ASME SA213 TP316Ti Stainless Steel Tube
What is ASME SA213 TP316Ti Stainless Steel Tube
ASME SA-213 / SA-213M is the ASME Boiler and Pressure Vessel Code Book adoption of the seamless ferritic and austenitic alloy-steel boiler, superheater, and heat-exchanger tube product text. When Code-stamped exchangers, boilers, or registered systems invoke that adoption by name, SA-213 is the governing product standard for titanium-stabilized Mo tube — an independent Code Book line, not a merged title with ASTM A213. Use SA213/SA213M as the series entry point.
Grade TP316Ti / UNS S31635 is the titanium-stabilized molybdenum austenitic row inside that SA-213 stainless family. Three melt lines separate it from ordinary TP316 before tensile review: silicon capped at 0.75% rather than 1.00%, nitrogen capped at 0.10% instead of an ellipsis, and titanium required at ≥5 × (C + N) while staying ≤0.70%. Molybdenum 2.00–3.00% remains mandatory. Casing on this site is TP316Ti (not TP316TI).
SHH STEEL can supply ASME SA213 TP316Ti as seamless cold-finished and hot-finished tube in the usual OD × wall / BWG band, with EN 10204 3.1 certificates that report Mo, N, Ti against the 5×(C+N) rule, and Si ≤0.75%. Dual SA-213/A213 marking is added only when the purchase order asks; the live twin is A213 TP316Ti.
Shop names include “316Ti,” “S31635,” and “Ti-stabilized 316 Mo tube.” Helpful for routing; the purchase order should still carry ASME SA-213 Grade TP316Ti / UNS S31635, wall basis, OD × wall or BWG, finish route, and any Supplementary Requirements (including stabilizing holds when ordered). Sister SA213 pages include SA213 TP316, SA213 TP316L, SA213 TP316H, and SA213 TP321 when Ti stabilization is wanted without Mo. Seamless only — no Manufacturing Types (SML / WLD / HCW) H2.
Chemical Composition of SA213 TP316Ti
Two chemistry layers matter for TP316Ti under ASME SA-213. Melting (heat or ladle) analysis is mandatory for every heat; product analysis on finished tube applies only when Supplementary Requirement wording or the purchase order invokes it through the general requirements (commonly ASTM A1016/A1016M). Product-analysis tolerances typically flow from ASTM A480/A480M Table A1.1. Reviewers should verify Si ≤0.75%, N ≤0.10%, Mo 2.00–3.00%, and Ti ≥5 × (C + N) ≤0.70% together — Mo alone does not make a heat S31635.
UNCERTAIN: exact SA-213 / A213 edition year; stainless chemistry table number; A480 Ti max product-tolerance digits (0.05 over on the ≤0.70 / Ti-to-1.00 band practice applied here); full S2 stabilizing-hold temperature/time wording when that Supplementary Requirement is ordered — confirm on the ordered edition.
Melting analysis
| Element | TP316Ti (UNS S31635) melting analysis |
|---|---|
| Carbon (C) | ≤ 0.08 |
| Manganese (Mn) | ≤ 2.00 |
| Phosphorus (P) | ≤ 0.045 |
| Sulfur (S) | ≤ 0.030 |
| Silicon (Si) | ≤ 0.75 |
| Chromium (Cr) | 16.0 – 18.0 |
| Nickel (Ni) | 10.0 – 14.0 |
| Molybdenum (Mo) | 2.00 – 3.00 |
| Nitrogen (N) | ≤ 0.10 |
| Titanium (Ti) | ≥ 5 × (C + N), ≤ 0.70 |
That melt table is the acceptance chemistry for every heat of SA213 TP316Ti. Titanium must clear five times the sum of carbon plus nitrogen and must not exceed 0.70%. Because N has an explicit maximum, the Ti minimum moves with both C and N on the heat — a certificate that reports Ti without C and N cannot prove the 5× rule. Silicon at ≤0.75% is intentionally tighter than the 1.00% cap on TP316 / TP316L / TP316H.
