ASTM A312 TP201 Stainless Steel Pipe
What is ASTM A312 TP201 Stainless Steel Pipe
ASTM A312/A312M covers seamless, welded, and heavily cold-worked austenitic stainless steel pipe intended for high-temperature and general corrosive service. Grade TP201 is listed in Table 1 as UNS S20100. Commercially the same product may be called A312 TP201 pipe, ASTM A312 Grade TP201, or 201 stainless steel pipe when the purchase order clearly references ASTM A312/A312M. For pressure piping and project documentation, cite the full grade designation and the edition of ASTM A312 on the purchase order and on the mill test certificate—do not rely on a bare “201” market label.
TP201 is an austenitic chromium–manganese–nickel–nitrogen grade. Versus classic 18-8 chromium–nickel grades, it raises manganese and allows controlled nitrogen while keeping nickel leaner (3.5–5.5% on heat analysis). Chromium remains in the 16.0–18.0% band. That chemistry still supports the tensile and elongation floors in ASTM A312 Table 4 for many general corrosive and utility services, at a more economical nickel bill of material than TP304-class pipe when the fluid and temperature suit 201-class stainless.
SHH STEEL can supply ASTM A312 TP201 stainless steel pipe to the edition named on your enquiry, in seamless (SML), welded (WLD), and heavily cold-worked (HCW) form. We quote ASME B36.19 schedules and special OD and wall by agreement, ship with EN 10204 3.1 mill test certificates that report the full Table 1 chemistry, and can dual-mark ASTM A312 / ASME SA-312 when the purchase order asks for Code Book piping and the heat and tests meet both independent editions. Please confirm NPS, wall or schedule, finish, length practice, and any supplementary tests when you enquire.
Common commercial names and how they map to the ordered product are listed below. Always put both the TP name and the UNS number on the order, because “201” stock is easily mixed with higher-strength or low-carbon sisters in the market.
- ASTM A312 TP201 / UNS S20100 — preferred marking language for ASTM product and dual-marked pipe when A312 is the governing purchase standard
- ASME SA-312 TP201 — a separate ASME Boiler and Pressure Vessel Code Book standard with matching grade tables; order it only when the Code stamp or owner specification requires SA-312 (see optional cross-link below)
- UNS S20100 — unified numbering system identity used on MTCs and in cross-reference tables
- 201 stainless steel pipe — market shorthand; confirm ASTM A312/A312M and heat-analysis limits on the order
Related flat product in the same UNS family is available as plate. When a project mixes plate and pipe, buyers often pair this pipe grade with SA240 so that heat chemistry language stays consistent across forms. Pipe itself must still be ordered and tested to ASTM A312/A312M—not to the plate specification. Within the ASTM A312 series, compare A312 TP201LN (UNS S20153), A312 TP304, A312 TP304L, A312 TP316, and A312 TP316L before locking the grade. For Code Book dual marking on the same chemistry, the sister ASME page is SA312 TP201—treat it as a separate standard, not a synonym title. Grade hub: A312/A312M
Manufacturing Types (SML / WLD / HCW)
ASTM A312/A312M defines three manufacturing routes that may be marked on finished TP201 pipe. Selecting the route is a purchase-order decision driven by design code, size range, wall thickness, and inspection preference. It does not change the Table 1 chemistry of Grade TP201.
- Seamless (SML) — no welding at any stage of manufacture. Seamless is preferred when the project specification excludes welded pipe, when thick walls favor seamless production, or when the piping class documentation is written around seamless product only.
- Welded (WLD) — automatic welding without filler metal. The weld is finished so that the pipe meets dimensional and mechanical requirements after the final heat treatment required by ASTM A312. Welded product is widely used for common NPS and schedule combinations where the specification accepts welded austenitic pipe.
- Heavily cold-worked (HCW) — welded pipe that is cold worked to a reduction of area of wall and weld of at least 35% before the final anneal, again without filler metal in the longitudinal weld. HCW is ordered when the buyer wants the HCW marking and the process controls written into ASTM A312 for that route.
