ASTM A213 TP XM-19 Stainless Steel Tube
What is ASTM A213 TP XM-19 Stainless Steel Tube
ASTM A213 / A213M is the ASTM International product specification for seamless ferritic and austenitic alloy-steel boiler, superheater, and heat-exchanger tubes. Grade XM-19 — commercially called Nitronic 50 and listed as UNS S20910 — is the high-strength nitrogen-strengthened austenitic in that stainless table: carbon ≤0.06%, manganese 4.0–6.0%, chromium 20.5–23.5%, nickel 11.5–13.5%, molybdenum 1.50–3.00%, nitrogen 0.20–0.40%, plus niobium and vanadium each 0.10–0.30%. Buyers who write “XM-19 tube,” “S20910 HX tube,” or “Nitronic 50 boiler tube” still need to name A213 (or the separate ASME SA-213 adoption) on the purchase order so the mill applies the tube product standard’s minimum-wall, test, and marking clauses.
SHH STEEL can supply ASTM A213 XM-19 stainless steel tube as seamless cold-finished and hot-finished product in the usual boiler and heat-exchanger OD × wall / BWG band, shipped with EN 10204 3.1 mill test certificates that report the full ladle chemistry — including Nb, V, Mo, and N — and the Table 4 tensile and hardness results. When a project also needs ASME Code Book marking, we dual-mark A213 / SA-213 on the same lengths only if the purchase order says so. Browse the grade family on the A213/A213M hub.
Shop names do not replace XM-19 / S20910 on the MTC or stencil. Sister grades under the same ASTM standard include A213 TP316 / A213 TP316L for molybdenum austenitics at lower strength, A213 TP304 for classic 18-8, and A213 UNS S31254 when PREN must go higher still. A213 covers seamless tube only — no welded or HCW manufacturing type — so cold-finished versus hot-finished is the process choice, not a WLD/HCW stencil letter.
Chemical Composition of A213 XM-19
Two chemistry layers matter for XM-19 under ASTM A213. Melting (heat or ladle) analysis is mandatory for every heat; product analysis on finished tube applies only when Supplementary Requirement wording or the purchase order invokes it through ASTM A1016/A1016M. Product-analysis tolerances typically flow from ASTM A480/A480M Table A1.1. SHH STEEL reports actual ladle values — and product values when ordered — and does not advertise unpublished tighter catalogue windows. Every controlled element on this grade (including Nb, V, Mo, and N) must appear on the certificate; an MTC that omits niobium or vanadium is incomplete for S20910.
The tables below reproduce the heat analysis for XM-19 / UNS S20910 and the product-analysis limits from A480 Table A1.1 tolerances. Values are maximum unless a range is shown. Later A213 editions place austenitic stainless grades in Table 2 (older editions used Table 1); confirm the ordered edition on the purchase order.
Melting analysis (heat / ladle analysis)
| Element | XM-19 (UNS S20910) melting analysis |
|---|---|
| Carbon (C) | ≤ 0.06 |
| Manganese (Mn) | 4.0 – 6.0 |
| Phosphorus (P) | ≤ 0.045 |
| Sulfur (S) | ≤ 0.030 |
| Silicon (Si) | ≤ 1.00 |
| Chromium (Cr) | 20.5 – 23.5 |
| Nickel (Ni) | 11.5 – 13.5 |
| Molybdenum (Mo) | 1.50 – 3.00 |
| Nitrogen (N) | 0.20 – 0.40 |
| Niobium (Nb) | 0.10 – 0.30 |
| Vanadium (V) | 0.10 – 0.30 |
Source: ASTM A213/A213M stainless chemistry table for Grade XM-19 / UNS S20910 (public mill / specification summaries cross-checked — htpipe A213 PDF table text). Confirm the ordered edition. Nitrogen analysis method is a matter of agreement between purchaser and producer per the standard’s nitrogen footnote.
