EN 10297-2 1.4512 Seamless Stainless Steel Tube

EN 10297-2 1.4512 / X2CrTi12 seamless stainless general-purpose tube (409 / Ti-stabilised 12%Cr), ferritic corrosion-resisting, cast analysis per EN table, ambient Rp0.2 min 210 MPa, Rm min 380 MPa, A long. min 25%, delivery +A. SHH STEEL can produce and supply with EN 10204 3.1 MTCs and ordered Annex A finishes.
Grade
1.4512 / X2CrTi12 (409 / Ti-stabilised 12%Cr — body alias)
Standard
EN 10297-2
Product form
Seamless tube for mechanical and general engineering purposes, delivery +A as applicable
Size
~6–219 mm OD × ~0.5–20 mm wall within family practice; other sizes by agreement
Share:
Overview
Chemical Composition
Mechanical Properties
Seamless Tube Manufacture
Specification
Equivalent Grades
Heat Treatment
Corrosion Resistance
Applications
Weldability
Surface Finishes
Inspection and Testing
Packaging and Shipping
Why Choose SHH STEEL
Supply Capability
FAQ
Conclusion

What is EN 10297-2 1.4512 Seamless Stainless Steel Tube

Mechanical and general engineering projects that need seamless stainless tube under a European product standard look to EN 10297-2:2005 — Part 2 of EN 10297 — rather than a PED pressure Part 5 page or an ASTM tubing habit alone. 1.4512 / X2CrTi12 sits in the ferritic corrosion-resisting tables. When a drawing still says “409 seamless tube” without a European product standard, EN 10297-2 1.4512 is the general-purpose seamless designation that carries the Ti-stabilised 12%Cr analysis into the MTC. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

Mill path for 1.4512: thin-to-medium wall seamless OD common in exhaust and light mechanical catalogues. SHH STEEL can produce and supply X2CrTi12 under EN 10297-2 1.4512 as seamless tube for mechanical and general engineering — not as a silent dual of EN 10216-5 pressure acceptance unless that standard is also ordered. Typical supply includes Annex A finish symbols, cut lengths by agreement, and EN 10204 3.1 certification. Use thread: automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres.

On the shop floor people still say “409 / Ti-stabilised 12%Cr tube,” yet that commercial alias does not select cast chemistry, seamless process route, delivery-condition heat treatment, or optional tests. The purchase order has to name EN 10297-2, 1.4512, the Annex A process/surface symbol, and any Options so the mill applies the correct analysis, piercing/drawing route, heat treatment, mechanical floors, and marking. This number’s job on seamless general-purpose duty is: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified. Typical duties include automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres. Design caution: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice. Caution thread: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice.

Scope discipline matters: 1.4512 under EN 10297-2 is seamless general-purpose tube. Sister pages for pressure seamless (EN 10216-5) or welded pressure (EN 10217-7) share chemistry families but not acceptance text. Order the standard that the drawing and regulatory file actually require. Role reminder for 1.4512: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

Inside this seamless general-purpose series, compare EN 10297-2 1.4002, EN 10297-2 1.4016, EN 10297-2 1.4510. Hub: EN 10297-2.

Chemical Composition of EN 10297-2 1.4512

Cast window focus for 1.4512: Every 1.4512 heat under EN 10297-2 must meet the cast (ladle) analysis for X2CrTi12 in the ferritic corrosion-resisting chemical tables. Product analysis may be agreed as an Option with permissible deviations as tabulated in the standard. SHH STEEL reports actual cast values on the EN 10204 document and does not sell unproven “equivalent” chemistry under this steel number. Commercial alias 409 / Ti-stabilised 12%Cr is body text only. Corrosion thread: chromium passive film for dry and mildly wet atmospheres; Ti ties carbon/nitrogen to limit grain-boundary chromium depletion in many as-welded light duties.

The composition table that follows lists public BSSA EN 10297-2 cast limits for 1.4512 / X2CrTi12. Treat secondary web catalogues as non-contractual; the purchased EN 10297-2:2005 text wins if anything conflicts. Ranges are shown where the standard publishes min/max rather than a single maximum. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

Steel C Si Mn P S Cr N Ti
1.4512 / X2CrTi12 ≤0.030 ≤1.00 ≤1.00 ≤0.040 ≤0.015 10.5–12.5 ≤0.030 6×(C+N)–0.65

Mechanical Properties of EN 10297-2 1.4512

Ambient floors focus for 1.4512: Table mechanical floors for 1.4512 / X2CrTi12 are delivery-condition values at room temperature, not elevated-temperature design allowables. Summary: Rp0.2 min 210 MPa, Rp1.0 min 220 MPa, Rm min 380 MPa, longitudinal elongation min 25%. SHH STEEL reports actual tensile results on the EN 10204 3.1 document for the ordered test unit. Family: ferritic corrosion-resisting. Caution thread: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice.