Each finished length is hydrostatically tested or nondestructively electrically tested. The manufacturer may choose the method unless the purchase order fixes one. Marking on the pipe typically includes the manufacturer, grade, heat number, NPS or outside diameter and schedule or wall thickness, and the manufacturing type letters SML, WLD, or HCW. When comparing seamless versus welded TP201 offers, check manufacturing type and the hydro or NDE method on the mill test certificate—not only the grade stamp.
Chemical Composition of ASTM A312 TP201
Two chemistry layers matter: melting (heat / ladle) analysis—mandatory per heat under ASTM A312/A312M Table 1—and product analysis when ordered (Suppl. S1 / PO). ASTM A312/A312M defer product-analysis tolerances through ASTM A999/A999M §6.3 to ASTM A480/A480M-22a Table A1.1. SHH STEEL reports actual ladle and, when ordered, product values—never unpublished tighter windows.
Melting analysis (heat / ladle analysis) — Table 1
Heat analysis for Grade TP201 / UNS S20100 from ASTM A312/A312M Table 1 is summarized below. Values are maximum unless a range is shown. Read the table together with the product-analysis row that follows when finished-pipe chemistry is part of acceptance.
| Element | TP201 (UNS S20100) melting analysis |
|---|---|
| Carbon (C) | ≤ 0.15 |
| Manganese (Mn) | 5.5 – 7.5 |
| Phosphorus (P) | ≤ 0.060 |
| Sulfur (S) | ≤ 0.030 |
| Silicon (Si) | ≤ 1.00 |
| Chromium (Cr) | 16.0 – 18.0 |
| Nickel (Ni) | 3.5 – 5.5 |
| Nitrogen (N) | ≤ 0.25 |
Source: ASTM A312/A312M Table 1 for Grade TP201. Do not treat secondary catalog sheets as a substitute for the ordered edition.
Mn and N distinguish 201 from classic TP304; Ni is leaner. Carbon ≤0.15% is above an “L” grade ceiling—review welding and post-weld exposure when sensitization risk matters. Versus A312 TP201LN, TP201 allows higher carbon and sulfur and has no copper maximum or nitrogen minimum in Table 1, so the two grades must not be interchanged even when a PMI gun reads a similar chromium–nickel balance.
Product analysis — A480/A480M Table A1.1 tolerances applied to Table 1
When product analysis is ordered, finished-pipe chemistry shall meet Table 1 as modified by the product-analysis tolerances of ASTM A480/A480M Table A1.1 (via A999 §6.3 deferral). The verified product-analysis limits for TP201 are:
| Element | Melting (Table 1) | Tolerance (A480 A1.1) | Product analysis limit |
|---|---|---|---|
| Carbon (C) | ≤ 0.15 | 0.01 over | ≤ 0.16 |
| Manganese (Mn) | 5.5 – 7.5 | 0.05 under / 0.06 over | 5.45 – 7.56 |
| Phosphorus (P) | ≤ 0.060 | 0.010 over | ≤ 0.070 |
| Sulfur (S) | ≤ 0.030 | 0.005 over | ≤ 0.035 |
| Silicon (Si) | ≤ 1.00 | 0.05 over | ≤ 1.05 |
| Chromium (Cr) | 16.0 – 18.0 | 0.20 under / over | 15.80 – 18.20 |
| Nickel (Ni) | 3.5 – 5.5 | 0.07 under / 0.10 over | 3.43 – 5.60 |
| Nitrogen (N) | ≤ 0.25 | 0.02 over | ≤ 0.27 |
If an enquiry only says “201 stainless pipe,” confirm Table 1 limits, manufacturing type, and product analysis before rolling. These product limits are acceptance windows for finished pipe, not melt targets, and they should appear on the certificate when S1 or equivalent purchase-order language is invoked.
