JIS G 3106 SM490 Steel Channel

JIS G 3106 SM490 steel channel is a Japanese welded-structure channel in the 490–610 N/mm² tensile class. The page covers SM490A, B, C, YA and YB, lists the JIS G 3192 Table 12 series, and gives heat analysis, yield tables and the 0 °C impact rules that apply above 12 mm.
Keywords
JIS G 3106 SM490 Steel Channel, SM490 channel, SM490B channel, JIS G 3192 channel, SM490C
Equivalent Grades:
SM490 H-beam (same material family); SS400 channel (same shape series, general-structure grade); Q355B channel; S355JR — comparisons only, not automatic substitutes.
Share:
General Description
Material Specification
Available Sizes of SM490 Steel Channel
Chemical Composition of SM490 Steel Channel
Mechanical Properties of SM490 Steel Channel
Delivery Conditions, Inspection and Identification
Weldability of SM490 Steel Channels
Shape Tolerances and Theoretical Mass
Applications and Service Limits
SM490 Compared with SS400, Q355B and S355JR
Near-Equivalents: Not Automatic Substitutes
Sourcing SM490 Steel Channels from SHH STEEL
FAQ
Conclusion

What is JIS G 3106 SM490 Steel Channel?

JIS G 3106 SM490 steel channel is a hot-rolled Japanese channel whose material grade is one of the SM490 qualities under JIS G 3106 — SM490A, SM490B, SM490C, SM490YA or SM490YB — and whose shape, mass and tolerances are ordered to JIS G 3192 Table 12. SM stands for rolled steel for welded structure, and 490 is the tensile-strength class (490–610 N/mm²). There is no suffixless grade in the standard called only “SM490”; the quality letter must be named on the order.

This page covers the SM490 family in channel form. The H-section sister is JIS G 3106 SM490 H-beam. A general-structure comparison on the same channel series is JIS G 3101 SS400 steel channel.

These bars are filed under steel channel profiles in the steel structural profiles category. They are designated H×B×t1×t2, for example 200×90×8×13. They are not GB/T 706 taper-flange channels, and they are not European UPN, UPE or PFC or American C or MC of a similar millimetre depth.

Material, Dimensions and the SM490 Quality Family

The purchase order and the inspection document should name, separately:

  • JIS G 3106 and its edition (this page uses the 2020 edition as the numeric basis; the edition named on the order governs), and the full quality symbol SM490A, SM490B, SM490C, SM490YA or SM490YB;
  • the JIS G 3192 channel designation (H×B×t1×t2);
  • any agreed heat-treatment suffix and any agreed Ceq or PCM limit.
Symbol Standard scope for sections (mm) Heat-analysis carbon, max (%) Charpy requirement in JIS G 3106:2020 (thickness > 12 mm)
SM490A ≤ 200 0.20 (t ≤ 50); 0.22 (50 < t ≤ 200) Not listed in Table 8. No standard impact test; do not infer one from the 490 tensile class.
SM490B ≤ 200 0.18 (t ≤ 50); 0.20 (50 < t ≤ 200) 27 J at 0 °C, V-notch, rolling direction.
SM490C ≤ 100 0.18 (t ≤ 100) 47 J at 0 °C, V-notch, rolling direction. This is not the same energy as SM490B.
SM490YA ≤ 100 0.20 (t ≤ 100) Not listed in Table 8. Higher yield than A/B/C, but still no standard impact test.
SM490YB ≤ 100 0.20 (t ≤ 100) 27 J at 0 °C, V-notch, rolling direction, with the higher YA/YB yield table.

The standard allows thickness to be displayed as t1 only, but several depths share the same H and B with different web and flange thicknesses. The full H×B×t1×t2 string avoids mixing those sections.

SM490 Steel Channel Sizes: JIS G 3192 Table 12

The table is the complete standard channel series in JIS G 3192:2024 Table 12: 16 sizes, from 75×40×5×7 to 380×100×13×20. The tabulated dimensions are representative; other section dimensions may be used by agreement. A Japanese channel is not a GB/T 706 model or a European UPN of similar depth. Not every mill rolls every designation in every SM490 quality.

Swipe horizontally to view all dimensions.