Product analysis (when required)
| Element | Melting | Tolerance (A480 A1.1) | Product analysis limit |
|---|---|---|---|
| Carbon (C) | ≤ 0.08 | 0.01 over | ≤ 0.09 |
| Manganese (Mn) | ≤ 2.00 | 0.04 over | ≤ 2.04 |
| Phosphorus (P) | ≤ 0.045 | 0.010 over | ≤ 0.055 |
| Sulfur (S) | ≤ 0.030 | 0.005 over | ≤ 0.035 |
| Silicon (Si) | ≤ 0.75 | 0.05 over | ≤ 0.80 |
| Chromium (Cr) | 16.0 – 18.0 | 0.20 under / over | 15.80 – 18.20 |
| Nickel (Ni) | 10.0 – 14.0 | 0.10 under / 0.15 over | 9.90 – 14.15 |
| Molybdenum (Mo) | 2.00 – 3.00 | 0.05 under / 0.10 over | 1.95 – 3.10 |
| Nitrogen (N) | ≤ 0.10 | 0.01 over | ≤ 0.11 |
| Titanium (Ti) | ≥ 5 × (C+N), ≤ 0.70 | 0.05 over on max (Ti to 1.00 band practice) | max ≤ 0.75 product; min tied to heat C+N |
When product analysis is invoked, A480 tolerances apply as shown. Titanium’s product maximum uses the 0.05-over practice associated with Ti-to-1.00 bands in A480 — treated as UNCERTAIN digit confirmation on the ordered A480 path. The Ti minimum on product check remains tied to the heat’s C+N through the 5× rule.
Snapshot vs sister grades
| Element | TP316L (S31603) | TP316Ti (S31635) | TP321 (S32100) |
|---|---|---|---|
| C | ≤ 0.035 | ≤ 0.08 | ≤ 0.08 |
| Si | ≤ 1.00 | ≤ 0.75 | ≤ 1.00 |
| Mo | 2.00 – 3.00 | 2.00 – 3.00 | … (no requirement) |
| N | … | ≤ 0.10 | … |
| Ti | … | ≥ 5 × (C+N), ≤ 0.70 | ≥ 5 × (C+N), ≤ 0.70 |
Against SA213 TP316L, Ti stabilization replaces the L-carbon path for sensitization resistance while allowing C up to 0.08% and requiring the Ti formula. Against SA213 TP321, both share the Ti ≥5×(C+N) ≤0.70 idea, but only TP316Ti carries Mo 2–3% and the tighter Si/N caps. Against SA213 TP316H, Ti stabilization is not a substitute for H-grade carbon floor and grain-size mandates.
Mechanical Properties of SA213 TP316Ti
ASME SA-213 sets the tensile acceptance floor for TP316Ti at 75 ksi [515 MPa] tensile strength and 30 ksi [205 MPa] yield strength (0.2% offset), with elongation of 35% minimum in 2 in. or 50 mm and hardness capped at 192 HBW / 200 HV or 90 HRB. Those floors match the standard 316-family mechanical row; grade distinction sits in Ti stabilization, Si/N caps, and Mo — not in a higher tensile number.
| Property | TP316Ti requirement |
|---|---|
| Tensile strength, min (Table 4) | 75 ksi [515 MPa] |
| Yield strength (0.2% offset), min (Table 4) | 30 ksi [205 MPa] |
| Elongation in 2 in. or 50 mm, min (Table 4) | 35% |
| Hardness, max (Table 4) | 192 HBW / 200 HV or 90 HRB |
| Grain size | No mandatory ASTM grain-size number in the public heat-treatment table for TP316Ti |
Public heat-treatment excerpts used for this pack do not print a mandatory ASTM grain-size number for TP316Ti the way H-grades do. Do not invent a No. 7 clause on the MTC unless the ordered edition or purchase order requires one. Hardness and tensile review still use the 192 HBW / 75/30 ksi 316-family caps.
Flattening, flaring, and reverse-bend tests follow SA-213 / general-requirements practice. Hydrostatic testing or NDE is selected per specification and PO. Dual-marked jobs still clear SA-213 mechanical text — see A213 TP316Ti.
Dimensions and Tolerances
Dimensional supply for ASME SA213 TP316Ti is tube language — outside diameter × wall thickness (minimum wall or average wall) and, commercially, BWG / gauge — not ASME B36.19 pipe schedules as the primary size story. Usual SA-213 sizes run from about 1/8 in. [3.2 mm] inside diameter to 5 in. [127 mm] outside diameter, with minimum wall from about 0.015 to 0.500 in. [0.4 to 12.7 mm]; other diameters may be furnished when all other requirements are met.