Mechanical Properties of ASTM A312 TP201
Tensile requirements for TP201 are given in ASTM A312/A312M Table 4. Specimens and orientation follow the testing clauses of the standard and the referenced general requirements (A999/A999M as applicable). The minima below are the mandatory acceptance floor for the lot.
| Property | TP201 requirement (Table 4) |
|---|---|
| Tensile strength, min | 75 ksi [515 MPa] |
| Yield strength (0.2% offset), min | 38 ksi [260 MPa] |
| Elongation in 2 in. or 50 mm (or 4D) | 35% longitudinal / 25% transverse, min |
Actual mill test certificate values are often higher than these floors; design calculations should still use Table 4 unless the purchase order states higher guaranteed values that the mill has accepted in writing. Versus A312 TP304, TP201 shares the 75 ksi tensile minimum but carries a higher 38 ksi yield minimum (TP304: 30 ksi). A312 TP201LN sits well above both at 95/45 ksi and must not be assumed interchangeable on strength alone.
Hardness: ASTM A312 Table 4 does not list a hardness maximum for TP201. Hardness is not a separately mandated Table 4 acceptance item. Do not treat catalog Brinell or Rockwell figures as specification-mandatory. If hardness matters for fabrication or end-user acceptance, state the limit on the purchase order and verify it on the MTC; otherwise omit hardness as a mandatory acceptance item. For chloride service prefer A312 TP316 or A312 TP316L. Flattening/bend and tension run on a lot basis; supplementary tests only when listed on the PO.
Dimensions and Tolerances
Dimensional practice for austenitic stainless steel pipe ordered to ASTM A312 typically follows ASME B36.19 / B36.19M stainless-steel pipe schedules. Outside diameter and wall thickness are stated as NPS and schedule, or as OD and specified wall. Common schedules for TP201 enquiry include Schedule 5S, 10S, 40S, and 80S. Other walls and non-standard OD/wall combinations are available by agreement when both the mill and the order accept them.
Outside-diameter variations follow ASTM A999/A999M, and wall-thickness variations follow ASTM A312 Table 3 as summarized below. State on the purchase order whether wall is nominal or minimum (Supplementary S8), because the two readings produce different pipe from the same size line.
| NPS designator | Wall over | Wall under |
|---|---|---|
| 1/8 to 2-1/2 incl., all t/D | 20.0% | 12.5% |
| 3 to 18 incl., t/D up to 5% | 22.5% | 12.5% |
| 3 to 18 incl., t/D over 5% | 15.0% | 12.5% |
| 20 and larger, welded, all t/D | 17.5% | 12.5% |
| 20 and larger, seamless, t/D up to 5% | 22.5% | 12.5% |
| 20 and larger, seamless, t/D over 5% | 15.0% | 12.5% |
Source: ASTM A312 Table 3; outside diameter variations per A999/A999M.
- NPS / DN: commonly from NPS 1/8 upward; large NPS and heavy walls depend on manufacturing type (SML versus WLD/HCW) and mill capability—confirm on enquiry
- Schedules: 5S, 10S, 40S, 80S and special walls by agreement
- Length: single random (SRL), double random (DRL), or fixed cut lengths as stated on the purchase order
- Ends: plain end (PE), beveled end (BE), or other end preparations by agreement
SHH STEEL quotes the applicable tolerance clause rather than dumping entire A999 tables. Confirm max wall and NPS near the edge of B36.19 practice before acceptance. On thin schedules with threaded or socket-weld ends, check that the remaining wall is still adequate after the 12.5% under-tolerance. Jointers are not permitted unless the purchase order allows them.