Delivery condition Rp0.2 min (MPa) Rp1.0 min (MPa) Rm (MPa) A long. min (%) A trans. min (%) IGC
+A 210 220 380 min 25 25 No

Ambient values from EN 10297-2:2005 Tables 6–9 for 1.4512 / X2CrTi12. Guideline solution/anneal band (Annex B): 750–850 °C; cooling: air, water or gas.

Seamless Tube Manufacture for EN 10297-2 1.4512

Seamless route narrative for 1.4512: Ferritic seamless 1.4512 (X2CrTi12) is produced from pierced or extruded hollows, then annealed (+A) to restore ductility after hot or cold finishing. Grain-growth control during anneal matters for toughness and forming. Annex A process-route symbols for seamless 1.4512 include HFD (hot finished, heat treated, descaled), CFD (cold finished, heat treated, descaled), CFA (cold finished bright annealed), CFG (ground), and CFP (polished). Combinations may be agreed at enquiry. Weld thread: low heat input, matching or overlying ferritic fillers; post-weld anneal when the order demands restored ductility after heavy forming.

Ferritic 1.4512 ships annealed (+A). Annex B points at roughly 750–850 °C with air, water or gas cooling. Do not expect austenitic elongation floors after cold expansion without a forming trial. Forming and expansion trials should respect ferritic elongation floors rather than austenitic shop habits. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

State leak-tightness, hydrostatic, eddy-current, or ultrasonic Options explicitly for 1.4512. General-purpose seamless acceptance is not identical to EN 10216-5 TC1/TC2 pressure regimes; copy the Options list you need onto the EN 10297-2 order. Size context for 1.4512: thin-to-medium wall seamless OD common in exhaust and light mechanical catalogues. Use thread: automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres.

Dimensions and Tolerances for EN 10297-2 1.4512

Dimensional order line for 1.4512: SHH STEEL aligns OD × wall, tolerance class, and process-route symbol for 1.4512 / X2CrTi12 before rolling or drawing slots are locked. Thin-to-medium wall seamless od common in exhaust and light mechanical catalogues. Use thread: automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres.

For precision mechanical duty on 1.4512, cold-finished CFA/CFD routes are the usual conversation; heavier structural or heat-service walls may stay hot-finished HFD. Agree eccentricity and straightness when the assembly stack-up is tight. Size hint for 1.4512: thin-to-medium wall seamless OD common in exhaust and light mechanical catalogues. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

Equivalent Grades for EN 10297-2 1.4512

Equivalence talk for 1.4512 starts with X2CrTi12: 1.4512 / X2CrTi12 is the EN 10297-2 designation for this chemistry as seamless general-purpose tube. Commercial alias 409 / Ti-stabilised 12%Cr appears in body text only — not in the H1. ASTM/ASME pages that share a related chemistry are different product standards with different wall bases, mechanical tables, and tests. Confirm before treating them as interchangeable. Inside this seamless general-purpose series, compare sisters 1.4002, 1.4016, 1.4510. Hook for buyers still using only the 409 / Ti-stabilised 12%Cr alias: lock EN 10297-2 1.4512 on the order line. Caution thread: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice.

Heat Treatment and Delivery Condition for EN 10297-2 1.4512

Ferritic 1.4512 ships annealed (+A). Annex B points at roughly 750–850 °C with air, water or gas cooling. Do not expect austenitic elongation floors after cold expansion without a forming trial. Weld thread: low heat input, matching or overlying ferritic fillers; post-weld anneal when the order demands restored ductility after heavy forming.