Heat-exchanger and process datasheets that pick Ti-stabilized Mo tube usually assume minimum wall — state wall basis on the purchase order. Outside-diameter and wall variations follow the general requirements invoked by SA-213 (commonly ASTM A1016/A1016M). Cold-finished tubes commonly hold tighter OD; hot-finished tubes allow wider windows.
| Item | Typical SA213 TP316Ti dimensional practice |
|---|---|
| Product form | Seamless only (cold-finished or hot-finished) |
| Usual size band | ~1/8 in. [3.2 mm] ID to 5 in. [127 mm] OD; wall ~0.015–0.500 in. [0.4–12.7 mm] |
| Wall basis | Minimum wall (common for HX datasheets) or average wall if PO says so |
| OD / wall tolerance | Per general requirements (commonly A1016/A1016M) for the ordered finish |
| Length | Straight random / cut-to-length; U-bend by agreement |
BWG / gauge callouts are accepted on enquiry; certificates should still show OD and wall in inch or millimetre units. U-bends and polished ID finishes are commercial options on top of SA-213 dimensional rules — they do not replace Ti-formula chemistry or minimum-wall discipline.
Equivalent Grades
Equivalence talk around TP316Ti must keep the Ti formula, Mo band, and Si/N caps intact. ASME SA-213 Grade TP316Ti / UNS S31635 is the governing designation for this article; “316Ti or 321” on a drawing is not automatic interchange.
| Designation | Notes |
|---|---|
| ASME SA-213 / SA-213M Grade TP316Ti | Governing ASME Code Book seamless boiler / HX tube product standard for this article |
| UNS S31635 | Unified number in the stainless chemistry table |
| ASTM A213 TP316Ti | Separate ASTM product specification — dual-mark only when the PO asks |
| Related Mo grade | SA213 TP316 — same Mo band, no Ti formula, Si ≤1.00 |
| Related L-grade | SA213 TP316L — C ≤0.035, no Ti |
| Related Ti grade | SA213 TP321 — Ti formula without Mo |
| Related plate | A240 / SA240 flat product in the 316Ti family — order plate and tube under their own standards |
If a datasheet says “316Ti or equivalent,” confirm Ti ≥5×(C+N) ≤0.70, Mo 2–3, Si ≤0.75, N ≤0.10, and SA-213 naming. Plate under A240 / SA240 does not automatically qualify as SA-213 tube. Non-Code ASTM purchase: A213 TP316Ti.
Heat Treatment and Delivery Condition
TP316Ti under ASME SA-213 is furnished solution treated at a minimum of 1900 °F [1040 °C], then quenched in water or cooled rapidly by other means. That heat-treatment row applies to both cold-finished and hot-finished seamless tube. Public excerpts used here do not attach a mandatory ASTM grain-size number to TP316Ti; do not invent one on the certificate unless the ordered edition or PO requires it.
Cold-finished versus hot-finished is a process and dimensional route, not a substitute for the solution anneal. Delivery condition for SHH STEEL TP316Ti is solution annealed and pickled (or bright annealed by agreement), with anneal temperature, quench method, Mo, N, and Ti (with C+N for the 5× check) on the EN 10204 3.1 certificate.
When Supplementary Requirement S2 (or edition-equivalent stabilizing wording) is ordered, a stabilizing heat treatment after the high-temperature solution anneal may be required — exact temperature and time wording is UNCERTAIN pending the ordered edition’s S2 text. Name S2 explicitly on the purchase order if the project needs that stabilizing hold; do not assume every TP316Ti shipment includes it by default.
Corrosion Resistance
TP316Ti pairs molybdenum’s localized-corrosion benefit with titanium stabilization so carbon is tied up as titanium carbides/carbonitrides rather than chromium carbides at grain boundaries. That is why buyers choose it for welded heat-exchanger and process tube where sensitization resistance is needed but L-carbon chemistry is not the named path — or where European / project specs historically call 316Ti.