Stock / Available sizes
SHH STEEL quotes ASTM A312 TP201 against a practical supply range rather than a fixed warehouse SKU list. The representative sizes below are the combinations we most often enquiry and mill for this grade; availability moves with rolling cycles, so treat the table as a stock enquiry guide—not a guarantee that every line is sitting on the floor today.
| Item | Typical supply / stock enquiry range |
|---|---|
| NPS range | NPS 1/2 – 24 (smaller and larger by agreement; confirm mill route) |
| Common schedules | Sch 10S, 40S, 80S (also 5S where mill tooling allows) |
| Example OD × wall | 21.3 × 2.77 mm; 33.4 × 3.38 mm; 60.3 × 3.91 mm; 88.9 × 5.49 mm; 114.3 × 6.02 mm (B36.19 Sch 40S examples) |
| Special sizes | Non-standard OD/wall, cut-to-length, and heavy walls on enquiry |
| Manufacturing types | SML / WLD / HCW as ordered |
When you enquire, state ASTM A312/A312M Grade TP201 (UNS S20100), NPS or OD × wall, schedule or whether wall is nominal/minimum, manufacturing type, length practice, and finish. We will confirm what can ship from near-term mill slots versus what needs a dedicated rolling, without inventing tonnage claims that the certificate cannot support.
Equivalent Grades
Equivalence for TP201 must be stated carefully. Chemistry approximations across regional designations help material selection discussions; they are not automatic one-to-one substitutes for ASTM A312 pipe without an approved material specification and design-code acceptance.
| Designation | Notes |
|---|---|
| ASTM A312 / A312M Grade TP201 | Governing pipe product standard for this article |
| UNS S20100 | Unified number listed in Table 1 |
| ASME SA-312 Grade TP201 | Separate Code Book standard with matching grade tables when dual marking or ASME stamping is required — see SA312 TP201 |
| EN 1.4372 (X12CrMnNiN17-7-5) | Approximate wrought stainless designation; EN tube/pipe product forms are ordered under the relevant EN product specs, not by EN number alone on an A312 MTC |
| JIS SUS201 | Approximate Japanese grade name; confirm the Japanese pipe/tube product standard when ordering JIS product |
| Plate counterpart | SA240 for flat product in the same UNS family |
Within ASTM A312, A312 TP201LN (UNS S20153) has its own Table 1/Table 4 limits—do not interchange with TP201. Sisters: A312 TP304, A312 TP304L, A312 TP316, A312 TP316L, and A312 UNS S20400. Hub: A312/A312M
Pressure-code caution: EN/JIS approximations do not authorize B31 or Section VIII substitution without engineered approval. ASTM A312 and ASME SA-312 remain two independent standards even when chemistry tables align for a given edition.
Heat Treatment and Delivery Condition
All pipe furnished to ASTM A312 shall be heat treated. For TP201 and other grades that do not carry an individual temperature row in Table 2, the default minimum solution-annealing temperature is 1900 °F [1040 °C], followed by water quenching or another rapid cool sufficient to prevent harmful carbide reprecipitation. That Table 2 default is SHH STEEL’s delivery baseline unless the ordered edition of ASTM A312 states otherwise for the heat.
Seamless pipe may be quenched after hot forming when the edition allows and finishing temperature is not below the min anneal. H-grade reheating notes do not change this TP201 path. HCW cold reduction is done before final anneal; delivery remains the annealed condition—cold work is not a final hardness condition.
Commercial delivery condition typically includes:
- Solution annealed to ASTM A312 Table 2 requirements for TP201
- Pickled and descaled, or bright annealed, as ordered (see Surface Finishes)
- Straightened and cut to the ordered length practice
- Hydrotested or NDE-tested per length as required by the standard and the purchase order
Ask the mill to state the anneal temperature and quench method on the EN 10204 3.1 certificate so receiving inspection can clear the heat against Table 2 without chasing verbal confirmations after the pipe has arrived.
Corrosion Resistance
TP201 is selected for general corrosive service where lean-nickel austenitic stainless with manganese–nitrogen austenite stabilization is accepted by the end-user specification. In many oxidizing aqueous environments and atmospheric exposures, 201-class stainless can perform adequately for utility and light process duty. It is not a universal substitute for classic 18-8 or molybdenum-bearing grades.
Versus TP304: Similar Cr band, leaner Ni with Mn–N stabilization. Not automatically interchangeable with A312 TP304 when specs are written around 304/304L chemistry and allowables.