Fabrication HT reminder for 1.4512 (+A): For 1.4512, purchasers who need verified IGC after fabrication should say so with the applicable Option and method (EN ISO 3651-2 framing). Mill +AT or +A of the tube does not automatically clear a fabricator’s as-welded joint without procedure control. Delivery framing on the certificate for 1.4512 should match +A. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

Corrosion Resistance of EN 10297-2 1.4512

Corrosion behaviour of EN 10297-2 1.4512 tracks its ferritic corrosion-resisting balance: chromium passive film for dry and mildly wet atmospheres; Ti ties carbon/nitrogen to limit grain-boundary chromium depletion in many as-welded light duties. This standard’s IGC column (where present) refers to EN ISO 3651-2 testing under the tabulated conditions — it is not a blanket warranty for every process medium. Design caution remains: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice Corrosion thread: chromium passive film for dry and mildly wet atmospheres; Ti ties carbon/nitrogen to limit grain-boundary chromium depletion in many as-welded light duties.

SHH STEEL does not invent PREN, CPT, or CCT marketing digits for 1.4512. When a purchaser supplies a qualified corrosion dossier, we match chemistry and delivery condition to that dossier; otherwise we stay with tabulated standard facts and plain-language family guidance. Family filing for 1.4512 is ferritic corrosion-resisting. Caution thread: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice.

Applications of EN 10297-2 1.4512 Tube

Applications of EN 10297-2 1.4512 tube centre on mechanical and general engineering rather than PED pressure shells: automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres. Role summary: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified. When the same chemistry is required as pressure seamless tube, open the EN 10216-5 sister page where that steel number exists. Use thread: automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres.

It is the wrong first choice when a welded product form is mandatory (use EN 10296-2 or EN 10217-7 as applicable), when PED pressure seamless acceptance is locked to EN 10216-5 alone, or when the medium clearly needs a sister such as 1.4002. Primary application sketch: automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

Weldability of EN 10297-2 1.4512

1.4512 / X2CrTi12 is welded as a fabricator joint on mechanical assemblies even though the tube product itself is seamless under EN 10297-2. Shop guidance: low heat input, matching or overlying ferritic fillers; post-weld anneal when the order demands restored ductility after heavy forming. Mill heat treatment of the tube does not replace qualified welding procedures on site joints. Weld thread: low heat input, matching or overlying ferritic fillers; post-weld anneal when the order demands restored ductility after heavy forming.

When IGC testing of welded coupons is specified, align the EN ISO 3651-2 method with the grade’s tabulated expectations and the purchaser’s Option list. SHH STEEL can coordinate mill-supplied weld data only when it is part of the agreed scope. Filler/shop note for 1.4512: low heat input, matching or overlying ferritic fillers; post-weld anneal when the order demands restored ductility after heavy forming. Caution thread: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice.

Surface Finishes for EN 10297-2 1.4512

Finish selection for 1.4512 on Annex A: For 1.4512, pick CFA when residual scale is unacceptable on visible mechanical assemblies; pick CFG/CFP only with a written OD/ID scope and roughness target. Descaled HFD/CFD remains the workhorse engineering finish. Alias reminder: commercial talk may say 409 / Ti-stabilised 12%Cr, but the finish symbol still belongs on the EN 10297-2 line. Use thread: automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres.

Protective agreements for 1.4512 cover sleeved bright tube, desiccant in sealed crates on long ocean routes, and dry indoor storage after arrival. Polished CFP surfaces ship with non-metallic rub strips so bundle-to-bundle contact cannot print fretting marks. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

Inspection and Testing for EN 10297-2 1.4512

Inspection lot framing for 1.4512 in ferritic corrosion-resisting: Specific inspection applies to EN 10297-2 1.4512 as agreed on the order. Cast analysis is reported per heat. Room-temperature tensile testing follows the standard’s test-unit rules for the ordered delivery condition. Dimensional checks cover OD, wall, length, and the agreed tolerance class. Keep 1.4512 heat identity intact from cast through bundle tag. Weld thread: low heat input, matching or overlying ferritic fillers; post-weld anneal when the order demands restored ductility after heavy forming.

When EN ISO 3651-2 IGC is ordered on 1.4512, the method letter and acceptance sit on the Option line and the MTC. Hardness, flattening, ring expanding, or drift tests run only when invoked. Marking carries manufacturer identity, OD × wall, EN 10297-2, 1.4512 or the steel name, cast/code, and inspection correlation. Use thread: automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres.