Product analysis — A480/A480M Table A1.1 tolerances applied
| Element | Melting | Tolerance (A480 A1.1) | Product analysis limit |
|---|---|---|---|
| Carbon (C) | ≤ 0.06 | 0.01 over | ≤ 0.07 |
| Manganese (Mn) | 4.0 – 6.0 | 0.05 under / over | 3.95 – 6.05 |
| Phosphorus (P) | ≤ 0.045 | 0.010 over | ≤ 0.055 |
| Sulfur (S) | ≤ 0.030 | 0.005 over | ≤ 0.035 |
| Silicon (Si) | ≤ 1.00 | 0.05 over | ≤ 1.05 |
| Chromium (Cr) | 20.5 – 23.5 | 0.25 under / over | 20.25 – 23.75 |
| Nickel (Ni) | 11.5 – 13.5 | 0.15 under / over | 11.35 – 13.65 |
| Molybdenum (Mo) | 1.50 – 3.00 | 0.05 under / 0.10 over | 1.45 – 3.10 |
| Niobium (Nb) | 0.10 – 0.30 | 0.05 under / over | 0.05 – 0.35 |
| Nitrogen (N) | 0.20 – 0.40 | 0.02 under / 0.04 over | 0.18 – 0.44 |
| Vanadium (V) | 0.10 – 0.30 | 0.03 under / over | 0.07 – 0.33 |
Five lines drive selection: Cr–Ni–Mo for corrosion, and N plus Mn for strength. Niobium and vanadium in the 0.10–0.30% bands help hold strength and refine grain; both are Table requirements, not optional extras. Carbon ≤0.06% is tighter than TP304’s ≤0.08%, which helps as-welded IGC resistance relative to standard-carbon 18-8, though XM-19 is not marketed as an L grade. Versus A213 TP316, XM-19 adds a nitrogen floor, Nb/V, higher Cr, and a much higher tensile/yield pair.
When product analysis is ordered, the A480 A1.1 path widens each band as shown above. Put any tighter project nitrogen, molybdenum, or sulfur ceiling on the purchase order before the heat is selected — nitrogen near the top of the 0.20–0.40% band is often what clears the 100/55 ksi floor with comfortable margin.
Mechanical Properties of A213 XM-19
ASTM A213 Table 4 sets the tensile acceptance floor for XM-19 at 100 ksi [690 MPa] tensile strength and 55 ksi [380 MPa] yield strength (0.2% offset), with elongation of 35% minimum in 2 in. or 50 mm. That yield floor is nearly twice TP316’s 30 ksi under the same product standard — the reason designers look at S20910 when wall thickness, weight, or pressure rating is tight and the fluid still fits an austenitic. Hardness maximum is 250 HBW / 265 HV or 25 HRC, and hardness tests are part of lot acceptance under A213.
| Property | XM-19 requirement (Table 4) |
|---|---|
| Tensile strength, min | 100 ksi [690 MPa] |
| Yield strength (0.2% offset), min | 55 ksi [380 MPa] |
| Elongation in 2 in. or 50 mm, min | 35% |
| Hardness, max | 250 HBW / 265 HV or 25 HRC |
Source: ASTM A213/A213M Table 4 for XM-19 / UNS S20910 (public specification summaries — htpipe A213 PDF, Blackburn Metals A213 tubular excerpt). Mechanical property requirements do not apply to tubing smaller than 1/8 in. [3.2 mm] inside diameter or thinner than 0.015 in. [0.4 mm] wall. Flattening and flaring tests are also required on a lot basis.
Where the governing code lists allowable stresses for S20910, the higher yield can justify a thinner wall or a higher design pressure — but the weld metal and tubesheet joint must be able to match that strength. Do not assume a 308L deposit will clear a 55 ksi design without a qualified WPS and filler selection review. Actual mill certificates often clear the 100/55 ksi floor with margin; design calculations should still use Table 4 unless the PO states higher guaranteed values the mill has accepted in writing.
Dimensions and Tolerances
Dimensional supply for ASTM A213 XM-19 is tube language — outside diameter × wall thickness (minimum wall or average wall) and, commercially, BWG / gauge — not ASME B36.19 pipe schedules as the primary size story. The sizes usually furnished under A213 run from about 1/8 in. [3.2 mm] inside diameter to 5 in. [127 mm] outside diameter, with minimum wall from about 0.015 to 0.500 in. [0.4 to 12.7 mm]; other diameters may be furnished when all other requirements are met. State on the purchase order whether wall is minimum or average.