Molybdenum 2–3% still improves chloride pitting resistance relative to non-Mo Ti grades such as TP321. Titanium stabilization is not a license to ignore heat tint, contamination, or wrong filler on aqueous chloride duty, and it is not a creep H-grade substitute for TP316H.
Selection honesty: for lowest carbon as-welded IGC path see SA213 TP316L; for creep-oriented H carbon and grain size see SA213 TP316H; for Ti without Mo see SA213 TP321.
Applications of SA213 TP316Ti Tube
TP316Ti is ordered for Code and near-Code heat-exchanger, condenser, and process-tube circuits that specify titanium-stabilized molybdenum austenitic seamless tube — often where welded fabrication and sensitization resistance matter and the project language says 316Ti / S31635 rather than 316L. Boiler / superheater use appears when the datasheet names the grade; H-grade creep duty usually points elsewhere.
Enquiry patterns ask for seamless cold-finished HX OD × minimum-wall tube, sometimes with ID polish or U-bends for bundle replacement. Hot-finished seamless remains available when size favors it. MTC review should always show Ti with C and N so the 5× rule can be checked.
Sister steering: plain Mo → SA213 TP316; L-carbon → SA213 TP316L; H-grade Mo → SA213 TP316H; Ti without Mo → SA213 TP321.
Weldability
TP316Ti tube welds with matching or near-matching Mo-bearing austenitic filler selected for stabilized service (fabricator WPS may call ER316L / ER316LSi or Ti-aware selections depending on project rules). Titanium in the base metal helps resist sensitization in the HAZ when heat input is controlled, but it does not remove the need for clean practice and appropriate filler for chloride or process duty.
Tube-to-tubesheet procedures should name TP316Ti / S31635. Do not assume a TP321 WPS covers Mo-bearing 316Ti without review, and do not treat TP316Ti as an automatic TP316H substitute on creep datasheets. If S2 stabilizing treatment after fabrication is required, state it on the project specification and purchase order.
Dual SA-213/A213 marking does not change filler selection. When the dominant need is L-carbon as-welded IGC rather than Ti stabilization, many stewards simply order TP316L instead of forcing a Ti path.
Surface Finishes
Standard mill delivery for ASME SA213 TP316Ti is solution annealed and pickled, leaving a clean matte finish suitable for heat-exchanger and process-tube duty. Bright annealing is available by agreement when OD appearance or polish steps favor it.
ID/OD polish and U-bend conditioning are commercial additions — they do not replace Ti-formula chemistry, Mo, or anneal reporting. End caps and dry export packaging matter more than paint on pickled stainless.
SHH STEEL notes the ordered surface route on the packing list and aligns it with the MTC finish description for receiving inspection.
Inspection and Testing
Base ASME SA-213 testing for TP316Ti includes heat analysis (Mo 2.00–3.00%, N ≤0.10%, Si ≤0.75%, Ti ≥5×(C+N) ≤0.70%), tension tests to 75/30 ksi floors, hardness to 192 HBW / 90 HRB, and flattening / flaring tests for the ordered size. Hydrostatic testing or NDE follows the path selected on the purchase order.
Certificate reviewers should recalculate 5 × (C + N) against reported Ti rather than trusting a “Ti present” checkbox. Product analysis, when ordered, applies A480 tolerances including the Ti max practice noted as UNCERTAIN digit confirmation above.
Supplementary Requirements (including S2 stabilizing holds when named), A262 practices by agreement, and third-party witness are available on request. EN 10204 3.1 is default; 3.2 when required. Dual SA-213/A213 names appear only when dual marking was ordered.
Packaging and Shipping
TP316Ti tube leaves SHH STEEL bundled, capped or end-protected, and tagged for export or domestic delivery according to length mix and bend form. Bundle tags repeat ASME SA-213 Grade TP316Ti, UNS S31635, heat number, size, and wall basis so receivers can match the 3.1 certificate — including Ti, C, and N — without opening every bundle.
Export packing uses seaworthy bundling appropriate for pickled stainless. Marking follows SA-213 and any dual-mark text the PO adds, referencing A213 TP316Ti only when dual ASTM marking was ordered.