Versus TP316: Mo-bearing grades resist chlorides and reducing media better. Do not use TP201 as a drop-in for A312 TP316 or A312 TP316L in seawater or brine service. Prefer Mo austenitic or duplex if chlorides dominate.
Oxidizing versus reducing media: Chromium-rich passive films help in many oxidizing environments. Strongly reducing acids, high chloride concentrations, crevice geometries, and stagnant seawater are poor matches for lean-nickel 201. Local corrosion (pitting and crevice attack) risk rises where chlorides concentrate under deposits or in poorly drained pockets.
Surface condition: Proper pickling and passivation after fabrication help restore a clean passive surface and remove free iron from handling. Mill annealed-and-pickled pipe already carries a descaled surface; site welding and grinding should be cleaned and passivated when the end-user specification requires it. Corrosion performance always depends on the actual fluid, temperature, velocity, and fabrication cleanliness—not on grade name alone.
Applications of ASTM A312 TP201 Pipe
TP201 pipe is selected where austenitic stainless behavior, ASTM A312 product form, and a leaner nickel chemistry are acceptable for the fluid and temperature. Typical application areas include the uses summarized below; always confirm fluid compatibility before substituting 201 for an 18-8 or Mo-bearing grade already written into the datasheet.
| Application area | Typical use of TP201 pipe | Selection note |
|---|---|---|
| Utility and process piping | Water, air, mild chemical transfer lines ordered to ASTM A312 | Confirm fluid compatibility with 201 chemistry |
| Structural / architectural | Handrail, support, and decorative pipe ordered as A312 product | Higher minimum yield versus TP304 can help section design |
| Food-contact and light process | Lines where 201 stainless is accepted by the end-user specification | Follow hygiene finish and welding procedure requirements |
| Transportation / OEM | Frames and piping kits converting to A312 documentation | Dual A312/SA-312 marking often requested for Code Book work |
| General corrosive service | Mild to moderate environments without heavy chlorides | Prefer TP316/TP316L or higher alloys if chlorides dominate |
| High-temperature general service | Lines where A312 austenitic pipe is specified and 201 chemistry is accepted | Review sensitization risk for intermittent high-temperature exposure after welding |
When the same plant also uses 18-8 plate, buyers sometimes standardize documentation by pairing TP201 pipe with SA240, or by staying entirely in the 304 family with A312 TP304 and matching plate. Match the grade family to corrosion and code needs first; nickel-cost savings are secondary to fitness for service.
Weldability
TP201 is generally weldable by common austenitic fusion processes with suitable heat input, interpass, and cleanliness. The process choice should follow the qualified WPS for the wall thickness and joint design on the project, not a catalogue preference alone.
- GTAW (TIG) — preferred for root passes and thin-wall pipe where weld metal cleanliness and heat-input control matter
- GMAW (MIG) — productive for fill and cap passes on thicker walls when procedures are qualified
- SMAW — widely used for field girth welds with coated austenitic electrodes selected by agreement
- Automatic orbital or mechanized GTAW — common for repetitive hygienic or high-integrity girth joints
With C up to 0.15%, evaluate HAZ sensitization for carbide-precipitation exposure after welding. Low heat input, controlled interpass, or post-weld anneal / lower-carbon alternatives are engineering choices—not automatic ASTM A312 requirements on every order.
Filler metal: ASTM A312 Table 6 shows the filler recommendation for TP201 as “…” (no AWS classification listed). Filler selection is by agreement—typically a matching 201-type consumable or an approved higher-alloy austenitic consumable documented on the WPS/PQR. Do not treat ER308 or ER308L as mandatory Table 6 filler for TP201. Record the agreed AWS (or EN) consumable on the welding procedure. Note that mill longitudinal welds for WLD and HCW product are made without filler metal; Table 6 guidance applies to joining with filler, not to the mill autogenous weld.
Girth welds follow the piping/vessel code (e.g. ASME B31 / Section IX) and are separate from mill hydro/NDE. Specify girth NDE on fabrication documents when required. Keep joints clean of oil, paint, and carbon-steel contamination.