Outside-diameter and wall variations follow ASTM A1016/A1016M as invoked by A213. Cold-finished tubes commonly hold tighter OD control; hot-finished tubes allow wider OD and wall windows. Permissible variations from a specified average wall for cold-finished tube are often summarized as ±10% of the specified average wall. Confirm the exact A1016 rows for the OD and finish route on the ordered edition.
| Item | Typical A213 XM-19 dimensional practice |
|---|---|
| Product form | Seamless only (cold-finished or hot-finished) |
| Usual size band | ~1/8 in. [3.2 mm] ID to 5 in. [127 mm] OD; wall ~0.015–0.500 in. [0.4–12.7 mm] min (or average wall if PO says so) |
| Wall basis | Minimum wall (default commercial practice) or average wall when specified |
| OD / wall tolerances | Per ASTM A1016/A1016M for the finish route and size; cold-finished average wall often ±10% |
| Length | Cut lengths for HX / boiler bundles, or mill random lengths by agreement |
| Secondary size note | ASME B36.19 schedules may appear only when a buyer asks for a pipe-schedule cross-reference — not as the primary A213 size callout |
Because designers often thin the wall to exploit the 55 ksi yield, minimum-wall callouts and remaining-wall after expanding deserve extra attention on the enquiry. Put the cut list, U-bend preference, and end preparation on the order so mill and stock lengths can be mixed efficiently.
Equivalent Grades
Equivalence language around XM-19 tube is often looser than a high-strength heat-exchanger purchase order can afford. ASTM A213 Grade XM-19 / UNS S20910 is the governing designation for this article; Nitronic 50 is the common trade name; EN and JIS cross-references exist as approximate wrought names but are not automatic substitutes on an A213 mill test certificate. When a datasheet says “equivalent to XM-19,” confirm which product standard, tensile/hardness table, and heat-treatment clause the mill will actually certify.
| Designation | Notes |
|---|---|
| ASTM A213 / A213M Grade XM-19 | Governing ASTM seamless boiler / HX tube product standard for this article |
| UNS S20910 | Unified number listed in the stainless chemistry table |
| Nitronic 50 | Common trade name — does not replace XM-19 / S20910 on the MTC |
| ASME SA-213 XM-19 | Separate ASME Code Book adoption — dual-mark only when the PO asks |
| Related plate / bar | A240 flat product and A479 bar in the same UNS family — order each form under its own product standard |
Dual A213/SA-213 marking is a purchase-order option, not a claim that the two standards are one document. Compare TP316/L and higher-PREN grades on their own ASTM A213 pages before swapping chemistry on corrosion alone while ignoring the 100/55 ksi strength story that usually drove the XM-19 selection.
Heat Treatment and Delivery Condition
XM-19 under ASTM A213 is furnished solution treated at a minimum of 1900 °F [1040 °C], then quenched in water or cooled rapidly by other means at a rate sufficient to prevent carbide reprecipitation. That heat-treatment row applies to both cold-finished and hot-finished seamless tube. Nitrogen-strengthened austenitics need a thorough solution treatment so the N–Mn–Nb–V balance stays in solid solution rather than precipitating as unwanted phases that can cut toughness or corrosion resistance.
Cold-finished versus hot-finished is a process and dimensional route, not a substitute for the anneal. Delivery condition for SHH STEEL XM-19 is solution annealed and pickled (or bright annealed by agreement), with heat-treatment temperature and quench method stated on the EN 10204 3.1 certificate. Straightening after anneal is controlled so cold work does not undermine the annealed properties at the ends.
When Supplementary Requirement language for intergranular-corrosion capability (commonly ASTM A262 Practice E) is ordered, the corrosion test report travels with the heat-treatment record. Do not treat a verbal “annealed Nitronic” note as proof that the 1900 °F minimum and rapid cool were applied — ask for temperature and quench method on the MTC.