Designation (H×B×t1×t2) H (mm) B (mm) t1 (mm) t2 (mm) r1 (mm) r2 (mm) A (cm²) Mass (kg/m)
75×40×5×7 75 40 5 7 8 4 8.818 6.92
100×50×5×7.5 100 50 5 7.5 8 4 11.92 9.36
125×65×6×8 125 65 6 8 8 4 17.11 13.4
150×75×6.5×10 150 75 6.5 10 10 5 23.71 18.6
150×75×9×12.5 150 75 9 12.5 15 7.5 30.59 24.0
180×75×7×10.5 180 75 7 10.5 11 5.5 27.20 21.4
200×80×7.5×11 200 80 7.5 11 12 6 31.33 24.6
200×90×8×13.5 200 90 8 13.5 14 7 38.65 30.3
250×90×9×13 250 90 9 13 14 7 44.07 34.6
250×90×11×14.5 250 90 11 14.5 17 8.5 51.17 40.2
300×90×9×13 300 90 9 13 14 7 48.57 38.1
300×90×10×15.5 300 90 10 15.5 19 9.5 55.74 43.8
300×90×12×16 300 90 12 16 19 9.5 61.90 48.6
380×100×10.5×16 380 100 10.5 16 18 9 69.39 54.5
380×100×13×16.5 380 100 13 16.5 18 9 78.96 62.0
380×100×13×20 380 100 13 20 24 12 85.71 67.3

SM490 Chemical Composition (Heat Analysis)

The figures below are heat-analysis maxima from JIS G 3106:2020 Table 2. For these channels the relevant thickness is that at the test-piece location, ordinarily the flange t2, not the overall depth H. In the Table 12 series t2 ranges from 7 mm to 20 mm, so the carbon steps above 50 mm are kept for a thicker special section or a relocated specimen written on the order, not because a tabulated flange already sits in that band.

Symbol Thickness (mm) C max Si max Mn max P max S max
SM490A t ≤ 50 0.20 0.55 1.65 0.035 0.035
SM490A 50 < t ≤ 200 0.22 0.55 1.65 0.035 0.035
SM490B t ≤ 50 0.18 0.55 1.65 0.035 0.035
SM490B 50 < t ≤ 200 0.20 0.55 1.65 0.035 0.035
SM490C t ≤ 100 0.18 0.55 1.65 0.035 0.035
SM490YA / SM490YB t ≤ 100 0.20 0.55 1.65 0.035 0.035

Clause 7.2 Ceq and PCM tables in JIS G 3106:2020 apply to plates and sheets manufactured by a thermo-mechanical control process. They are not a default as-rolled channel CEV. If a Ceq or PCM limit is required on a section order, it must be agreed and stated on the certificate; no value is invented here.

SM490 Mechanical Properties: Yield, Tensile and 0 °C Impact

Tensile properties follow Table 7 of JIS G 3106:2020. Thickness is that at the location of the test pieces, ordinarily the flange t2. In the tabulated series t2 is 7 mm to 20 mm, so those rows sit in the first or second yield band when the flange is the test location. Later bands remain in the table for a thicker special section. Annex JB (leg length under 40 mm) does not apply: every Table 12 channel has a flange width B of 40 mm or more.

Thickness at the test-piece location (mm) Min. yield, SM490A/B/C (N/mm²) Tensile strength (N/mm²)
t ≤ 16 325 490–610
16 < t ≤ 40 315 490–610
40 < t ≤ 75 295 490–610
75 < t ≤ 100 295 490–610
100 < t ≤ 160 285 (A and B only) 490–610 (A and B only)
160 < t ≤ 200 275 (A and B only) 490–610 (A and B only)

SM490YA and SM490YB use a higher yield table, still in the 490–610 N/mm² tensile class, with a standard section scope of 100 mm or less:

Thickness at the test-piece location (mm) Min. yield, SM490YA/YB (N/mm²) Tensile strength (N/mm²)
t ≤ 16 365 490–610
16 < t ≤ 40 355 490–610
40 < t ≤ 75 335 490–610
75 < t ≤ 100 325 490–610

Elongation is as follows:

Thickness (mm) Test piece Min. elongation, A/B/C (%) Min. elongation, YA/YB (%)
t ≤ 5 No. 5 22 19
5 < t ≤ 16 No. 1A 17 15
16 < t ≤ 50 No. 1A 21 19
t > 40 No. 4 23 21

When impact testing applies (the symbols listed in Table 8, with thickness over 12 mm), the requirements are:

Symbol Test temperature (°C) Minimum absorbed energy (J) Test piece and direction
SM490A — Not specified in Table 8 —
SM490B 0 27 V-notch, rolling direction
SM490C 0 47 V-notch, rolling direction
SM490YA — Not specified in Table 8 —
SM490YB 0 27 V-notch, rolling direction

A lower test temperature may be agreed. An A or YA certificate does not demonstrate a 0 °C test, and a 27 J B result is not a 47 J C result. Some of the smaller tabulated flanges are 12 mm or thinner; clause 8.2 is written for thickness over 12 mm.

Delivery Conditions, Inspection and Identification

SM490 channels are commonly supplied as-rolled. Heat treatment, including normalizing or a thermo-mechanical control process, is used when agreed; any agreed suffix is added to the quality symbol. The inspection document should identify JIS G 3106 and its edition, the full quality symbol, the JIS G 3192 designation, heat analysis, and tensile results against the thickness at the test location, plus the Table 8 impact result for B, C or YB when that test applies. A plate or H-beam certificate does not, by itself, identify a channel.