Packaging and Shipping for EN 10297-2 1.4512

Dispatch note for 1.4512 (409 / Ti-stabilised 12%Cr body alias only): SHH STEEL ships EN 10297-2 1.4512 in end-protected, size-sorted bundles or wooden crates with waterproof wrap on export routes. Descaled HFD/CFD engineering finishes still get caps and separators; carbon-steel strapping never sits bare on the stainless OD. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

Marking and identity for 1.4512: When cut lengths and special ends are part of the 1.4512 order, those pieces are segregated and capped before wrap so warehouse mixing cannot silently swap walls or finishes. Packing lists cross-reference heat numbers to bundle IDs. Finish-sensitive packing for 1.4512 follows the Annex A symbol on the order. Use thread: automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres.

Bundle cards for 1.4512 repeat the heat identity used on the EN 10204 3.1 certificate. SHH STEEL can email packing photos before sailing when the project file needs them, and will re-pack if a bright finish shows transit rub before handover. Caution thread: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice.

Why Choose SHH STEEL

Why 1.4512 with SHH STEEL — role: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified. SHH STEEL can produce and supply X2CrTi12 as EN 10297-2 1.4512 seamless tube with honest scope boundaries. General engineering seamless acceptance is what this page sells; pressure, welded-pressure, and welded-general-purpose sisters are separate standards with separate MTCs. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

Grade advice stays practical for 1.4512. If the duty needs a sister chemistry, we point to 1.4002, 1.4016, 1.4510. Design caution for this number: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice We answer medium questions with sister pointers rather than overselling a single chemistry. Contact the engineering desk with OD × wall, delivery condition, and medium notes before the cast is locked. Caution thread: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice.

Supply Capability

SHH STEEL can produce and supply EN 10297-2 1.4512 seamless tube to the edition, delivery condition, Annex A symbol, and Options on your enquiry. Capability and Stock / Available sizes notes below are a first-pass map for X2CrTi12, not a promise of frozen tonnage. Use thread: automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres.

Item Capability
Standard EN 10297-2:2005 seamless general-purpose
Steel 1.4512 / X2CrTi12
Product form Seamless tube (HFD / CFD / CFA / CFG / CFP)
Delivery condition +A
Documents EN 10204 3.1 (Options as ordered)
Typical enquiry OD ~6–219 mm (other by agreement)
Typical enquiry wall ~0.5–20 mm within family practice (other by agreement)

Stock / Available sizes

Stock / Available sizes for EN 10297-2 1.4512: enquiry band commonly spans instrumentation-to-process OD with walls suited to this grade. This is not a frozen SKU tonnage table — heat availability of X2CrTi12 and finishing slots for the Annex A symbol set the real promise date. Size context: thin-to-medium wall seamless OD common in exhaust and light mechanical catalogues. Duty thread: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.

Cut lengths, bevels or special ends, IGC Options, and dual RFQs against 1.4002, 1.4016, 1.4510 are routine for 1.4512. Catalogue charts only sanity-check OD × wall — contractual acceptance stays with EN 10297-2. SHH STEEL can produce and supply pilot lengths when the schedule allows. Weld thread: low heat input, matching or overlying ferritic fillers; post-weld anneal when the order demands restored ductility after heavy forming.