Why Choose SHH STEEL
SHH STEEL treats ASME SA213 TP316Ti as a Code Book Ti-stabilized Mo product with enforceable Si ≤0.75%, N ≤0.10%, Mo 2–3%, Ti ≥5×(C+N) ≤0.70%, tensile, hardness, and marking rules — not as “316 with a titanium addition” checked only by PMI Ti peak. Enquiry review recalculates the Ti formula before release.
That stops silent substitution with TP316, TP316L, or TP321 heats on datasheets that actually require S31635. We keep SA-213 and A213 independent, dual-mark only on request, and put Mo + N + Ti + C on the 3.1 certificate so inspectors can verify the 5× rule.
Cross-links: SA213 TP316, SA213 TP316L, SA213 TP316H, SA213 TP321, hub SA213/SA213M.
Supply Capability
SHH STEEL can supply ASME SA213 TP316Ti stainless steel tube against the edition and finish route named on your enquiry. The capability table below summarizes sizes, finishes, and documents we regularly quote, followed by the Stock / Available sizes map for Ti-stabilized Mo heat-exchanger and process tube.
| Item | SHH STEEL capability for TP316Ti |
|---|---|
| Standard | ASME SA213 / SA213M (dual A213 marking on request) |
| Grade | TP316Ti / UNS S31635 |
| Product form | Seamless only — cold-finished and hot-finished |
| Size | Typical OD × min wall (or average wall) in the SA-213 usual band; other diameters by agreement |
| Wall / gauge | Minimum wall or average wall; BWG / gauge callouts accepted on enquiry |
| Length | Cut-to-length for HX / process bundles; U-bend by agreement |
| Documentation | EN 10204 3.1 MTC with Mo + N + Ti + C (5× check); S2 / A262 / witness on request |
| Trade terms | FOB / CFR / CIF / EXW and other agreed Incoterms |
Stock / Available sizes
SHH STEEL quotes TP316Ti against a stock-and-mill enquiry range rather than a frozen SKU or tonnage list. Representative OD × wall / BWG combinations below are an enquiry map for heat-exchanger and process tube — confirm live availability and cut lengths on the RFQ.
| OD (in.) | Typical wall / BWG enquiry band | Notes |
|---|---|---|
| 1/2 – 1 | BWG 16–12 / ~0.065–0.109 in. | Small HX / instrument sizes |
| 1-1/4 – 2 | BWG 14–10 / ~0.083–0.134 in. | Common process exchanger band |
| 2-1/2 – 3 | 0.120 – 0.250 in. min wall | Heavier HX wall |
| 3-1/2 – 5 | 0.180 – 0.300 in. min wall | Upper usual SA-213 OD by agreement |
Send OD × wall (or BWG), wall basis, quantity, finish route, any S2 stabilizing requirement, and whether dual A213 marking is required. SHH STEEL returns capability against ASME SA213 TP316Ti / UNS S31635 — not a TP316 or TP321 substitute.
FAQ
-
Is ASME SA-213 the same as ASTM A213 for TP316Ti?
- No. ASME SA-213 / SA-213M is the ASME Code Book adoption; ASTM A213 / A213M is the separate ASTM product specification. Chemistry — including the Ti ≥5×(C+N) rule — tensile, and hardness floors align closely for a given referenced edition, but they remain independent standards. Dual-mark only when the purchase order asks for both names on the stencil and MTC.
-
Does ASME SA213 TP316Ti include welded or HCW tube?
- No. This SA213 product page covers seamless boiler, superheater, and heat-exchanger tube only. SA-213 for the austenitic grades discussed here is a seamless tube product form; welded (WLD) and hot-finished continuous-welded (HCW) manufacturing-type labels from pipe standards are not used as product-form options on this pack. If your datasheet actually needs welded stainless pipe, that is a different product-standard family and should be ordered under the matching pipe specification.
-
What is the UNS number and chemistry focus of ASME SA213 TP316Ti?
- UNS S31635. Check C ≤0.08%, Si ≤0.75%, Cr 16.0–18.0%, Ni 10.0–14.0%, Mo 2.00–3.00%, N ≤0.10%, and Ti ≥5 × (C + N) ≤0.70% together. Silicon and nitrogen caps plus the Ti formula are what separate this row from ordinary TP316. Product analysis, when ordered, applies A480 A1.1 tolerances.
-
TP316Ti vs TP316L — which SA213 tube should I order?
