis, and the MTC should report all of them as measured values. If S1 product analysis is ordered, A480 tolerances apply to the finished pipe only, never to the heat analysis.
-
UNS S31655 vs TP316N: which is stronger under ASTM A312?
- S31655 has the higher Table 4 row at 92/45 ksi, well above A312 TP316N. TP316N carries 2–3% Mo and more nickel, while S31655 has 0.50–1.50% Mo, 8.0–9.5% Ni and more Cr and N. Choose TP316N for 316-class corrosion behaviour and S31655 when wall saving is the main goal.
-
What are the tensile requirements for ASTM A312 UNS S31655?
- Table 4 requires 92 ksi [635 MPa] tensile and 45 ksi [310 MPa] yield, with elongation of 35% longitudinal / 25% transverse. These are acceptance minimums after the final anneal, not design allowables. Pressure design uses the governing code's allowable stress at temperature, which is why the code, not this table, sets the wall.
-
Seamless or welded UNS S31655 pipe: which should I order?
- Seamless is usually chosen for small bores, heavy walls and owners who exclude welded pipe. Welded pipe, made without filler and then annealed, is often more economical in larger diameters and thin walls. Both must meet the same Table 1 chemistry and heat treatment; the design code and inspection plan decide.
-
Is UNS S31655 a high-molybdenum chloride grade?
- No. Molybdenum is only 0.50–1.50%, so its chloride pitting resistance is far below the 4–5% Mo grades and the 6Mo superaustenitics. S31655 is selected for strength with ordinary austenitic corrosion behaviour. For seawater or acidic chloride duty, compare S31726 or S31254 instead and check the owner's corrosion data.
-
Does S31655 need a special anneal under ASTM A312?
- No special listing applies. S31655 is not individually named in Table 2, so the default solution anneal at 1900 °F [1040 °C] minimum followed by rapid cooling applies. It is not an H grade, so there is no Table 5 grain-size rule. The MTC should still state the actual temperature and cooling method.
-
What filler metal should be used to weld UNS S31655 pipe?
- Table 6 shows an ellipsis for S31655, so there is no standard filler mapping and the consumable must be agreed. Whatever consumable is chosen, qualify it on UNS S31655 base metal, record the class on the WPS and PQR, and keep heat input and interpass temperature under control. The mill seam on WLD pipe is autogenous, so this applies only to fabrication welds.
-
Which sizes of ASTM A312 UNS S31655 pipe can SHH STEEL supply?
- We quote NPS 1/8 upward to ASME B36.19 schedules such as 10S, 40S and 80S, plus special OD and wall by agreement. Representative enquiry sizes run from NPS 1/2 to 24; selected sizes may come from stock, and the rest are mill-order, confirmed size by size on each enquiry.
-
How should I check an MTC for ASTM A312 UNS S31655 pipe?
- Confirm the certificate names ASTM A312/A312M and UNS S31655, reports every Table 1 element as a measured heat value, quotes the Table 4 row for this grade (92/45 ksi), and states the anneal temperature and cooling method. Then match heat numbers on the certificate to the pipe stencil and packing list.
-
Is intergranular corrosion testing required for UNS S31655 pipe?
- Not by default. Supplementary Requirement S7 (A262 Practice E) applies only when the purchase order invokes it, and the base A312 release for UNS S31655 does not include it. If the owner specification calls for it, write S7 on the order so the mill can plan sampling and the sensitizing treatment.
Conclusion
ASTM A312 UNS S31655 is a lean-nickel, nitrogen-strengthened grade with C ≤0.030%, Mn ≤2.00%, Cr 19.5–21.5%, Ni 8.0–9.5%, Mo 0.50–1.50%, N 0.14–0.25% and Cu ≤1.00%, a Table 4 floor of 92/45 ksi and a solution anneal at 1900 °F [1040 °C] minimum. It is ordered by UNS number, and it is not a drop-in replacement for A312 TP316N or any other sister grade. Put the A312 edition, route, size and wall, finish and any supplementary tests on the purchase order, then check the EN 10204 3.1 certificate against Table 1 and Table 4 before release. SHH STEEL can supply ASTM A312 UNS S31655 pipe to the edition you name; browse sister grades on the A312/A312M hub, or send your size list to admin@steelspecs.com.