Surface Finishes
Surface condition for ASTM A312 TP201 pipe is stated on the order. Typical mill finishes include the options below; each should be named explicitly so the mill and receiving inspection share the same acceptance language.
- Annealed and pickled (AP) — solution annealed, descaled in acid pickle or an equivalent process, producing a matte gray finish common for process and utility pipe
- Bright annealed (BA) — annealed in a protective atmosphere to a brighter surface where the order allows and mill capability exists for the size
- Mechanically polished — for example 180#, 320#, or 400# grit, or Ra-controlled polish on OD and/or ID for hygienic or architectural duty; polishing does not replace solution annealing
- Bead-finished welded OD — weld bead rolled or ground flush as agreed for WLD/HCW product
Passivation after pickle or polish can be added when the end-user specification requires it. For food or pharmaceutical lines, state both the Ra (or grit) target and the documentation package—including any surface roughness reports—on the enquiry. SHH STEEL will not imply a polished hygienic finish on standard AP pipe unless the purchase order says so. End preparation (plain or beveled) should be ordered together with finish so that bevel faces and ID cleanliness meet the same acceptance language.
Inspection and Testing
Base inspection and testing for ASTM A312 TP201 pipe combines chemistry, mechanical, and integrity checks. The following items form the usual acceptance package; supplementary requirements apply only when written on the purchase order.
- Heat (melting) analysis — mandatory per heat against Table 1 for TP201 (UNS S20100)
- Product analysis — when ordered (Suppl. S1 / purchase-order language), using A480 Table A1.1 tolerances via A999 §6.3
- Tension test — Table 4 tensile, yield, and elongation on a lot basis
- Flattening test — or alternate bend where the standard permits for certain welded pipe
- Hydrostatic test or nondestructive electric test — each length; manufacturer’s option unless the order fixes the method
- Visual and dimensional check — against ordered NPS/schedule or OD/wall and the applicable tolerance clauses
Mill test certificates: EN 10204 3.1 is the standard documentation package from SHH STEEL supply. EN 10204 3.2 or third-party witness (SGS, Bureau Veritas, TÜV, or the buyer’s nominated agency) is arranged when specified. Dual ASTM A312 / ASME SA-312 certification is available when chemistry, heat treatment, mechanical tests, and marking satisfy both independent editions named on the order.
Optional / supplementary: PMI, RT/UT, intergranular corrosion or weld-decay tests, tighter straightness, special marking—only when listed on the PO. Keep heat numbers on cut pieces for MTC traceability so receiving inspection can clear each length against the certificate without re-identifying the heat.
Packaging and Shipping
Export and domestic shipments of ASTM A312 TP201 pipe are packed for handling and ocean or land transport. Typical practices include the measures below; state any stricter finish-protection or marking rules on the enquiry so packing matches the end-user receiving checklist.
- Seaworthy bundles — pipes strapped or cradled in bundles sized for container or break-bulk handling, with separators where needed to protect finish
- End caps / protectors — plastic or metal caps on plain or beveled ends to reduce damage and contamination during transit
- Marking — durable marking of grade (TP201), heat number, size (NPS or OD × wall / schedule), manufacturing type (SML / WLD / HCW), and mill identity as required by ASTM A312 and the purchase order
- Export packing — waterproof wrapping or tarpaulin as agreed for polished or sensitive finishes; container stuffing photos on request
Shipment docs typically include packing list, invoice, B/L or AWB, and MTC (3.1 or 3.2), plus origin/customs papers per Incoterms. State destination, packing preference, and extra marking at enquiry so the documents and the stencil language stay aligned from mill gate to site receiving.
Why Choose SHH STEEL
SHH STEEL supplies specification-driven stainless plate and pipe. For ASTM A312 TP201 we emphasize chemistry and tensile reported to A312 Table 1 and Table 4 for TP201 (S20100), not vague “201” catalog sheets, so receiving inspection can clear the heat against the ordered edition without chasing missing nitrogen or manganese data. Heat identity stays unbroken from the melt to the finished length, and we check supplier certificates before shipment for wrong UNS labels, out-of-range Mn/Ni, or anneal statements that do not match Table 2.