Corrosion Resistance
XM-19’s chromium–molybdenum–nitrogen balance gives a passive film that generally resists chloride pitting and crevice attack better than TP304 and often competes with or exceeds TP316 in many chloride-leaning waters, while the nitrogen floor also supports the high yield. That does not make S20910 a seawater duplex or a 6-Mo superaustenitic: for aggressive seawater, sour, or high-PREN duties, open A213 UNS S31254 or other high-alloy grades on the hub rather than stretching XM-19 beyond its intended band.
Carbon ≤0.06% helps as-welded intergranular resistance relative to standard-carbon 18-8, but contractual A262 Practice E testing still belongs on the purchase order when IGC capability is a project requirement. ASTM A213 itself does not publish a corrosion-rate or PREN table for XM-19; selection remains engineering judgment against fluid, temperature, velocity, and inspection philosophy. SHH STEEL will not market XM-19 as a universal substitute for 316L or for superaustenitics — match the chemistry and the 100/55 ksi strength story to the datasheet.
Applications of A213 XM-19 Tube
XM-19 seamless tube under A213 is chosen when high yield strength and solid chloride performance must share one austenitic tube grade — marine and coastal heat exchangers, high-pressure process HX, and boiler or superheater circuits where the code allowables for S20910 earn their keep. It is not a lean Mn–N cost play like TP201/TP202, and it is not an H-grade creep specialist like TP304H. The table below pairs typical application areas with a selection note.
| Application area | Typical use of XM-19 tube | Selection note |
|---|---|---|
| Marine / coastal heat exchangers | Seamless HX tubes where chloride resistance and high yield both matter | Confirm seawater vs brackish; step to S31254 if PREN must go higher |
| High-pressure process HX | Thinner-wall designs that exploit the 55 ksi yield floor | Qualify filler and tubesheet joint for the strength level |
| Boiler / moderate superheater | Seamless tube where A213 documentation and S20910 allowables apply | Not an H-grade grain-size substitute — open TP304H/TP347H for creep framing |
| Chemical process coolers | Tube-side or shell-side circuits with mixed corrosives and pressure | Review Mo and N against the actual fluid, not only the grade name |
| General high-strength austenitic tube | Where A213 seamless tube is preferred over pipe product forms | Do not substitute A312 pipe paperwork for A213 tube acceptance |
For classic molybdenum austenitic without the 100/55 ksi floor open A213 TP316L; for creep-range H-grade boiler tubing open A213 TP304H or A213 TP347H on the A213/A213M hub.
Weldability
XM-19 tube welds with matching or near-matching nitrogen-bearing austenitic fillers selected to preserve strength and corrosion resistance in the joint — commonly ER209 / E209-family or other S20910-matched consumables under a qualified WPS. Do not default to ER308L simply because it is familiar; a soft deposit undercuts the 55 ksi design intent that usually drove the base-metal selection. Heat input, interpass limits, and post-weld cleaning remain the fabricator’s responsibility under the applicable boiler or pressure-vessel code — A213 governs the seamless tube product, not the shop weld procedure.
Because A213 XM-19 is seamless, there is no mill longitudinal weld to radiograph the way welded pipe standards describe. Focus inspection language on tube integrity (hydro or NDE of each length), tube-to-tubesheet joint quality (including strength matching), and any contractual corrosion test on the base metal. Specify end preparation and surface finish on the tube PO when orbital or clean-service joins are planned. When tubesheet cladding or overlay chemistry differs from S20910, write the joint design and filler explicitly on the fabrication package.
Surface Finishes
Standard mill delivery for ASTM A213 XM-19 is solution annealed and pickled, leaving a clean matte finish suitable for most boiler and heat-exchanger tube duty. Bright annealing under protective atmosphere produces a smoother reflective surface used on some clean-process lines and must be called out because it changes the heat-treatment route. Light polish or specified Ra on the bore or OD is a commercial or service-center operation on top of A213 product, not automatic with the grade stamp.
Marine and fouling-sensitive exchangers sometimes quote an Ra maximum on the bore — put it on the tube purchase order with its own acceptance language and sampling plan. SHH STEEL stencils grade and heat treatment as standard requirements; polish, special OD grind, and passivation after fabrication remain commercial extras unless the contract says otherwise. Order end preparation together with finish so receiving inspection shares one acceptance language.