- Order TP316L when the datasheet wants C ≤0.035% as the sensitization path without Ti. Order TP316Ti when it wants titanium stabilization with Mo 2–3%, Si ≤0.75%, N ≤0.10%, and C ≤0.08% under the 5×(C+N) Ti rule. Both can serve welded aqueous duty, but they are different chemistries — not dual stamps.
-
TP316Ti vs TP321 — both are Ti-stabilized, so are they interchangeable under SA213?
- No. Both use Ti ≥5×(C+N) ≤0.70, but TP316Ti requires Mo 2.00–3.00% and tighter Si/N caps, while TP321 has no Mo requirement and allows Si ≤1.00%. Chloride pitting expectations diverge. Interchange only with engineering approval when Mo is truly optional on the datasheet.
-
Why is silicon capped at 0.75% on SA213 TP316Ti?
- The stainless chemistry table for TP316Ti / S31635 sets Si ≤0.75%, tighter than the 1.00% cap on TP316 / TP316L / TP316H. A heat at 0.90% Si that would pass TP316 fails TP316Ti. Certificate review should check Si together with Mo, N, and the Ti formula.
-
How is the titanium minimum calculated for SA213 TP316Ti?
- Titanium must be at least five times the sum of carbon plus nitrogen, and not more than 0.70% on melting analysis. Because N has an explicit ≤0.10% maximum, both C and N on the heat affect the Ti floor. MTCs should report C, N, and Ti so inspectors can verify 5 × (C + N) ≤ Ti ≤ 0.70.
-
Does SA-213 set a hardness limit for TP316Ti?
- Yes. Table 4 caps hardness at 192 HBW / 200 HV or 90 HRB, with 75 ksi tensile, 30 ksi yield, and 35% elongation — the standard 316-family mechanical row. Grade distinction is chemical (Ti/Si/N/Mo), not a higher tensile floor.
-
What heat treatment does ASME SA-213 require for TP316Ti?
- Solution treatment at a minimum of 1900 °F [1040 °C] with water quench or other rapid cool. Public excerpts used here do not mandate an ASTM grain-size number for TP316Ti. If Supplementary Requirement S2 stabilizing treatment is needed after the high-temperature anneal, name it on the PO — exact S2 temperature/time wording is UNCERTAIN pending the ordered edition.
-
Minimum wall vs average wall — which should I order for SA213 TP316Ti?
- Most heat-exchanger datasheets assume minimum wall; average wall only when the PO says so. Usual SA-213 sizes run about 1/8 in. ID to 5 in. OD with min wall about 0.015–0.500 in.; other diameters by agreement. Prefer OD × wall / BWG language over B36.19 pipe schedules.
-
Can you dual-certify ASME SA-213 and ASTM A213 TP316Ti?
- Yes, when the purchase order asks for dual marking and the heat meets both named editions — including the Ti formula, Mo, Si, and N caps. Dual marking is stencil and documentation practice, not proof the names are synonyms. Otherwise SA-213 stands alone for Code Book jobs.
-
Is TP316Ti a substitute for SA213 TP316H on creep datasheets?
- No. TP316H requires C 0.04–0.10%, Ni floor 11%, and ASTM grain size No. 7 or coarser for H-grade creep-oriented duty. TP316Ti is a Ti-stabilized Mo grade without that H carbon floor or public grain-size mandate. Use TP316H when the datasheet is H-grade; use TP316Ti when it asks for titanium stabilization.
Conclusion
ASME SA213 TP316Ti / UNS S31635 is the titanium-stabilized molybdenum seamless stainless steel tube grade for Code boiler, superheater, and heat-exchanger service when welded or sensitization-sensitive duty needs Mo 2.00–3.00%, Si ≤0.75%, N ≤0.10%, Ti ≥5×(C+N) ≤0.70%, a 75/30 ksi tensile floor, hardness max 192 HBW / 90 HRB, and a 1900 °F solution anneal. SHH STEEL supplies cold-finished and hot-finished seamless tube in the usual OD × wall / BWG band with EN 10204 3.1 MTCs that report Mo, N, Ti, and C for the 5× check. Compare sister grades on the same Code Book spine, or start from SA213/SA213M. Enquire with OD × wall, wall basis, quantity, and document needs at admin@steelspecs.com.