- Specification fidelity — chemistry and tensile to ASTM A312/A312M Table 1 and Table 4 for TP201 (S20100)
- Mill resources — SML, WLD, and HCW from qualified stainless pipe mills with heat traceability
- Documentation — EN 10204 3.1 MTCs standard; 3.2 or third-party inspection on request
- Dual marking — ASTM A312 and ASME SA-312 when the heat and tests meet both independent editions you name
- Related forms — pipe aligned with SA240 when projects buy both
- Export packing — seaworthy bundles, end protectors, and durable grade/heat/size/type marking
Quotations follow your PO language. Grade hub: A312/A312M Sister ASME Code Book page for the same chemistry (separate standard): SA312 TP201.
Supply Capability
SHH STEEL can supply ASTM A312 TP201 stainless steel pipe against the edition and manufacturing type named on your enquiry. The capability table below summarizes the routes, sizes, finishes, and documents we regularly quote for this grade; the Stock / Available sizes block under Dimensions lists representative NPS and schedule combinations for stock enquiry.
| Item | SHH STEEL capability for TP201 |
|---|---|
| Standard | ASTM A312 / A312M Grade TP201 (UNS S20100); optional dual mark with ASME SA-312 when PO requires |
| Manufacturing types | SML, WLD, HCW |
| Size | NPS 1/8 and up per ASME B36.19; special OD/wall by agreement |
| Schedules | 5S, 10S, 40S, 80S and non-standard walls |
| Length | SRL, DRL, or cut-to-length |
| Finish | Annealed and pickled, bright annealed, polished by agreement |
| Testing | Tension (75/38 ksi), flattening/bend, hydro or NDE per length; supplementary tests on order |
| Documents | EN 10204 3.1; third-party inspection / 3.2 on request |
| Trade terms | FOB / CFR / CIF / EXW and other agreed Incoterms |
Stock moves with mill rolling cycles. Enquiries should state China origin preference if applicable, ASTM A312/A312M Grade TP201 (UNS S20100), SML/WLD/HCW, NPS or OD × wall, length practice, finish, and any product-analysis or 3.2 requirements, so mill slots line up with your need date. Cut lengths, beveling, and packing-list marking are available on confirmed orders. Browse related grades on A312/A312M
FAQ
-
Is ASTM A312 the same as ASME SA-312 for TP201?
- ASTM A312/A312M and ASME SA-312/SA-312M are two independent standards. For a given referenced edition, chemistry (Table 1), tensile (Table 4), manufacturing types, and most testing language often match, which is why dual A312/SA-312 marking is common when the purchase order names both. Still order and mark the governing standard explicitly—do not treat the titles as synonyms on the MTC or stencil.
-
TP201 vs TP304 — which ASTM A312 grade should I order?
- Order ASTM A312 TP201 when lean-nickel Mn–N chemistry (UNS S20100) and the 38 ksi minimum yield are accepted for the fluid and temperature. Order TP304 or TP304L when the project datasheet, allowables, or owner preference is written around classic 18-8 chemistry. They share a 75 ksi tensile floor but are not automatic drop-in replacements without engineered approval.
-
How does ASTM A312 TP201 differ from TP201LN?
- They are different UNS numbers with different Table 1 and Table 4 rows. TP201 is UNS S20100 with C ≤0.15% and 75/38 ksi minima; TP201LN is UNS S20153 with C ≤0.03%, controlled nitrogen, tighter sulfur, a copper maximum, and 95/45 ksi minima. Order the exact design grade on the purchase order and do not interchange certificates.
-
What is the maximum wall or NPS for ASTM A312 TP201?