Inspection and Testing
Base ASTM A213 testing for XM-19 includes heat analysis (with Nb, V, Mo, and N reported), tension tests to the Table 4 floors (100/55 ksi), hardness tests to the Table 4 maximum (250 HBW / 25 HRC), flattening and flaring tests on a lot basis, and either hydrostatic testing or nondestructive electric testing of each length. The manufacturer may choose hydro versus NDE unless the purchase order fixes the method. Marking includes the ASTM designation, grade, size, heat number, and other clause-required data.
Supplementary Requirements commonly added on XM-19 tube orders are summarized below. Invoke them by number or clear purchase-order wording.
| Option | Purpose |
|---|---|
| Product analysis | Confirms chemistry on finished tube — useful when N, Mo, Nb, or V sit near band edges |
| Intergranular corrosion | A262 Practice E (or agreed practice) as a contractual Supplementary Requirement |
| Minimum vs average wall | States which wall basis the size callout uses — critical when walls are thinned for yield |
| Fixed hydro or NDE method | Removes manufacturer’s option when the end user mandates one route |
| Third-party inspection / EN 10204 3.2 | Witnessed testing and certificate when the project requires it |
Ask the mill to state lot identity clearly on the certificate so hardness and tension specimens map cleanly to the bundle you receive, and verify that Nb and V appear on the chemistry block before releasing the heat.
Packaging and Shipping
XM-19 tube leaves SHH STEEL bundled, capped or end-protected, and tagged for export or domestic delivery according to the length mix and bend form on the order. Bundle tags repeat the ASTM A213 grade (XM-19 / S20910), OD × wall (or BWG), heat number, and PO reference so site receiving can check the shipment without opening every certificate packet first. U-bent tubes need extra cradle or case protection so bend radii and legs are not distorted in transit.
Export packing can be bare bundles, wrapped bundles, or wooden-cased lengths for bright-annealed, polished, or small-bore material. We ship under the Incoterms on the order acknowledgement — FOB, CFR, CIF, EXW, or other agreed terms. Inland trucking, bilingual destination marks, or project color coding for bundle tags should be stated on the enquiry beside the metallurgical notes.
Why Choose SHH STEEL
SHH STEEL treats ASTM A213 XM-19 as a product standard with enforceable chemistry (including Nb, V, Mo, N), tensile, hardness, heat-treatment, and marking rules — not as a catalogue nickname for “any Nitronic tube.” The MTC reports the full ladle chemistry and the Table 4 tensile/hardness set (100/55 ksi, 250 HBW / 25 HRC); the stencil carries seamless tube identity under A213; and dual A213/SA-213 marking is offered only when requested.
We keep the high-strength conversation honest. If the duty is chloride-driven but does not need 55 ksi yield, we open A213 TP316 / A213 TP316L. If PREN must go higher still, we open A213 UNS S31254. If creep-range H-grade boiler framing is the real need, we open A213 TP304H or A213 TP347H. The A213/A213M hub is organized grade by grade under ASTM, seamless tube only.
Lead times combine near-term stock lengths with mill schedules; we say which is which on the quotation. Cut-to-length, U-bending, polish, and third-party inspection are defined extras. The tube that arrives should match the ASTM callout the engineer wrote, with paperwork a third-party inspector can read without translation.
Supply Capability
SHH STEEL can supply ASTM A213 XM-19 stainless steel tube against the edition and finish route named on your enquiry. The capability table below summarizes the sizes, finishes, and documents we regularly quote for this grade, followed by the Stock / Available sizes map buyers ask for when they need a quick sense of what to enquire against.