FAQ

What is EN 10297-2 1.4512 seamless stainless steel tube used for?
EN 10297-2 1.4512 (X2CrTi12) is seamless tube for mechanical and general engineering — automotive exhaust components, muffler tubing, heat shields, and light structural or hydraulic lines in mildly corrosive atmospheres. It is not automatically PED pressure tube; when pressure seamless acceptance is mandatory, specify EN 10216-5 for the same chemistry where listed. Role summary: Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified.
Is EN 10297-2 1.4512 the same as EN 10216-5 1.4512?
Chemistry families may overlap, but acceptance differs. EN 10297-2 is seamless general-purpose / mechanical engineering; EN 10216-5 is seamless pressure. An EN 10297-2 MTC for 1.4512 does not clear PED pressure duties by itself. Dual orders must satisfy each standard’s mechanical and test regime.
What delivery condition applies to 1.4512 / X2CrTi12?
Delivery framing for 1.4512 is +A under the EN 10297-2 family tables. Guideline heat-treatment temperatures sit in Annex B near 750–850 °C with air, water or gas cooling. State the delivery condition on the purchase order so marking and the MTC match.
What Annex A finishes can SHH STEEL supply for 1.4512?
SHH STEEL can produce and supply HFD, CFD, CFA, CFG, and CFP routes for EN 10297-2 1.4512 when the mill can meet the ordered surface. Descaled HFD/CFD covers most engineering duties; CFA is bright annealed; CFG/CFP need a written OD/ID roughness scope. Carbon-steel strapping never contacts the stainless OD.
How does 1.4512 compare with sister grades 1.4002, 1.4016, 1.4510?
1.4512 / X2CrTi12 is filed as ferritic corrosion-resisting. Typical sisters discussed on the same RFQ are 1.4002, 1.4016, 1.4510. Design caution: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice Pick the sister when the medium or strength floor outgrows this number rather than stretching surface finish alone.
Can 1.4512 be welded even though the tube is seamless?
Yes — fabricator joints are common on mechanical assemblies. Shop guidance: low heat input, matching or overlying ferritic fillers; post-weld anneal when the order demands restored ductility after heavy forming. Mill heat treatment of the seamless tube does not replace a qualified WPS on site welds. For corrosive as-welded duty, confirm low-carbon, stabilisation, duplex ferrite control, or PWHT as applicable.
What tests should appear on the EN 10204 3.1 document for 1.4512?
Expect cast analysis, room-temperature tensile results for the ordered delivery condition, dimensions, and every Optional test actually performed (leak, hydrostatic, eddy current, ultrasonic, IGC). SHH STEEL does not print surrogate NDT lines. EN 10297-2 Options are not identical to EN 10216-5 TC1/TC2 pressure categories.
What size range can SHH STEEL quote for EN 10297-2 1.4512?
SHH STEEL can produce and supply enquiry-oriented OD × wall bands for 1.4512 — commonly instrumentation through mid-process sizes, with heavier walls by agreement. Size context: thin-to-medium wall seamless OD common in exhaust and light mechanical catalogues. Send the OD × wall list, Annex A symbol, and delivery condition for a firm acknowledgement. Stock / Available sizes on this page is an RFQ map, not a frozen tonnage catalogue.
Does commercial alias 409 / Ti-stabilised 12%Cr belong in the purchase-order H1?
No. On steelspecs.com product pages the H1 is the steel number only. Use 409 / Ti-stabilised 12%Cr in body text and BOM notes, but lock EN 10297-2 and 1.4512 on the order line so cast analysis, delivery condition, and Options are unambiguous. Silent alias substitution is a common root cause of wrong MTCs.
When should I choose duplex or Mo austenitic instead of 1.4512?
Move when chloride pitting, crevice attack, or SCC risk exceeds what ferritic corrosion-resisting practice can defend for the temperature and stress state. Caution for this number: not a chloride-service austenitic substitute — pitting and weld HAZ toughness stay limited compared with 18-8; keep wall and forming within ferritic practice Sister pointers: 1.4002, 1.4016, 1.4510. SHH STEEL will not invent PREN marketing digits — bring the medium data and we will map chemistry honestly.
Is EN 10297-2 1.4512 suitable for heat-resisting furnace duty?
Only the heat-resisting grades in Table 9 are first-choice furnace numbers. 1.4512 is filed as ferritic corrosion-resisting. If you need oxidising heat service, confirm whether 1.4749 / 1.4833 / 1.4845 / 1.4835 / 1.4876 / 1.4854 is the intended family before ordering a corrosion-resisting analysis. Conversely, do not force a heat-resisting number into aqueous chloride process duty without review.

Conclusion

EN 10297-2 1.4512 (X2CrTi12) is seamless stainless tube for mechanical and general engineering — Ti-stabilised 12%Cr ferritic seamless tube for exhaust-adjacent and mild mechanical duties where nickel cost is not justified. SHH STEEL can produce and supply it with the Annex A finish, delivery condition, and Optional tests named on your enquiry, documented on EN 10204 3.1 certificates. Sister grades often discussed alongside this number include 1.4002, 1.4016, 1.4510. For pressure seamless acceptance of the same chemistry family, see EN 10216-5 where listed. Email admin@steelspecs.com with OD × wall, delivery condition, and medium notes to start the quote.

Contact Us

Quality Steel Needed? Inquire for Offers

Need quality steel for your project? Inquire now to get tailored offers. Our team ensures quick responses, matching your needs with reliable steel solutions. Start your inquiry today.

    *

    *

    *

    *


    Related Products

    SHH STEEL Get Your Steel Quote—Inquire Now for Quick Response
    SHH STEEL Get Your Steel Quote—Inquire Now for Quick Response

      *

      *

      *

      *


      X