Weldability of SM490 Steel Channels

SM490 is specified as a weldable rolled steel for welded structures. Preheat and consumable choice should use the certified heat analysis, any agreed Ceq or PCM, the actual thickness and the joint design. A CEV figure must not be read off a TMCP plate table as if it automatically applied to an as-rolled channel.

JIS G 3192 Shape Tolerances and Theoretical Mass

Shape, mass and tolerances belong to the ordered edition of JIS G 3192. Mass in the size table is the published theoretical figure. Millimetre tolerance tables are not reproduced here. Settlement on theoretical or weighed mass should follow the contract.

Applications and Service Limits

SM490 channels are used in welded frames, bracing and similar work where a Japanese welded-structure grade in the 490 N/mm² tensile class is named. Choose the quality letter for the impact or yield table actually required. They are not a silent substitute for JIS G 3101 SS400 steel channel, for a GB/T 706 channel, or for a European UPN in S355JR.

SM490 Compared with SS400, Q355B and S355JR

The comparisons below are an orientation only; they are not automatic substitutes.

Grade / designation Standard Relationship to SM490 channel Caution
SM490 H-beam JIS G 3106; dimensions JIS G 3192 Table 15 The same material family in H-section form. A channel designation is not an H-section. See JIS G 3106 SM490 H-beam.
SS400 channel JIS G 3101; dimensions JIS G 3192 Table 12 A general-structure comparison on the same channel series, at a lower tensile class and with no Charpy table. SS400 is not a welded-structure SM grade. See JIS G 3101 SS400 steel channel.
Q355B channel GB/T 1591; dimensions GB/T 706 A Chinese 355 MPa taper-flange channel often compared with the SM490 tensile class. The GB/T 706 model number is not a JIS H×B×t1×t2 designation. See GB/T 706 Q355B steel channel.
S355JR EN 10025-2; dimensions EN 10365 A European 355 MPa comparison, usually as UPN, UPE or PFC. JR, J0 and J2 are different impact qualities, and the shape systems differ. See EN 10025-2 S355JR H-beam for the European material class in H-section form.

Near-Equivalents: Not Automatic Substitutes

A near-equivalent is a starting point for a discussion, not a licence to swap certificates. If a project names SM490B or SM490C, keep that quality letter and JIS G 3192 on the order. The H-section sister is JIS G 3106 SM490 H-beam.

Sourcing SM490 Steel Channels from SHH STEEL

SHH STEEL supplies JIS G 3106 SM490 steel channels against a named designation list, the quality letter, the material edition and the inspection document type. Enquiries should state the H×B×t1×t2 designations, the quality (A, B, C, YA or YB), cut lengths or mill lengths, any processing, and whether JIS G 3101 SS400 steel channel is acceptable on part of the list.

The size table is the standard series, not a claim that every designation is rolled in every quality. Once the list is clear, a quotation can be prepared against the stated edition and certificate.

SM490 Steel Channel FAQs

Is there a single grade called just SM490?
No. The standard uses SM490A, SM490B, SM490C, SM490YA and SM490YB. A and YA have no standard Table 8 impact test. B and YB require 27 J at 0 °C when testing applies; C requires 47 J at 0 °C. YA and YB use a higher yield table.
Which thickness is used for yield and impact on a channel?
Thickness is that at the location of the test pieces, ordinarily the flange t2, not the depth H. In the Table 12 series t2 ranges from 7 mm to 20 mm. Impact testing, when it applies, is written for thickness over 12 mm.
Does a Ceq table apply to every SM490 channel?
No default as-rolled channel CEV is published in the same way as the TMCP plate tables in clause 7.2. If a Ceq or PCM limit is required on a section order, it should be agreed and written on the certificate.
Which edition of JIS G 3106 is used on this page?
The numeric tables use JIS G 3106:2020. Dimensional sizes use JIS G 3192:2024 Table 12. A later edition of either standard may be named on the order; the ordered edition governs.

Request a Quotation for JIS G 3106 SM490 Steel Channel

JIS G 3106 SM490 steel channel is a welded-structure channel in the 490–610 N/mm² tensile class. Nominate the JIS G 3192 designation (H×B×t1×t2), the quality letter (A, B, C, YA or YB), JIS G 3106:2020 or the edition on the order, and the inspection document type. Send the size list, quality, edition, certificate type and any processing notes; SHH STEEL will review the package and quote accordingly.

Contact Us

Quality Steel Needed? Inquire for Offers

Need quality steel for your project? Inquire now to get tailored offers. Our team ensures quick responses, matching your needs with reliable steel solutions. Start your inquiry today.

    *

    *

    *

    *


    Related Products

    SHH STEEL Get Your Steel Quote—Inquire Now for Quick Response
    SHH STEEL Get Your Steel Quote—Inquire Now for Quick Response

      *

      *

      *

      *


      X