| Item | SHH STEEL capability for XM-19 |
|---|---|
| Standard | ASTM A213 / A213M (dual SA-213 marking on request) Grade XM-19 / UNS S20910 |
| Product form | Seamless only — cold-finished and hot-finished |
| Size | Typical OD × min wall (or average wall) in the A213 usual band; other diameters by agreement |
| Wall / gauge | Minimum wall or average wall; BWG / gauge callouts accepted on enquiry |
| Length | Cut-to-length for HX / boiler bundles; mill random by agreement; U-bends on enquiry |
| Finish | Annealed and pickled; bright annealed or light polish by agreement |
| Testing | Tension (100/55 ksi), hardness (max 250 HBW / 25 HRC), flattening, flaring, hydro or NDE per length; full ladle chemistry including Nb/V/Mo/N on MTC; product analysis / IGC on order |
| Documents | EN 10204 3.1 with full ladle chemistry; third-party inspection / 3.2 on request |
| Trade terms | FOB / CFR / CIF / EXW and other agreed Incoterms |
Stock / Available sizes
SHH STEEL quotes XM-19 tube against a practical stock-and-mill enquiry range rather than a frozen warehouse SKU list. The sizes below are OD × wall / BWG combinations buyers most often request when high-strength austenitic HX tube is on the datasheet; availability of any single line on a given week depends on mill drawing and our inbound schedule, so treat the table as a supply map for enquiry — not a guarantee of floor tonnage.
| Item | Typical stock / enquiry range for XM-19 |
|---|---|
| Outside diameter | 19.05, 25.4, 31.8, 38.1, 50.8, 63.5, 76.2 mm (and other HX/boiler ODs on enquiry; up through the usual A213 ~5 in. [127 mm] band) |
| Wall / BWG | BWG 10–18 class walls and metric min-wall equivalents; thinner walls exploiting 55 ksi yield by agreement after design review |
| Common OD × wall examples | 25.4 × 1.65 mm; 25.4 × 2.11 mm; 31.8 × 2.11 mm; 38.1 × 2.77 mm; 50.8 × 2.77 mm; 63.5 × 2.77 mm — illustrative, confirm min vs average wall |
| Length | Cut lengths for exchanger bundles; U-bends and straight random lengths on enquiry |
| Special | Non-standard OD/wall, bright anneal, polished bore, matched filler notes, and dual A213/SA-213 marking — confirm on enquiry |
When you send an enquiry, list OD × wall (or BWG), wall basis, cold-finished or hot-finished preference, quantity or cut list, required marking (A213 alone or dual A213/SA-213), filler expectations for tubesheet joints, and any Supplementary Requirements. We reply with what we can ship from near-term stock versus what needs a mill run, without inventing fake warehouse codes or tonnage claims.
Send the size list, finish route, quantity or cut lengths, required marking, Supplementary Requirements, and destination on one enquiry. We will confirm chemistry (including Nb/V/Mo/N), tensile, and hardness against the stainless chemistry table and Table 4, state what ships from near-term availability versus mill production, and keep the offer aligned with ASTM A213 / A213M. Related grades such as A213 TP316L, A213 TP304, and A213 UNS S31254 sit on the same hub when the datasheet steps beyond XM-19.
FAQ
-
Is ASTM A213 the same as ASME SA-213 for XM-19?
- No. ASTM A213 / A213M is the ASTM International product specification for seamless boiler, superheater, and heat-exchanger tubes; ASME SA-213 / SA-213M is the separate ASME Code Book adoption of that grade text. Chemistry, tensile, and hardness floors align closely for a given referenced edition, but they remain two independent standards. Dual-mark A213/SA-213 tube only when the purchase order asks for both names on the stencil and MTC.
-
Does ASTM A213 XM-19 include welded or HCW tube?
- No. ASTM A213 covers seamless tube only. There is no WLD or HCW manufacturing type under this product standard the way ASTM A312 describes pipe. The process choice for XM-19 under A213 is cold-finished versus hot-finished seamless tube, plus the heat-treatment and testing clauses of the ordered edition.
-
What is the UNS number and chemistry of ASTM A213 XM-19?
- XM-19 is UNS S20910 (trade name Nitronic 50). Melting limits include C ≤0.06%, Mn 4.0–6.0%, P ≤0.045%, S ≤0.030%, Si ≤1.00%, Cr 20.5–23.5%, Ni 11.5–13.5%, Mo 1.50–3.00%, N 0.20–0.40%, Nb 0.10–0.30%, and V 0.10–0.30%. Product-analysis limits apply only when ordered, typically from A480 Table A1.1 via A1016. Confirm the ordered A213 edition for the exact stainless-table number.