- ASTM A312 does not publish a single marketing maximum wall or NPS for TP201. Feasible size depends on manufacturing type (SML versus WLD/HCW), mill tooling, ASME B36.19 schedules, and special OD/wall by agreement. Confirm the NPS, schedule or wall, and route on enquiry before treating any catalogue ceiling as a hard limit.
-
Seamless vs welded ASTM A312 TP201 — which is better?
- Neither route is universally better. Seamless is usual for heavy walls, high pressure, and owner specs that exclude longitudinal seams; welded and HCW cover common NPS and schedule combinations efficiently when the code accepts welded austenitic pipe. Choose the manufacturing type your design code and datasheet allow, and verify SML, WLD, or HCW on the mill test certificate.
-
Can you dual-certify ASTM A312 and ASME SA-312 TP201?
- Yes, when heat analysis, heat treatment, mechanical tests, and marking meet both independent editions named on the purchase order. Dual marking is optional documentation language, not a reason to merge A312 and SA-312 into one title on the website product page or the Standard parameter block. State both editions clearly if Code Book piping requires SA-312 alongside ASTM A312.
-
Hydrostatic test vs NDE on ASTM A312 TP201 — which do I get?
- Each finished length is hydrostatically tested or nondestructively electrically tested per ASTM A312. The manufacturer may choose the method unless the purchase order fixes one. If your project or end-user specification requires hydro only, or a named NDE method, write that requirement on the order so the certificate and stencil match receiving inspection expectations.
-
Does ASTM A312 Table 4 specify hardness for TP201?
- No. Table 4 lists tensile strength, yield strength, and elongation for TP201 but does not list a hardness maximum. Catalogue Brinell or Rockwell figures are not specification-mandatory acceptance items. If hardness matters for fabrication or end-user checks, state the limit on the purchase order and verify it on the mill test certificate.
-
What filler metal should I use to weld ASTM A312 TP201 pipe?
- ASTM A312 Table 6 lists “…” for TP201, meaning filler is by agreement rather than a mandatory AWS classification such as ER308. Typical practice uses a matching 201-type or an approved higher-alloy austenitic consumable documented on the WPS/PQR. Mill WLD and HCW longitudinal welds are made without filler; Table 6 guidance applies to joining with filler, not to the mill autogenous weld.
-
What heat treatment does ASTM A312 require for TP201?
- All ASTM A312 pipe shall be heat treated. For TP201, which has no individual Table 2 temperature row, the default minimum solution-annealing temperature is 1900 °F [1040 °C], followed by water quenching or another rapid cool that prevents harmful carbide reprecipitation. Ask the mill to state anneal temperature and quench method on the EN 10204 3.1 certificate.
-
What sizes of ASTM A312 TP201 pipe can SHH STEEL supply?
- We regularly quote NPS from about 1/2 through 24 in Sch 10S, 40S, and 80S (also 5S where tooling allows), plus special OD/wall and cut lengths by agreement. Treat the Stock / Available sizes block as an enquiry range that moves with mill rolling cycles—not a fixed warehouse SKU list or tonnage claim. State manufacturing type, finish, and wall basis (nominal or minimum) when you enquire.
-
Do you supply related plate in UNS S20100 with ASTM A312 TP201 pipe?
- Yes—related flat product is available as ASME SA240 UNS S20100 stainless steel plate when projects buy both forms. Order pipe to ASTM A312/A312M and plate to the applicable plate specification separately, and keep heat chemistry language consistent across forms without assuming plate test requirements substitute for pipe Table 4 or hydro/NDE.
Conclusion
ASTM A312 TP201 (UNS S20100) is the lean-nickel austenitic pipe grade in ASTM A312/A312M for high-temperature and general corrosive service when manganese–nitrogen chemistry is accepted. Order the manufacturing type (SML/WLD/HCW), schedule or wall, finish, and any product analysis or supplementary tests explicitly, and keep ASME SA-312 dual marking as an optional Code Book requirement rather than a merged title. For stock checks, cut-length packages, or mill certificates, contact SHH STEEL at admin@steelspecs.com or browse the ASTM A312/A312M category on steelspecs.com.