-
What tensile and hardness floors does A213 Table 4 set for XM-19?
- Table 4 for XM-19 lists 100 ksi [690 MPa] tensile strength, 55 ksi [380 MPa] yield strength, 35% elongation, and a hardness maximum of 250 HBW / 265 HV or 25 HRC. Hardness tests are part of lot acceptance under A213. That yield floor is nearly twice TP316’s 30 ksi under the same product standard — match filler and joint design to the strength level.
-
XM-19 vs TP316 — which A213 tube should I order?
- Order XM-19 when the datasheet needs the 100/55 ksi Table 4 floor plus Cr–Mo–N chemistry, and the code allowables for S20910 earn their keep. Order TP316 / TP316L when classic molybdenum austenitic paperwork at 75/30 (or 70/25 for L) is enough and the high-strength story is not required. They are not interchangeable stamps — chemistry, tensile, and hardness rows all differ.
-
Is Nitronic 50 the same as ASTM A213 XM-19?
- Nitronic 50 is the common trade name for the UNS S20910 chemistry family. On an A213 mill test certificate and stencil, the governing designation is Grade XM-19 / UNS S20910 under ASTM A213 / A213M. Write the ASTM grade on the purchase order; treat the trade name as a commercial alias, not a substitute product standard.
-
Minimum wall vs average wall — which should I order for A213 XM-19?
- Order minimum wall when the design and datasheet are written around a guaranteed minimum thickness after tolerance — especially important when walls are thinned to exploit the 55 ksi yield. Order average wall only when the purchase order explicitly allows it and the designer has accepted that basis. Put the wall basis on the enquiry before the mill selects A1016 tolerance tables.
-
What heat treatment does ASTM A213 require for XM-19?
- XM-19 is solution treated at a minimum of 1900 °F [1040 °C] and then water quenched or rapidly cooled to prevent carbide reprecipitation. Both cold-finished and hot-finished seamless tube follow that heat-treatment requirement. Ask the mill to state anneal temperature and quench method on the EN 10204 3.1 certificate so receiving inspection can clear the heat without chasing verbal confirmations.
-
What filler should I use for XM-19 tube-to-tubesheet welds?
- Use a matching or near-matching nitrogen-bearing austenitic filler (commonly ER209 / E209-family or other S20910-matched consumables) under a qualified WPS so the joint can support the 55 ksi design intent. Defaulting to ER308L often undercuts the strength that drove the base-metal selection. A213 governs the tube product, not the shop weld procedure — qualify the WPS under the applicable code.
-
Hydrostatic test vs NDE — which do I get on XM-19 tube?
- ASTM A213 requires each tube to be hydrostatically tested or nondestructively electrically tested. The manufacturer may choose the method unless the purchase order fixes one. Neither route is an informal upgrade over the other inside the product standard. State the preferred method on the enquiry if your end user or inspector mandates hydro only or a named NDE technique.
-
Can you dual-certify ASTM A213 and ASME SA-213 XM-19?
- Yes when the heat and testing support it. Dual A213/SA-213 marking is available when the purchase order requests both independent standards on the stencil and MTC. Spell the required marking on the enquiry so the heat is selected and documented correctly, with Nb, V, Mo, and N all reported on the chemistry block.
Conclusion
ASTM A213 XM-19 / UNS S20910 (Nitronic 50) is the high-strength nitrogen-strengthened seamless stainless steel tube grade for boiler, superheater, and heat-exchanger service when a 100/55 ksi Table 4 floor and Cr–Mo–N–Nb–V chemistry share one datasheet. SHH STEEL supplies cold-finished and hot-finished seamless tube in the usual OD × wall / BWG band, solution annealed, tested to Table 4 tensile and hardness limits, and documented on EN 10204 3.1 certificates with full ladle chemistry — with dual SA-213 marking only when the order asks for that separate ASME standard. For sister grades and stock-oriented size discussions, start from the A213/A213M hub, then send your OD × wall list, wall basis, filler notes, and marking requirements so we can align mill and near-term availability to the ASTM callout.
Contact: admin@steelspecs.com